Leverancier van elektronische componenten | Transformatoren, Inductoren, Omvormers
PRODUCTPARAMETERS
Beschrijving
Overview of 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class.
100/5Een EPOXYHARS 20VA HOOGSPANNING SPLIT CORE Stroomtransformator 5P20 Klasse. is precision instruments designed for accurate measurement and reliable protection in high-voltage electrical systems. Ze schakelen hoge primaire stromen veilig terug naar gestandaardiseerd, secundaire uitgangen op laag niveau, veilige monitoring mogelijk maken, meting, en bediening via aangesloten apparaten. Essentieel voor krachtoverbrenging, verdeling, en industriële toepassingen, onze transformatoren zorgen voor de systeemveiligheid, efficiëntie, en stabiliteit.
Features of 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class.
Hoge nauwkeurigheidsklasse: Nauwkeurig ontworpen voor betrouwbare metingen in meet- en beveiligingscircuits.
Robuuste isolatie: Geavanceerde isolatiematerialen (bijv., epoxyhars, olie-geïmpregneerd) zorgen voor betrouwbaarheid en veiligheid op lange termijn onder hoge diëlektrische spanning.
Breed stroombereik: Verkrijgbaar in verschillende verhoudingen om tegemoet te komen aan uiteenlopende toepassingsvereisten.
Laag vermogensverlies: Geoptimaliseerd kernontwerp voor minimaal energieverlies, verbetering van de algehele systeemefficiëntie.
Uitstekende lineariteit: Superieure prestaties onder een breed scala aan bedrijfsomstandigheden.
Duurzame constructie: Gebouwd om zware omgevingsomstandigheden te weerstaan, inclusief vocht, vervuiling, en temperatuurschommelingen.
Specification of 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class.
This existing transformer steps high electrical currents safely. It steps down huge currents to smaller sized, handige graden. The proportion is 100 amps primary to 5 amps additional. This basic output deal with many defense relays and meters. Its split-core style is a significant benefit. You do not require to disconnect the primary power cable. Simply open up the core, secure it around the conductor, and shut it. Setup is rapid and prevents pricey downtime. Safety and security improves considerably.
The transformer body utilizes high-grade epoxy material. This material supplies exceptional electrical insulation. It secures against high voltages successfully. The material likewise supplies strong resistance to dampness, stof, and extreme chemicals. This makes sure trusted performance in hard environments. It avoids inner parts from damages. Long-lasting stability is ensured.
This design has a 20VA problem ability. It can supply sufficient power to connected tools. This consists of relays and meters. Precision is vital for protection systems. This transformer meets the 5P20 accuracy course. The ‘5’ indicates the optimum composite error is 5% at its ranked accuracy limitation primary current. The ’20’ suggests the precision restriction factor is 20. It remains accurate even throughout severe mistake currents up to 20 times its rated worth. Relays get specific information for appropriate operation.
The split-core style fits retrofits and upgrades. It fits existing setups quickly. No wire cutting is needed. Maintenance checks end up being simpler as well. The robust epoxy housing needs marginal care. It endures resonance and temperature level changes well. Utilize this transformer for dependable current dimension and security in high voltage systems. It makes sure security and accuracy for your electrical devices.
Applications of 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class.
This 100/5A epoxy material split-core current transformer is built challenging for precise measurement and protection in high-voltage systems. Its 20VA power rating means it deals with linked gadgets accurately. The split-core design is its large advantage. You can clip it around live conductors. This prevents cutting wires or shutting down power. Installation is fast and safe.
It’s ranked 5P20 course. This is crucial for security circuits. During a short circuit fault, the current can increase extremely high. The 5P20 score ensures the transformer output remains exact within 5% error, even when main present hits 20 times its typical level (2000A for this 100A CT). Safety relays require this exact signal to trip breakers rapidly and protect against damage.
The durable epoxy resin casing gives exceptional electric insulation. It guards against moisture, stof, chemicaliën, and physical impacts. This makes the transformer suitable for requiring atmospheres. You find it in switchgear panels, onderstations, power distribution cupboards, en planten. It functions dependably outdoors and indoors.
Its primary job is feeding present signals to tools. It powers energy meters for exact payment and power surveillance. It supplies protective relays for detecting overloads and brief circuits. It offers input for power top quality analyzers inspecting harmonics and disturbances. It connects to SCADA systems for remote surveillance and control. It interfaces with data loggers tape-recording power usage fads.
The high insulation degree makes certain security when functioning near high voltages. The epoxy real estate stops monitoring and flashover. The split core conserves considerable time and cost throughout retrofit or maintenance projects. You do not require special tools or downtime. This current transformer supplies reliable efficiency where safety and precision issue a lot of. It’s a functional option for metering and defense jobs approximately 100A.
Bedrijfsprofiel
PDDN Foto-elektron Technologie Co., Ltd. is een van de toonaangevende ondernemingen op het gebied van vermogenselektronicatechnologie en energieproducten, dat volledig betrokken is bij de ontwikkeling van omvormers voor zonne-energie, transformatoren, spanningsregelaars, verdeelkasten, thyristoren, modules, diodes, verwarmers, en andere elektronische apparaten of halfgeleiders. We zullen ons inzetten om gebruikers hoogwaardige kwaliteit te bieden, efficiënte producten en attente service.
Het accepteert betaling via creditcard, T/T, Westelijke Unie, en PayPal. PDDN verzendt de goederen via FedEx naar klanten in het buitenland, DHL, over zee, of door de lucht. If you want high-quality 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class., Stuur ons alstublieft vragen; wij zullen hier zijn om u te helpen.
Betaalmethoden
L/C, T/T, Western Unie, Paypal, Creditcard enz.
Verzending
Over zee, door de lucht, per expresse, zoals klanten vragen.
Opslagomstandigheden
1) Bewaren in een droge omgeving bij kamertemperatuur.
2) Vermijd vocht en hoge temperaturen.
3) Gebruik onmiddellijk na het openen van de binnenverpakking.
5 FAQs of 100/5A EPOXY RESIN 20VA HIGH VOLTAGE SPLIT CORE Current Transformer 5P20 Class.
This 100/5A epoxy resin split core current transformer handles high voltage systems. It provides 5P20 accuracy. Hier vindt u veelgestelde vragen:
Wat is het belangrijkste voordeel van het gesplitste kernontwerp?
The split core lets you install it without shutting down the power. You clamp it directly around the live conductor. This saves significant time and avoids costly downtime during installation or maintenance.
Why is epoxy resin used?
Epoxy resin provides excellent electrical insulation. It protects the internal components from high voltages. The resin also shields against moisture, stof, en barre omgevingsomstandigheden, ensuring long-term reliability and safety.
What does the 5P20 accuracy class mean?
5P20 means the transformer stays within 5% error when the current reaches 20 times its rated value (so 100A x 20 = 2000A). This high accuracy under fault conditions is critical for protective relaying systems needing precise trip signals.
Where is this current transformer typically used?
Its main use is in protective relaying for high voltage equipment. Je vindt het in onderstations, power generation plants, and large industrial facilities. It feeds accurate current signals to protective relays during normal operation and faults.
What does the 20VA rating mean?
20VA is the maximum burden (laden) this transformer can handle on its secondary side. You connect measurement devices like meters or relays here. Ensure the total connected load doesn’t exceed 20VA. Overloading causes inaccurate readings and potential damage.
VRAAG EEN OFFERTE AAN
GERELATEERDE PRODUCTEN

Hoge kwaliteit LA-10 5-40A 0,2-0,5/10P 10/15VA Semi-gesloten door-muur hoogspanningsstroomtransformator voor binnen
Speciale isolator voor Chinese laagspanningstransformator Fabrikant

Control House s Power High Voltage Dry Type Current Transformer

Hoogspanningsstroomtransformator LZZB9-10S Stroomverbruik Casting Pijler Koperen spoel Driefasig 240V Ingang 400V 380V 415V 200V

Olie-ondergedompelde elektrische stroomverdelingstransformator 50KVA 100KVA 150KVA 200KVA 250KVA 300KVA 400KVA 450KVA 500KVA 20KV S11