Elektronesch Komponente Fournisseur | Transformers, Induktoren, Inverters
PRODUIT PARAMETER
Beschreiwung
Overview of 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A
1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A is critical switching equipment used in electrical systems of power plants and substations. Seng primär Funktioun ass d'Sécherheet vun héichspannt elektreschen Apparater an Ausrüstung während Ënnerhaltsaarbechten ze garantéieren an d'Spannung ze isoléieren. Et kann net benotzt ginn fir ofzeschneiden, Input, oder trennt Laaschtstroum a Kuerzschlussstroum. Et kann nëmme fir gewësse Schaltoperatioune benotzt ginn, déi keng staark Bogen generéieren - normalerweis a Verbindung mat Héichspannungsschalter benotzt fir d'Energieversuergung während Ënnerhalt ze isoléieren, suergt Sécherheetsschutz fir Ënnerhaltspersonal an Ausrüstung. No der Installatioun Plaz an der Zuel vun Isolatioun Sailen, si kënnen an Indoor Typ ënnerdeelt ginn, Outdoor Typ, eenzel Kolonn, duebel Kolonn, an dräi-Kolonn Zorte. Den elektresche System vu Kraaftwierker an Ënnerstatiounen ass entscheedend fir d'Sécherheet vum Ënnerhaltspersonal an Ausrüstung ze garantéieren.
Characteristics of 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A
“Sécherheetsgarantie während Ënnerhalt vun héich-Volt elektresch Apparater an Apparater: Dëst ass déi primär Funktioun vun Héichspannungsisolatiounschalter, déi d'Sécherheet vun Ausrüstung an Opérateuren während Ënnerhalt Aarbecht garantéieren kann.
Isolatioun Volt: Et spillt d'Roll vun der Isoléierspannung a kann net benotzt ginn fir Stroum ofzeschneiden oder ze verbannen, et kann och net benotzt ginn fir Kuerzschlussstroum ze briechen.
Nonarc Läschfunktioun: Et kann net benotzt ginn fir Stroum ofzeschneiden; dat ass, et huet keng Bogenläschfunktioun.
Multiple Zorte: Laut der Installatiounsplaz, et kann duerch Indoor an Outdoor Typen ënnerdeelt ginn. No der Zuel vun Isolatioun Saile, si kënnen an eenzel Kolonn ënnerdeelt ginn, duebel Kolonn, an Triple-Kolonn Typen. All Spannungsniveau huet fakultativ Ausrüstung.”
Specifications of 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A
This disconnector switch circuit breaker manages numerous electric setups. It operates in single-phase (1P), two-phase (2P), and three-phase (four-pole, 4P 3 Pole) systems. Its key voltage ratings are air conditioning 230 volts and a/c 400 volts. Choose the version fitting your particular circuit voltage demands.
Available present rankings are 80 Amps, 100 Amps, an 125 Amps. Select the appropriate amperage based upon your circuit’s load needs. Never exceed the switch’s rated existing. This tool combines two important safety features. It functions as a reputable breaker. It immediately cuts power throughout hazardous overloads or brief circuits. This protects wiring and connected devices from damages.
It also works as a durable disconnector or isolator switch. This function enables manual, secure power cut-off for maintenance. Operators can noticeably separate a circuit area. This ensures zero voltage exists downstream. Safety and security is vital during maintenance or repair services. The button gives clear ON/OFF indication. Its layout makes sure trusted procedure under normal problems. The robust construction guarantees long-lasting longevity. Installation is uncomplicated for certified electrical contractors. The system abides by global safety and security standards like IEC/EN 60947-3. This verifies its viability for seclusion use.
The switch terminals approve conventional conductor dimensions. Ensure tight, safe and secure links. Loose links create overheating and failure. Normal assessment is advised. Look for signs of damages or extreme warm. Change the device instantly if any concerns are discovered. Using the appropriate post setup is vital. Suit it to your system’s phase requirements. Utilizing the wrong kind threats breakdown and safety and security risks. Always de-energize the circuit before any kind of work. Confirm the lack of voltage using proper examination tools. This device is for certified workers only. Adhere to all local electrical codes and regulations purely.
Applications of 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A
This button deals with air conditioner power systems. It works for voltages as much as 230V single-phase or 400V three-phase. People call it a main switch, disconnector, isolator, or breaker. It does several crucial jobs safely.
Its major work is seclusion. It physically cuts the power. This is important for safety and security. Electricians need this when dealing with circuits. They transform this switch off first. It quits electricity flowing to the equipment. This avoids shocks or mishaps. It provides a clear break point everyone can see.
It likewise works as a primary button. People utilize it to transform power on or off for a whole area. This might be a structure, a machine room, or a large item of devices. It controls the main power feed. Operators utilize it for typical closures or start-ups.
The breaker component protects the electrical wiring. It journeys automatically if too much existing flows. This occurs during a short circuit or a heavy overload. It quits wires overheating. It stops fires and damages. The 80A, 100A, and 125A scores reveal the maximum present it handles before stumbling. You choose the ranking matching your wires and load.
Different post types exist for different circuits. A 1P switch manages one real-time wire. It’s common for easy single-phase circuits. A 2P switch cuts both live and neutral in single-phase systems. This is safer for complete seclusion. A 3P switch manages all three live cables in a three-phase system. A 4P switch deals with three live wires plus the neutral in three-phase systems. This offers full seclusion.
You find these buttons in lots of places. Residences use them as the main house button or for big appliances. Offices and stores utilize them for distribution boards feeding various locations. Factories count on them for hefty machinery control and security isolation. They are crucial in power circulation panels. They provide security, control, and defense.
Firma Profil
PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.
Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.
Bezuelmethoden
L/C, T/T, Western Union, Paypal, Kreditkaart etc.
Sendung
Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.
Stockage Konditiounen
1) Store an engem dréchen Ëmfeld bei Raumtemperatur.
2) Vermeiden Feuchtigkeit an héich Temperaturen.
3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.
5 FAQs of 1P 2P 4P 3 Pole AC230/400 Main Switch Function Disconnector Isolator Switch Circuit Breaker 80A 100A 125A
What exactly does this switch do?
It safely cuts power to electrical circuits. Think of it as a master off switch for equipment. It disconnects power completely for maintenance or emergencies. It also protects against overloads like a circuit breaker. So it does two jobs in one unit.
What do 1P, 2P, 4P mean?
These tell you how many wires it controls. 1P controls one live wire. 2P controls two wires, usually live and neutral. 3P controls three live wires. 4P controls three live wires and the neutral. Pick the one matching your system’s wiring.
What’s the 80A, 100A, 125A for?
That’s the amperage rating. It means the maximum current the switch can safely handle before tripping. You must choose a rating matching your circuit’s load. Using a switch rated too low is dangerous. Using one rated too high won’t protect properly.
Is this different from a regular circuit breaker?
Yes, a bit. It works like a breaker for overloads. But it’s also a certified disconnector. This means it creates a visible air gap when off. You see the physical break in the circuit. This is vital for safety during work on the equipment. Standard breakers don’t always show this gap.
Where would I install this switch?
Use it as the main power cutoff for machines, control panels, or distribution boards. It’s common in industrial settings, workshops, or large appliances. It lets you isolate power safely before servicing. Make sure it’s easily reachable in case of emergency.
Ufro engem ZITAT
Zesummenhang PRODUITEN

High Voltage 10KV Disconnector Load Break Switches BHA-10/630-20z U2 with Fuse Market Switch Disconnectors

s Versuergung GW4-40.5 400A 630A 1000A hv Disconnector

Chinese Fabréck Héichspannung RH-B 11KV 630A Silikon Gummi Keramik Power Isolator Disconnector Single Phase Isolator Switch

80A-400A Mini MSD with Fuse Battery Manual Service Disconnect Plug and Socket HV Electric Vehicle Connector

Factory High Voltage 12kV 630A Circuit Breaker Outdoor HV Vacuum Disconnect Load with 20ka Breaking Capacity