13.8kv Transformator 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformator

PRODUIT PARAMETER

Beschreiwung
Ufro engem ZITAT

Beschreiwung

Overview of 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer

13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer is an enclosed, Buedemniveau elektresch Verdeelungstransformator déi allgemeng am Ënnergrond benotzt gëtt (an) Muecht Systemer. Et fällt primär Héichspannungsstroum erof (z.B., 15kV oder 25 kV) zu enger niddereger sekundärer Spannung (z.B., 120/240V oder 480V) fir eng sécher Verdeelung a Wunnquartiere, kommerziell Gebaier, an Industrieparken. Seng robust, gespaarten Stahlkëscht mécht et sécher fir ëffentleche Beräicher.

Features of 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer

Buedem-Niveau Enclosure: A gespaarten, tamper-resistent, weatherproof Stol Cabinet datt déi intern Komponente schützt a suergt ëffentlech Sécherheet.

Ënnerierdesch Kabel Verbindungen: Entworf fir einfach Verbindung mat ënnerierdesch Primärschoul (héich Volt) an sekundär (niddereg-Volt) Kabelen iwwer Kompartimenter mat agebaute Buschungen.

Kompartimentéierung: Trennen, isoléiert Kompartimenter fir Héichspannung a Low-Volt Komponenten, d'Sécherheet beim Ënnerhalt verbesseren.

Ventilatioun: Entworf mat louvers oder aner Belëftung Systemer fir eng adäquate Hëtzt dissipation vum Transformator Kär a coils erlaben.

Ophiewe Lugs: Integréiert Lifter fir einfach a sécher Installatioun an Ersatz mat engem Kran oder Hiewel.

Tamper-proof Hardware: Sperrbar Dieren mat spezielle Bolzen fir onerlaabten Zougang ze vermeiden.

Fuséiert Schalter: Oft enthält verschmolzene Trennschalter fir Circuitschutz a sécher Isolatioun.

Pad Foundation: Installéiert op engem konkret Pad (“pad-montéiert”) e Stall ze bidden, Niveau Basis.

Specifications of 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer

Below are the essential information for our 13.8 kV Pad Placed Transformers, available in 250kVA, 300kVA, 400kVA, 500kVA, 630kVA, and 750kVA scores. These systems supply trustworthy power for areas, Geschäftsstrukturen, an industriell Siten. They link directly to below ground utility lines.

The main voltage is 13,800 volts. Usual additional voltages consist of 120/240V, 208Y/120V, 240/120V, 480Y/277V, an 480V. Typical regularity is 60Hz. Each transformer handles its ranked kVA tons continually. They operate successfully under normal problems.

Building makes use of durable steel tanks. These tanks stand up to climate and safeguard internal components. Core and coil settings up are made from high-grade electric steel and copper. This guarantees reduced losses and reliable performance. Transformers are filled with premium protecting liquid. The liquid provides cooling and insulation.

Cooling down techniques are ONAN (Ueleg Natural Air Natural) oder KNAN. This means oil flows naturally inside. Air cools the tank surface naturally outdoors. Radiators or cooling fins raise the cooling location. This layout maintains temperatures secure throughout procedure.

These transformers fulfill stringent security criteria. They consist of stress alleviation gadgets. Mistakes trigger pressure build-up. The alleviation device vents safely to prevent tank rupture. Tamper-resistant closets and safe locking secure versus unapproved accessibility. Units adhere to IEEE C57.12.22 and ANSI standards. This assures integrity and security.

Installatioun ass einfach op engem konkrete Pad. The pad gives a stable, Niveau Basis. Units include lifting hooks for positioning. Terminal plans fit different cable connections. Common devices consist of pressure assesses, fluid degree indicators, and drain valves. Surge arresters protect against voltage spikes. We offer optional attributes like reduced fluid degree alarms or remote monitoring points.

Applications of 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer

Pad-mounted transformers rated 13.8 kV and in between 250KVA and 750KVA are necessary tools. They tip down high voltage power for more secure, benotzbar Graden. These units are common in many locations. They accurately power large industrial centers. Manufacturing facilities and factory require this constant power. Hefty machinery depends on it. These transformers also sustain renewable resource projects. Solar ranches and wind setups use them. They attach generated power to the primary grid.

Next off, these transformers are important for area framework. They power whole areas. They supply electricity to real estate growths. They are additionally critical for important services. Health centers and emergency facilities call for reliable power. Institutions and colleges need them also. Public structures rely upon their constant procedure.

Zousätzlech, commercial locations benefit considerably. Shopping centers and big stores make use of these transformers. Office complexes and company parks depend upon them. They give the significant power needed for illumination, COOLING AND HEATING, and tools. Stockrooms and warehouse likewise use them. Logistics procedures require robust electrical supply.

These transformers are set up directly on concrete pads. This ground-level positioning is crucial. It makes them more secure and easier to maintain than pole-mounted systems. Utility employees access them safely. They are confined in durable, tamper-proof steel cabinets. This protects the interior elements. Oil inside cools them properly. Their style focuses on security and longevity. They take care of substantial electrical lots daily. They are developed challenging for severe exterior conditions. Weather condition does not quickly impact their performance.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs of 13.8kv Transformer 250KVA 300KVA 400KVA 500KVA 630KVA 750KVA Pad Mounted Transformer

What is a pad-mounted transformer?
Et setzt sech op engem konkrete Pad dobaussen. It steps down high voltage electricity from power lines. It delivers safer, lower voltage power to buildings or neighborhoods. You see them near businesses or homes needing lots of power.

Wéi eng Spannung handelt dësen Transformator?
Et schafft mat 13.8 kilovolt (kV an). This is a common high voltage level used by utilities. The transformer takes this high voltage. It changes it to lower voltages like 480V or 208Y/120V for use inside buildings.

Wéi eng Gréisste sinn verfügbar?
We offer several power ratings: 250 kVA, 300 kVA, 400 kVA, 500 kVA, 630 kVA, an 750 kVA. The kVA number tells you its power capacity. Pick the size matching the electrical load your project requires. Bigger loads need bigger transformers.

Where are these transformers used?
They supply power to places needing significant electricity. Examples include shopping centers, Schoulen, apartment complexes, Büro Gebaier, an industriell Siten. They feed power directly to these locations. They are also used in utility company networks.

Sinn dës Transformatoren sécher?
Jo. They are built inside a strong, locked steel tank. This tank protects people from touching live parts. It also contains insulating oil. The oil cools the transformer and prevents electrical fires. Only trained utility workers should open them.

Ufro engem ZITAT