Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V
This IEC 60076 certified power transformer is built for dangerous locations. It uses oil immersion for reliable cooling and containment. Its core design prevents explosions. This makes it safe for hazardous areas with flammable gases or dust. The transformer meets strict international safety standards.
It operates on standard 50Hz frequency. The primary winding handles 6KV input voltage. Multiple secondary output coils provide different voltages. You get 200V, 208V, 415V, and 380V outputs. This flexibility supports various equipment needs in one unit. The design ensures stable voltage delivery under load.
Heavy-duty materials construct the tank and core. This provides excellent mechanical strength. The oil serves dual purposes. It cools the windings effectively. It also suppresses potential internal arcs. Sealed bushings prevent oil leaks. They maintain the explosion-proof integrity. Robust terminals ensure secure connections.
Safety certifications are critical. This transformer carries IECEx and ATEX approvals. It is suitable for Zone 1 and Zone 2 hazardous environments. Rigorous testing confirms its safety performance. It withstands internal faults without external ignition. Reliability is paramount in these settings.
Installation requires adherence to specific guidelines. Only qualified personnel should handle it. Proper grounding is essential. Regular oil checks and maintenance are mandatory. This ensures long-term safe operation. The transformer enables power distribution safely in chemical plants, refineries, mines, and similar high-risk facilities.
Applications of IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V
This IEC 60076 explosion-proof oil immersed power transformer is built for dangerous places. It handles 50Hz power. The input voltage is 6KV. Multiple output coils give different voltages. You get 200V, 208V, 415V, and 380V outputs. This flexibility is key for complex setups.
Safety is the main point here. Hazardous areas have flammable gases or dust. Normal transformers can spark and cause explosions. This transformer prevents that. Its design is explosion-proof. The entire unit is sealed inside a very strong tank. This tank contains any internal spark or fire. It stops the hazard from escaping into the dangerous area outside.
The transformer core and windings sit inside special oil. This oil does two big jobs. First, it cools the transformer very well. Transformers get hot during operation. Good cooling is vital for long life and stability. Second, the oil helps stop sparks. It quenches any electrical arcs that might form inside. This adds another safety layer.
Construction follows strict IEC 60076 standards. These rules ensure reliability and safety. The tank walls are thick. All joints are welded tight. Special seals prevent oil leaks. Bushings for the input and output cables are also explosion-proof. Every part is made tough for harsh environments. It resists corrosion and physical damage.
Having multiple secondary coils is a big advantage. Different equipment often needs different voltages. You might power motors at 415V and control circuits at 200V. This transformer provides all these voltages in one unit. It simplifies your power distribution. You avoid needing extra transformers. This saves space and reduces installation costs. It also makes maintenance easier.
Performance is reliable. The oil immersion ensures stable operation. Voltage regulation is good. Power delivery is consistent. This transformer keeps your critical processes running safely. It minimizes downtime risks. It is a dependable solution for oil refineries, chemical plants, mining sites, and similar locations.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of IEC 60076 Explosion-Proof Oil Immersed Power Transformer Hazardous Areas 50Hz 6KV Multiple Output Coils 200V 208V 415V 380V
What exactly is this transformer?
It is a power transformer built for hazardous locations. The transformer uses oil for cooling and insulation. It steps down 6KV high voltage to safer lower voltages. Outputs include 200V, 208V, 380V, and 415V. It runs at the common 50Hz frequency. Its design prevents explosions in flammable atmospheres.
Why is it called “explosion-proof”?
The transformer tank is incredibly strong. It can contain any internal explosion. Even if a fault creates sparks inside, the tank won’t rupture. Flames or hot gases cannot escape to ignite the surrounding hazardous atmosphere. This containment is key for safety in zones with explosive gases or dusts.
Which safety standards does it meet?
This transformer strictly follows the IEC 60076 standard. IEC 60076 covers power transformers generally. The explosion-proof construction also meets standards for hazardous area equipment. These standards ensure reliable, safe operation where ignition risks exist. Compliance is mandatory for such environments.
What are the different output voltages for?
The multiple output coils provide flexibility. They deliver common low voltages like 200V, 208V, 380V, and 415V. This lets you connect various equipment directly. You avoid needing extra step-down transformers on site. It simplifies power distribution in the hazardous location.
Where is this transformer typically used?
Use it anywhere flammable substances are present. Common places include oil refineries, chemical plants, paint spray booths, and grain handling facilities. Any Zone 1 or Zone 2 hazardous area needing reliable power benefits from this transformer. It powers motors, lighting, and control systems safely.
REQUEST A QUOTE
RELATED PRODUCTS
Whole High Quality Customizable 1000KVA 50/60HZ Low Loss and Low Noise Oil Immersed Transformer
35KV Medium And High Voltage Transformer SCB10 Dry-type Transformer 50/60Hz Electrical Equipment Transformer
220kv Oil-immersed Low Loss 200 Mva Power Transformer
High Efficiency Oil-Immersed Three-Phase Transformer 10KV 8000kVA 10000kVA 12500kVA 16000kVA 20000kVA with 35KV Input Voltage
Professional 220KV Oil immersed Power Transformer Supplier – Product and Solution Introduction