Dräi Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Oil Immersed Power Transformer is a device used to convert high voltage to lower voltage. Et ass kritesch a Kraaftsystemer, besonnesch Héichspannungs- a Verdeelungsnetzwierker. D'Haaptfunktioun vum Héichspannungstransformator ass déi stabil Operatioun vum Stroumsystem ze garantéieren wärend déi erfuerderlech Spannung fir verschidde Kraaftausrüstung ubitt.

Functional Principle of Three Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Ueleg-Immersed Power Transformer

  • Spannung Konversioun: Déi meescht Basisfunktioun vun engem Héichspannungsmuechttransformator ass d'Spannungskonversioun auszeféieren. Et reduzéiert d'Héichspannung am Stroumsystem op de Spannungsniveau, dee vum Benotzer erfuerderlech ass. Andeems Dir de Wendverhältnis vun der Primärsäit z'änneren (héich Volt Säit) an sekundär Säit (niddereg-Volt Säit) coils, Spannungserhéijung a Fall kann erreecht ginn.
  • Impedanz passende: Transformers kënnen och eng Roll bei der Impedanzmatchung spillen. Fir verschidde Lasten, hir Impedanzwäerter variéieren och. Duerch den Spannungstransformatiounseffekt vum Transformator, d'Impedanz vun der Belaaschtung kann mat der Impedanz vum Stroumversuergungssystem passen, doduerch eng stabil Stroumtransmissioun garantéiert.
  • Volt Regulatioun: Andeems Dir d'Zuel vun de Wendungen vun der Primärsäitspiral oder d'Zuel vun den Wendungen vun der sekundärer Säitspiral ännert, d'Ausgangsspannung kann ugepasst ginn. Am Muecht System, Transformatoren gi benotzt fir segmentéiert Spannungskontroll z'erreechen fir d'Elektrizitéitsbedierfnesser vu verschiddene Benotzer an Ausrüstung z'erreechen.
  • Filterfunktioun: E puer speziell Aarte vun Héichspannungs-Haapttransformatoren hunn och eng Filterfunktioun, déi harmonischen a reaktive Kraaftkomponenten an der Energieversuergung filteren an d'Qualitéit vun der Energieversuergung verbesseren.

Spezifikatioune vun Dräi Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Ueleg-Immersed Power Transformer

This three stage oil submersed power transformer manages big power jobs. It steps down high voltage electrical power for plants and substations. The transformer core sits in unique oil. This oil cools down the transformer and maintains it shielded. This style is reputable and risk-free for sturdy usage.

Its capacity ranges extensively. You can select designs rated from 3150 KVA approximately 25000 KVA. Usual sizes consist of 3000 KVA, 6300 KVA, 10000 KVA, 20000 KVA, 24000 KVA, an 25000 KVA. This adaptability fits several power needs.

The key (Input) voltage connects to high voltage lines. Typical choices are 115KV, 132KV, oder 10 KV. The additional (Ausgang) voltage offers useful power. Requirement results are 440V, 380V, oder 11 KV. These voltages match common industrial tools and distribution networks.

This transformer is built hard. It makes use of top-quality steel and copper windings. The oil storage tank is strong and sealed well. This prevents leaks. The style manages high electrical tons. It also withstands power surges and brief circuits. Normal upkeep checks are easy.

Setup needs a strong structure. Appropriate ventilation around the unit is necessary. Skilled professionals must do the electrical wiring and appointing. Adhere to the supplier’s guidelines specifically. This makes sure safe procedure and long life. The transformer meets worldwide safety standards.

It gives steady voltage outcome. This protects delicate equipment. Energy losses are kept reduced. Dëst spuert Sue mat der Zäit. The oil insulation system is very efficient. It protects against electrical failures. This transformer is a reputable power service. It works well in demanding environments.

Uwendungen vun Dräi Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Ueleg-Immersed Power Transformer

This transformer takes care of big power jobs. It transforms high voltage electrical energy to lower useful levels. It deals with three-phase systems usual in industry. The unit manages different input voltages like 115KV, 132KV, oder 10 KV. It outputs power at 440V, 380V, oder 11 KV. This adaptability is essential. Sizes vary from 3000 KVA zu 25000 KVA. This covers numerous requirements.

Atomkraaftwierk benotzt et. They step down generated voltage for the grid. Large substations depend on it. These stations feed power right into cities or factories. Heavy sector depends upon this transformer. Steel mills, chemesch Planzen, huge manufacturing facilities require this power degree. They run big electric motors, Uewen, handling lines. Mines utilize it for heavy tools and processing. Oil refineries and gas plants require this reliable power transformation.

The transformer rests submersed in oil. This oil cools down the core and windings. Good cooling prevents getting too hot. This design guarantees lengthy life under difficult problems. It takes care of continual hefty loads. The durable construction holds up against electric anxiety. This makes it trustworthy for important procedures.

Renewable resource sites need it as well. Huge solar ranches or wind parks create high voltage. This transformer steps it down for grid connection. Big hospitals, Universitéiten, or data facilities utilize it. They have major power demands. The transformer feeds their main circulation. Water treatment centers and pumping terminals use its capability. Rail networks employ it for traction power substations.

Sécherheet ass agebaut. The oil aids insulate and quench stimulates. Safety tools monitor procedure. This stops failures. The transformer is built for exterior installment. Et toleréiert Klima. Its design focuses on dependable operation for decades. This transformer is basic framework. It powers crucial large operations dependably on a daily basis.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. Wann Dir qualitativ héichwäerteg Dräi Phase wëllt 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Ueleg-Immersed Power Transformer, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs vun Dräi Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Ueleg-Immersed Power Transformer

What is the capacity range of this transformer? This unit comes in multiple power ratings. You can choose 3150 KVA, 3000 KVA, 6300 KVA, 10000 KVA, 20000 KVA, 24000 KVA, oder 25000 KVA. Pick the size that fits your electrical load. This avoids underpowering or wasting resources.

What input voltages does it accept? The primary side handles three high voltage options: 115KV, 10KV, or 132KV. This flexibility suits different grid connections. You specify the required input when ordering. It ensures compatibility with your power source.

Wéi eng Ausgangsspannungen kann et ubidden? The secondary side delivers 440V, 380V, oder 11 KV. These are common industrial and distribution voltages. It steps down high input power to usable levels. Your equipment gets the right voltage safely.

How does the cooling system function? It uses oil immersion technology. The core and windings sit in insulating oil. This oil absorbs heat during operation. Heat dissipates through radiators. This method prevents overheating and extends lifespan.

Wou ass dësen Transformator typesch installéiert? It serves heavy-duty applications. Beispiller enthalen Fabriken, Minièren, and utility substations. It powers large machinery or distributes electricity across networks. The robust design handles continuous operation. It copes with high demand environments.