Lieferant elektronischer Komponenten | Transformatoren, Induktoren, Wechselrichter
PRODUKTPARAMETER
Beschreibung
Overview of Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency
Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency is an enclosed, Bodennaher elektrischer Verteilungstransformator, der üblicherweise im Untergrund verwendet wird (Und) Energiesysteme. Es reduziert den primären Hochspannungsstrom (z.B., 15kV oder 25kV) auf eine niedrigere Sekundärspannung (z.B., 120/240V oder 480V) zur sicheren Verteilung in Wohnvierteln, Gewerbebauten, und Industrieparks. Es ist robust, Das abschließbare Stahlgehäuse macht es sicher für öffentliche Bereiche.
Features of Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency
Bodennahe Einfriedung: Ein gesperrt, manipulationssicher, wetterfester Stahlschrank, der die internen Komponenten schützt und die öffentliche Sicherheit gewährleistet.
Erdkabelverbindungen: Konzipiert für den einfachen Anschluss an die unterirdische Primärversorgung (Hochspannung) und sekundär (Niederspannung) Kabel über Fächer mit eingebauten Durchführungen.
Kompartimentierung: Separate, Isolierte Fächer für Hochspannungs- und Niederspannungskomponenten, Erhöhung der Sicherheit bei der Wartung.
Belüftung: Entworfen mit Luftschlitzen oder anderen Belüftungssystemen, um eine ordnungsgemäße Wärmeableitung vom Transformatorkern und den Spulen zu ermöglichen.
Hebeösen: Integrierte Hebeösen für einfache und sichere Montage und Austausch mittels Kran oder Hebezeug.
Manipulationssichere Hardware: Abschließbare Türen mit Spezialriegeln gegen unbefugten Zugriff.
Sicherungsschalter: Enthält häufig abgesicherte Trennschalter zum Schutz des Stromkreises und zur sicheren Isolierung.
Pad-Fundament: Auf einer Betonplatte installiert (“Pad-montiert”) einen Stall zu bieten, ebene Basis.
Specifications of Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency
These three-phase pad-mounted transformers handle heavy-duty power conversion. They tip down high voltage electricity for commercial and business usage. The systems can be found in two capability scores: 300kVA and 500kVA. They accept a high input voltage of 110kV. They deliver a much safer, functional outcome voltage of 440V. The operating regularity is common 50Hz.
Developed tough for exterior installment, these transformers rest straight on a concrete pad. Their robust steel rooms shield internal parts. This design stands up to harsh climate condition quickly. Tamper-proof building and construction is an essential attribute for safety and safety and security. Unauthorized accessibility is effectively avoided. The design also decreases risks to the general public and pets.
Innen, premium electrical steel creates the core. Premium copper or aluminum windings make sure efficient power transfer. These materials assure trusted performance for many years. Minimized energy losses suggest reduced operating expense gradually. The transformers satisfy strict effectiveness requirements. This translates to cost financial savings for the individual.
Trick specifications specify these versions. The input voltage score is 110,000 Volt (110kV). The output voltage offered is 440 Volt. Readily available power abilities are 300 Kilovoltampere (kVA) Und 500 Kilovoltampere (kVA). The system regularity is 50 hertz (Hz). Typical cooling is ONAN (Oil Natural, Luft natürlich). The enclosures supply high security versus dust and water access (IP ranking). The devices follow appropriate global safety guidelines. They appropriate for networks requiring reliable 50Hz power circulation. These transformers attach substations to regional power grids effectively. They deliver steady power to manufacturing facilities, große Strukturen, and various other centers. Maintenance access factors are made for solution employees. Oil levels and vital elements are conveniently checked.
Applications of Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency
Manufacturing facilities need trustworthy power distribution. This three-phase pad-mounted transformer delivers. It handles 300kVA or 500kVA capacity. It tips down high voltage power securely. Input voltage is 110kV. Outcome voltage is 440V. Regularity is 50Hz. These specifications suit requiring commercial settings.
These transformers are crucial for heavy equipment. Steel mills use them. Chemical plants rely on them. Big production centers depend upon them. They power motors, Heizungen, Kompressoren, and large handling lines. The 440V output works well for industrial devices. The 110kV input connects directly to the primary power grid. This stays clear of extra substations. It conserves area and price.
The pad-mounted style is useful. It rests on a concrete pad outdoors. This frees up valuable indoor factory room. It withstands challenging weather conditions. The unit shields interior parts. Es hält Schmutz fern, Nässe, and pets. This guarantees long service life. Upkeep accessibility is simple.
Built-in defense functions are critical. They monitor oil degrees and temperature level. They find interior mistakes rapidly. This stops major damages. It decreases expensive downtime. Factories require continuous operation. This transformer helps maintain things running. Its robust construction deals with high electric lots. It manages the heat generated during operation. Ambient temperature arrays are taken into consideration.
The 50Hz frequency matches conventional commercial power grids. This transformer integrates smoothly into existing systems. It supplies the secure, reduced voltage power factories need. Effectiveness is necessary for decreasing operating expense. This system is developed for optimal efficiency. It manages power losses efficiently. Dependability is non-negotiable in manufacturing facility settings. This transformer fulfills that demand. It sustains essential manufacturing procedures day after day. Selecting the right capacity (300kVA or 500kVA) depends on particular factory power requirements.
Unternehmensprofil
PDDN Photoelectron Technology Co., Ltd. ist eines der führenden Unternehmen im Bereich Leistungselektronik und Energieprodukte, die voll an der Entwicklung von Solarwechselrichtern beteiligt ist, Transformatoren, Spannungsregler, Verteilerschränke, Thyristoren, Module, Dioden, Heizungen, und andere elektronische Geräte oder Halbleiter. Wir werden uns dafür einsetzen, den Benutzern eine hohe Qualität zu bieten, effiziente Produkte und rücksichtsvoller Service.
Es akzeptiert Zahlungen per Kreditkarte, T/T, West Union, und Paypal. PDDN versendet die Waren über FedEx an Kunden im Ausland, DHL, auf dem Seeweg, oder auf dem Luftweg. If you want high-quality Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency, Bitte senden Sie uns Anfragen; Wir werden für Sie da sein.
Zahlungsmethoden
L/C, T/T, Western Union, Paypal, Kreditkarte usw.
Lieferung
Auf dem Seeweg, auf dem Luftweg, per Express, nach Kundenwunsch.
Lagerbedingungen
1) In einer trockenen Umgebung bei Raumtemperatur lagern.
2) Vermeiden Sie Feuchtigkeit und hohe Temperaturen.
3) Nach dem Öffnen des inneren Verpackungsbeutels sofort verwenden.
5 FAQs of Factory Three Phase Pad Mounted Transformer 300kva 500kva 440v Output 110kv Input 50hz Frequency
This transformer steps down voltage. Es dauert 110,000 Volt in. Es gibt aus 440 Volt. It handles large power loads. It is built for factories needing reliable three-phase power. Common sizes are 300kVA and 500kVA. Es läuft mit einer Frequenz von 50 Hz.
Was macht dieser Transformator??
It changes high voltage electricity to usable lower voltage. Es dauert 110,000 volts from the utility line. It supplies 440 volts for factory machines. Es treibt schwere Geräte sicher an.
Wo wird dieser Transformator verwendet??
Fabriken nutzen es. Warehouses use it. Big commercial buildings use it. Any place needing a lot of three-phase power at 440V uses it. Es steht draußen auf einer Betonplatte. It connects directly to the power grid.
Wie wird es installiert??
Es braucht eine starke Betonunterlage. The pad must be level. The pad must be the right size. Skilled electricians handle the wiring. They connect the high voltage cables. They connect the low voltage output cables. They must follow all safety rules. The utility company usually connects the high voltage side.
Wie bleibt es kühl??
It uses oil. Oil circulates inside. Oil absorbs heat from the coils. Heat moves to the tank walls. Air cools the tank surface. This is called ONAN cooling. It works well for this size transformer. It keeps the transformer running safely.
Welche Wartung ist erforderlich?
Überprüfen Sie regelmäßig den Ölstand. Suchen Sie nach Lecks. Überprüfen Sie die Temperaturanzeigen. Keep the area around it clear. Keep plants and debris away. Professionals should do detailed checks. Sie testen die Ölqualität. Sie prüfen Verbindungen. They look for any damage. Regular maintenance prevents problems. It keeps power flowing.
Fordern Sie ein Angebot an
VERWANDTE PRODUKTE

China Einphasen-Wechselstrom-SMPS-Elektrotransformator, Pad-montierter Kupferfolien-Mikrowellenofen-Eingang, Niederspannung 220 V, 110 V, 240 V

3750kVA-Transformator für Pad-Montage | 13.2kV bis 480V | Jetzt auf Lager – Installationsanleitung 24/7 Unterstützung

Kombinierter kastenförmiger Umspanntransformator für den Außenbereich, auf einer Unterlage montiert, mit 10 kV Eingang, 440 V/380 V/220 V, Ausgang 50/60 Hz Frequenz

10kv 500kva 630kva 1000kva American Direct Box Transformer Pad Mounted Transformers

110KV 40MVA-Leistungstransformator für Pad-Montage