1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformator mat ul

PRODUIT PARAMETER

Beschreiwung
Ufro engem ZITAT

Beschreiwung

Overview of 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul

1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul is an enclosed, Buedemniveau elektresch Verdeelungstransformator déi allgemeng am Ënnergrond benotzt gëtt (an) Muecht Systemer. Et fällt primär Héichspannungsstroum erof (z.B., 15kV oder 25 kV) zu enger niddereger sekundärer Spannung (z.B., 120/240V oder 480V) fir eng sécher Verdeelung a Wunnquartiere, kommerziell Gebaier, an Industrieparken. Seng robust, gespaarten Stahlkëscht mécht et sécher fir ëffentleche Beräicher.

Features of 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul

Buedem-Niveau Enclosure: A gespaarten, tamper-resistent, weatherproof Stol Cabinet datt déi intern Komponente schützt a suergt ëffentlech Sécherheet.

Ënnerierdesch Kabel Verbindungen: Entworf fir einfach Verbindung mat ënnerierdesch Primärschoul (héich Volt) an sekundär (niddereg-Volt) Kabelen iwwer Kompartimenter mat agebaute Buschungen.

Kompartimentéierung: Trennen, isoléiert Kompartimenter fir Héichspannung a Low-Volt Komponenten, d'Sécherheet beim Ënnerhalt verbesseren.

Ventilatioun: Entworf mat louvers oder aner Belëftung Systemer fir eng adäquate Hëtzt dissipation vum Transformator Kär a coils erlaben.

Ophiewe Lugs: Integréiert Lifter fir einfach a sécher Installatioun an Ersatz mat engem Kran oder Hiewel.

Tamper-proof Hardware: Sperrbar Dieren mat spezielle Bolzen fir onerlaabten Zougang ze vermeiden.

Fuséiert Schalter: Oft enthält verschmolzene Trennschalter fir Circuitschutz a sécher Isolatioun.

Pad Foundation: Installéiert op engem konkret Pad (“pad-montéiert”) e Stall ze bidden, Niveau Basis.

Specifications of 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul

This transformer handles high power needs. It comes in different sizes. The biggest is 1MVA. The smaller options are 400kVA and 500kVA. It connects to high voltage lines. The primary voltage is 13.8kV. It steps down this voltage. The secondary voltage is 277/480Y. This voltage is common for buildings. Et mécht Luuchten, Motoren, and equipment safely.

Den Transformator ass Pad-montéiert. This means it sits on a concrete slab outside. The enclosure is very strong. It is made from welded steel. Dëst schützt déi intern Deeler. Den Tank ass waasserdicht. Reen, Schnéi, and dust stay out. The design prevents tampering. Tamper-proof bolts secure the cabinet. This protects people and the equipment.

bannen, the core and coils are high quality. They use electrical steel and copper or aluminum windings. These materials ensure efficient power transfer. They also keep energy losses low. Den Transformator enthält Drockreliefgeräter. These protect against internal faults. Bushings verbannen d'Héich- an Nidderspannungskabel. They are designed for reliability.

The transformer meets UL standards. UL certification is important. It proves the unit is safe. It confirms the design meets strict North American safety rules. This gives users confidence. The unit is built for long life. Et erfuerdert wéineg Ënnerhalt. Its robust construction handles tough conditions. It provides stable power distribution reliably.

Applications of 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul

These pad-mounted transformers step down power for everyday use. They handle 13.8kV on the high-voltage side. Si liwweren 277/480 volts wye configuration on the low-voltage side. This voltage is standard in many commercial and industrial buildings in North America. These units carry UL listing. This means they meet strict safety standards.

You find these transformers serving critical power needs. The 400kVA size works well for smaller commercial buildings. Think shopping centers or office parks. Et mécht d'Beliichtung, HVAC, and office equipment. The 500kVA model suits medium-sized facilities. Examples include large retail stores or light manufacturing plants. It provides ample capacity for machinery and processes. The larger 1MVA (1000kVA) unit powers heavy loads. It supports large industrial complexes, Daten Zentren, or big hospitals. It feeds substantial machinery and essential systems.

These transformers sit outdoors on concrete pads. Their design is compact and self-contained. This saves valuable space. The locked steel enclosure protects internal components. Dëst verhënnert onerlaabten Zougang. It keeps people safe from high voltage. The enclosure is weatherproof. Et toleréiert Reen, Schnéi, Stëbs, a Sonneliicht. This ensures reliable operation in tough conditions. Pad-mounting keeps them accessible for maintenance. Technicians can easily service them when needed.

The 277/480Y secondary voltage offers flexibility. It directly powers 480V motors and heavy equipment. The 277V phase-to-neutral voltage runs lighting and outlets efficiently. This wye configuration balances loads effectively. These transformers are built for long-term reliability. They form the backbone of local power distribution networks. They deliver electricity safely to where it’s used most. They are essential for modern infrastructure.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs of 1mva 400kva 500kva 13.8kv 277/480y Pad-mounted Transformer with ul

Wat ass dësen Pad-montéierten Transformator?
Et trëfft Héichspannungsstroum erof. Et dauert 13,800 Volt aus Muecht Linnen. It outputs safer 277/480 volt power for buildings. It sits inside a locked metal box at ground level. You see these boxes near homes or businesses.

Wou gëtt dësen Transformator benotzt?
It feeds power to many buildings. It powers shopping centers, apartment complexes, Fabriken, Schoulen. It’s placed outdoors. It connects to underground power lines. It supplies the main power for a whole property.

Why is UL listing important?
UL listing means it passed strict safety tests. Independent labs checked it. It meets recognized safety standards in North America. This ensures reliable operation. Et schützt Leit a Besëtz. Utilities often require UL listed equipment.

What do 13.8kV and 277/480Y mean?
13.8kV is the input voltage. It’s the high voltage from the utility line feeding the transformer. 277/480Y is the output voltage. It provides three-phase power. The voltage between any phase wire and neutral is 277 volts. The voltage between any two phase wires is 480 volts. Déi “Y” means the windings are connected in a wye configuration.

Wéi wielen ech déi richteg Gréisst (400kVA, 500kVA, 1MVA)?
Match the size to your building’s power needs. Calculate the total load your building requires. Include all machinery, Beliichtung, HVAC. Add some extra capacity for future growth. A 400kVA unit suits medium loads. A 500kVA unit handles larger demands. A 1MVA (1000kVA) unit powers very large facilities. Your electrical engineer determines the exact size needed.

Ufro engem ZITAT

Ufro engem ZITAT