Ueleg ënnerdaach Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

PRODUIT PARAMETER

Beschreiwung
Ufro engem ZITAT

Beschreiwung

Iwwersiicht vun Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

En Ueleg-Taucht Transformator ass eng Zort elektreschen Transformator wou de Kär an d'Wicklungen an engem isoléierende Ueleg ënnergeet sinn. Dësen Ueleg déngt zwou primär Funktiounen: et handelt als héich effektiven Isolator tëscht konduktiven Deeler an als Kältemëttel fir d'Hëtzt, déi während der Operatioun generéiert gëtt, ze dissipéieren. Dës Transformatoren si robust, zouverlässeg, an héich efficace, mécht se de Standardwahl fir Héichspannungsverdeelung an Iwwerdroungsnetzwierker, typesch dobaussen an Ënnerstatiounen installéiert.

Features of Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

  • Effektiv Ofkillung: Den Isoléierueleg absorbéiert effizient Hëtzt aus dem Kär an de Wicklungen an iwwerdréit et op d'Heizkierperfinnen, erlaabt natierlech oder gezwongen Zirkulatioun a méi héich Iwwerlaaschtkapazitéit.
  • Superior Isolatioun: Den Ueleg bitt vill besser dielektresch Kraaft wéi Loft, erlaabt fir e méi kompakt Design fir eng bestëmmte Volt Bewäertung a Schutz géint kuerz Circuit.
  • Robust Konstruktioun: Entworf fir laangfristeg, zouverlässeg Operatioun (oft 25-30 Joer) an haarden Outdoor Ëmfeld.
  • Iwwerlaascht Kapazitéit: Kann temporär Kraaft Iwwerlaascht besser handhaben wéi dréchent Transformatoren wéinst der thermescher Mass an der Ofkillungseigenschaften vum Ueleg.
  • Schutz System: Equipéiert mat engem Conservator Tank (Ueleg Expansioun ze erlaben), Otemschwieregkeeten (fir Feuchtigkeit aus der Loft ze absorbéieren), a Schutzrelais (Buchholz relais) fir intern Feeler Detektioun.
  • Käschten-effikass: Allgemeng méi ekonomesch fir Héichkraaftapplikatiounen am Verglach mat dréchent Transformatoren.

Specifications of Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

This oil-immersed power transformer handles three-phase electrical systems. It comes in different power levels: 100kVA, 200kVA, and 400kVA. It works with various voltages like 6kV, 10kV an, 11kV an, and 25kV. De Kär benotzt héichwäerteg Siliziumstahl. This material cuts down energy losses significantly. The steel laminations are stacked tightly. This design minimizes wasted power.

Copper or aluminum conductors form the windings. These windings carry the electrical current. The windings are carefully arranged around the core. The entire assembly sits inside a strong steel tank. Dëse Tank ass mat speziellen Isoléierueleg gefüllt. The oil does two important jobs. It insulates the live parts. It also cools the transformer by absorbing heat. This oil has high dielectric strength. It resists electrical breakdown well.

Wärend der Operatioun baut sech Hëtzt op. The oil naturally circulates. Hot Ueleg klëmmt. Cooler Ueleg ënnerzegoen. This movement helps transfer heat away. Larger units often have cooling fins or tubes. Dës erhéijen d'Uewerfläch. More surface area means better heat dissipation to the air. Some models include radiators. Radiators boost cooling capacity further.

Protection features are built-in. The tank includes an oil conservator. This is an expansion tank. It allows the oil to expand and contract safely. A breather prevents moisture from entering the oil. Moisture harms the insulating properties. E Buchholz-Relais detektéiert intern Feeler. It provides early warning. An oil level gauge shows the oil quantity. A pressure relief valve protects against dangerous pressure build-up.

The transformer connects to power lines. It uses high-voltage bushings. These bushings safely pass conductors through the tank wall. Many units offer on-load or off-circuit tap changers. These adjust the output voltage slightly. This compensates for varying input voltage. The transformer meets standard efficiency and safety rules. It provides reliable power distribution or conversion.

Applications of Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

Oil immersed transformers handle power distribution efficiently. These strong units manage electrical energy safely. They suit many industrial and utility settings. Factories depend on them for reliable power. Mines and quarries use them in tough conditions. They work well for large buildings needing steady electricity. Substations integrate them into power grids. They step voltage up or down as needed.

These transformers come in common three-phase designs. They handle different voltage levels effectively. Lower voltages like 6kV or 10kV are standard. Higher voltages like 11kV or 25kV are also common. Power Bewäertungen variéieren wäit. Units might be 100kVA for smaller needs. Larger installations often use 200kVA or 400kVA models. The right size depends on the load.

The oil inside is key. Et killt den Transformator effektiv of. It also insulates the internal parts well. This design allows continuous operation. It handles high loads better than some dry types. The oil needs checking and replacing sometimes. Richteg Ënnerhalt garantéiert laang Liewensdauer. The strong tank protects the core and windings. These transformers are built for durability. They withstand demanding environments reliably.

They are vital for power distribution networks. Utilities rely on them daily. Industries count on them for production uptime. Their design makes them a practical choice. They deliver power where it’s needed most.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer , weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs of Oil Immersed Transformer 3 Phase 6kv 10kv 25 Kv 100 kv,400kva 200kva 11kv Oil Immersed Power Transformer

Oil Immersed Transformer FAQs: 3 Phase, 6kV-25kV, 100kVA-400kVA

People often ask about oil-immersed transformers. These are common power transformers. They handle medium voltages. Typical ratings include 6kV, 10kV an, 11kV an, 25kV an. Common power sizes are 100kVA, 200kVA, 400kVA.

Wat ass dësen Transformator? It’s a device for changing AC voltage levels. It uses electricity in three phases. De Kär an d'Wicklungen sëtzen an engem Tank gefëllt mat isoléierend Ueleg. This oil is key. The transformer steps voltage up or down for power distribution.

Why use oil? The oil does several jobs. It insulates the live parts. It stops electrical arcs. The oil also cools the transformer. Wärend der Operatioun baut sech Hëtzt op. Den Ueleg absorbéiert dës Hëtzt. It carries the heat away to the tank walls. The tank surface then releases heat to the air. This keeps the transformer working safely. Et verhënnert Iwwerhëtzung Schued.

Wéi eng Spannungen handelt et? These transformers work with medium distribution voltages. Common primary voltages are 6kV, 10kV an, 11kV an, 25kV an. The secondary voltage is usually lower, like 400V. You must match the transformer’s voltage rating to your system voltage. Déi falsch Spannung benotzen ass geféierlech. It can destroy the transformer.

Wéi wielen ech déi richteg Gréisst (kVA)? D'Gréisst (like 100kVA, 200kVA, 400kVA) means its power capacity. You need to know your total load. Add up the power needed by all equipment it will supply. Choose a transformer size bigger than your peak load. This gives a safety margin. It prevents overload. Overload causes overheating and failure. Always check the load calculations carefully.

Wéi oft ass Ënnerhalt néideg? Oil transformers need regular checks. Inspektéieren den Ueleg Niveau dacks. Sich no Leckage. Test d'Uelegqualitéit all Joer. Oil breaks down over time. Bad oil loses its insulating power. It doesn’t cool well. Dirt and water in the oil are bad. Check connections and bushings. Lauschtert fir ongewéinlech Geräischer. Follegt den Zäitplang vum Hiersteller. Gutt Ënnerhalt verhënnert Feeler. Et mécht den Transformator méi laang.

Ufro engem ZITAT

Ufro engem ZITAT