Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage
JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage is an electrical transformer that uses air or solid insulation (such as epoxy resin or vacuum pressure impregnation) to cool and insulate its core and windings. Unlike liquid-filled transformers, it contains no oil or liquid coolant, making it a safer, more environmentally friendly choice for applications where fire safety and minimal environmental impact are critical.
Features of JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage
- Fire Safety: Non-flammable and self-extinguishing, eliminating the risk of oil fires or spills.
- Environmentally Friendly: Contains no toxic liquids, posing no risk of soil or water contamination.
- Low Maintenance: Does not require regular testing, filtering, or replacement of liquid coolant.
- High Reliability: Robust construction with excellent short-circuit strength and resistance to thermal cycling.
- Installation Flexibility: Can be installed directly in the load center (indoors or outdoors with an enclosure), reducing cable costs and space requirements.
Specifications of JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage
This JDZ9-35 interior pillar kind single-phase dry-type voltage transformer gauges high voltage for security and dimension. It’s developed for indoor electric systems. The dry-type design indicates no oil. This makes it more secure and cleaner. The column shape is compact and easy to install in switchgear.
It utilizes top notch epoxy material for insulation. This resin spreading offers exceptional security. It guards versus dampness, dust, and contamination very well. This makes certain trustworthy long-term operation inside switch cupboards. The building is durable and maintenance-free.
The transformer deals with primary voltages rated at 27.5 kilovolts or 35 kilovolts. It tips this high voltage down. The secondary output is a conventional reduced voltage of 220 volts. This reduced voltage is risk-free for connecting meters and relays. The conventional input link is 10 kilovolts.
It provides different capacity alternatives: 60 volt-amperes, 250 volt-amperes, or 500 volt-amperes. You select the capability based on your connected load needs. The device meets high precision standards, normally course 0.5 or class 0.2. This precision is important for right billing and system defense.
Its main job is precise voltage change. It securely isolates measurement circuits from the high voltage line. This transformer is essential for energy metering systems. It shields relay gadgets in power circulation networks. It fits perfectly in substations and industrial plants. Utilize it any place exact voltage tracking is called for inside your home.
Applications of JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage
This JDZ9-35 indoor pillar voltage transformer safely tips down high voltage for dimension and protection. It handles a 10kV input voltage. It offers a conventional 220V outcome. This outcome is easy and secure for meters and relays to use. The transformer is rated for systems up to 27.5 kV or 35kV. It has different capacity ratings: 60VA, 250VA, and 500VA. You choose the capability based upon the amount of tools you connect. The dry-type design means no oil. This makes it much safer and cleaner for indoor electric rooms. It avoids unpleasant leaks. Its insulation is resin-based. This is reliable and maintenance-free. The major work is precise voltage measurement. It feeds power to voltmeters. It likewise powers power meters. This takes place in substations and power plants. Factories utilize it also. It gives the voltage signal required for kilowatt-hour metering. Payment depends upon this accuracy. Safety relays need steady voltage signals. This transformer supplies them. Relays utilize it to find issues like overvoltage or undervoltage. Then they can journey breakers. This secures pricey tools. It attaches straight to high-voltage lines. It securely isolates the dimension circuits. Professionals don’t function directly with unsafe voltages. The 220V result is typical. It collaborates with usual surveillance tools. Its small column form fits nicely in switchgear panels. It saves space in control cabinets. You mount it indoors only. Exterior conditions would damage it. This transformer is a key component of risk-free power system operation. It guarantees dependable tracking and control.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of JDZ9-35 Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer 27.5/35KV 60/250/500VA 10KV Input 220V Output Voltage
What does the JDZ9-35 transformer do?
This transformer lowers high voltage. It steps down voltage for measurement or protection devices. It takes high voltage electricity. It makes it safe for meters and relays. The output is 220V. This voltage is easy for standard equipment to use.
Why does the nameplate show 27.5/35KV?
The nameplate shows two voltages. Both are correct. The transformer works at either 27.5kV or 35kV. This depends on your specific power system setup. Check your system requirements. Use the correct connection point.
What does 60/250/500VA mean?
This number is the capacity rating. It shows the transformer’s power handling ability. The transformer has different accuracy levels. Accuracy depends on the load connected. At 60VA load, it meets its highest accuracy class. At 250VA load, accuracy is lower but still good. At 500VA, it reaches its maximum capacity. Do not exceed 500VA. Exceeding capacity causes errors. It can also damage the transformer.
Can I install this transformer outdoors?
No. This transformer is for indoor use only. The “Indoor Pillar Type” design confirms this. Outdoor conditions are different. Moisture, dust, and temperature extremes harm it. Install it inside a clean, dry building. Ensure proper ventilation around it.
What are the input and output voltages?
The input voltage connects to the high voltage side. This is rated for 10kV systems. The output voltage is a standard 220V. This 220V output feeds your meters or protection relays. Connect the wires correctly. Wrong connections cause failure. They create safety hazards. Always follow the wiring diagram.
REQUEST A QUOTE
RELATED PRODUCTS
TCS-30MM Waterproof Encapsulated Split Core Power Transformer 100/5A 150/5A Frequency 50Hz For Transformer Substation
220V 24V 12V 5V High Frequency Power Transformer
Factory Direct s Customizable Capacity Epoxy Resin Dry-Type Transformer High-Efficiency Dry Transformer
High Voltage of 10kV and Below JSZW3-3,6,10A,B Dry-Type Power Transformer
MV&HV transformers High Efficiency 15MVA Three-Phase HV Power Transformer 20kV/35kV-110kV With OLTC For 60Hz Frequency