Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

PARAMETER PRODUK

Keterangan
PERMINTAAN PENAWARAN

Keterangan

Overview of Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

Trafo terendam oli adalah jenis trafo listrik yang inti dan belitannya terendam dalam minyak isolasi.. Minyak ini memiliki dua fungsi utama: ia bertindak sebagai isolator yang sangat efektif antara bagian konduktif dan sebagai pendingin untuk menghilangkan panas yang dihasilkan selama pengoperasian. Transformator ini kuat, dapat diandalkan, dan sangat efisien, menjadikannya pilihan standar untuk jaringan distribusi dan transmisi tenaga listrik tegangan tinggi, biasanya dipasang di luar ruangan di gardu induk.

Features of Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

  • Pendinginan yang Efektif: Oli isolasi secara efisien menyerap panas dari inti dan belitan serta memindahkannya ke sirip radiator, memungkinkan sirkulasi alami atau paksa dan kapasitas kelebihan beban yang lebih tinggi.
  • Isolasi Unggul: Minyak memberikan kekuatan dielektrik yang jauh lebih baik dibandingkan udara, memungkinkan desain yang lebih kompak untuk peringkat tegangan tertentu dan melindungi terhadap korsleting.
  • Konstruksi Kuat: Dirancang untuk jangka panjang, operasi yang andal (sering 25-30 bertahun-tahun) di lingkungan luar ruangan yang keras.
  • Kapasitas Kelebihan Beban: Dapat menangani kelebihan daya sementara dengan lebih baik daripada transformator tipe kering karena massa termal dan sifat pendinginan oli.
  • Sistem Proteksi: Dilengkapi dengan tangki konservator (untuk memungkinkan ekspansi minyak), istirahat (untuk menyerap kelembapan dari udara), dan relay pelindung (Relai Buchholz) untuk deteksi kesalahan internal.
  • Hemat Biaya: Umumnya lebih ekonomis untuk aplikasi daya tinggi dibandingkan trafo tipe kering.

Specifications of Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

These oil-filled instrument transformers handle 50Hz or 60Hz power systems. They work with three-phase electricity. Their main job is changing high system voltages or currents into lower, safer levels. This allows accurate measurement and protection. Meters and relays use these lower levels safely.

The transformer core and windings sit inside a strong steel tank. We fill this tank with special high-efficiency insulating oil. This oil does two important jobs. It cools the transformer parts. It also provides excellent electrical insulation. This oil stops sparks and electrical breakdown inside the transformer. Its high efficiency means it transfers heat very well. This keeps the transformer running cooler. Cooler operation extends the transformer’s life.

We build these transformers tough. The tank is sealed. This keeps the insulating oil clean and dry. Clean, dry oil is vital for good performance and long life. These transformers meet strict safety standards. They are reliable for critical jobs.

Key specifications define their performance:
Voltage Class: They match standard system voltages like 11kV, 33kV, or higher.
Rated Burden: They can power connected devices like meters up to a specific load, measured in VA (Volt-Amperes).
Accuracy Class: They guarantee measurement precision within defined limits (e.g., Class 0.5 or Class 1.0).
Insulation Level: They withstand high voltage surges specified by standards like BIL (Basic Impulse Level).
Oil Type: They use high-quality, high-efficiency mineral insulating oil.
Frequency: They work on both 50Hz and 60Hz power systems.

You find these transformers in substations and power plants. They connect directly to high-voltage lines. They feed instruments and protection relays. Their job is crucial for monitoring power flow and safeguarding equipment.

Applications of Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

Oil immersed instrument transformers handle high voltage power systems safely. These 50/60Hz transformers work with three-phase electricity. They use special insulating oil inside their tank. This oil is highly efficient. It cools the transformer parts. It also provides strong electrical insulation. This keeps everything safe and reliable.

These transformers step down high voltages and currents. They make them safe for meters and protective relays. This is their main job. They connect directly to the high voltage lines. They are built tough for outdoor use. They handle weather, dirt, and temperature changes well. You see them in substations and power plants.

For metering, they give accurate voltage and current signals. This accuracy is vital. Utility companies bill customers based on this data. The transformers perform reliably under normal load conditions. They ensure precise energy measurement over time. Their design focuses on stable performance.

For protection, they provide signals to protective relays. These relays detect faults like short circuits. When a fault happens, relays need fast, dependable signals. These transformers deliver that. They help isolate the fault quickly. This protects expensive equipment. It also keeps the wider power grid stable. Their insulation withstands high voltage surges.

Industrial plants use these transformers too. They monitor power usage inside large facilities. They feed critical data to control systems. Their robust construction handles industrial environments. They resist vibration and electrical noise.

The transformers feature high-grade steel cores. These cores have low magnetic losses. This design saves energy. The windings use quality copper or aluminum. This minimizes electrical losses. The insulating oil has excellent dielectric strength. It prevents internal electrical breakdown. The tank is sealed tightly. This stops moisture and air from getting inside. It keeps the oil clean and effective.

These transformers meet strict international standards. They comply with IEC and IEEE requirements. They are tested for safety and performance. Tests include measuring accuracy, temperature rise, and impulse withstand (BIL levels). They guarantee reliable operation for years. They are a key part of modern power infrastructure.

Profil Perusahaan

PDDN Fotoelektron Technology Co., Ltd. adalah salah satu perusahaan terkemuka di bidang teknologi elektronika daya dan produk daya, yang terlibat penuh dalam pengembangan inverter surya, transformator, pengatur tegangan, lemari distribusi, thyristor, modul, dioda, pemanas, dan perangkat elektronik atau semikonduktor lainnya. Kami akan berkomitmen untuk menyediakan layanan berkualitas tinggi kepada pengguna, produk yang efisien dan layanan penuh perhatian.

Ia menerima pembayaran melalui Kartu Kredit, T/T, Serikat Barat, dan Paypal. PDDN akan mengirimkan barang ke pelanggan di luar negeri melalui FedEx, DHL, melalui laut, atau melalui udara. If you want high-quality Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil, silakan kirimkan pertanyaan kepada kami; kami akan berada di sini untuk membantu Anda.


Metode Pembayaran

L/C, T/T, Serikat Barat, Paypal, Kartu Kredit dll.


Pengiriman

Melalui laut, melalui udara, dengan mengungkapkan, sebagai permintaan pelanggan.


Kondisi Penyimpanan

1) Simpan di lingkungan kering pada suhu kamar.

2) Hindari lembab dan suhu tinggi.

3) Gunakan segera setelah membuka kantong kemasan bagian dalam.

5 FAQs of Oil Immersed Instrument Transformer 50/60HZ Power Transformer With 3 Phase Three Phases Utilizing High Efficiency Insulating Oil

What does this oil-immersed instrument transformer do?
It safely steps down high voltage and high current levels in power systems. It’s for measuring electricity use accurately or protecting equipment. People install them in substations and industrial plants.

Is it safe around fire?
Ya, it uses special high-efficiency insulating oil. This oil resists catching fire very well. The transformer tank is strong steel. It keeps the oil sealed inside securely.

Where can people install this transformer?
You can put it indoors or outdoors. The design works for both places. It handles tough weather conditions fine. Make sure the spot has good airflow around the transformer body.

Does it need much maintenance?
Check the oil level and look at its condition regularly. The strong steel tank helps protect the internal parts. This usually means less maintenance work over time. Follow the maker’s schedule for oil tests.

Why choose this oil type?
The high-efficiency insulating oil cools the transformer windings effectively. It also insulates much better than older oils. Better insulation and cooling mean the transformer wastes less energy. This saves money on electricity.

PERMINTAAN PENAWARAN

PERMINTAAN PENAWARAN