300KVA 500KVA 750KVA 1000KVA Oil-Immersed Transformer 35KV 13200/240V Verdeelungstransformator Dräi Phase 380V 400V 440V 480V

PRODUIT PARAMETER

Beschreiwung
Ufro engem ZITAT

Beschreiwung

Overview of 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V

Transformator Accessoiren bezéie sech op verschidde Hëllefsausrüstung oder Materialien déi a Verbindung mat Transformatoren benotzt ginn fir hinnen ze hëllefen hir Funktiounen z'erreechen. 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V is crucial for the regular operation of transformers, well se stabil Operatioun ënner verschiddenen Ëmweltbedéngungen garantéieren an d'Effizienz an Zouverlässegkeet vun Transformatoren verbesseren. Gläichzäiteg, d'Mintenance an d'Erhaalung vun den Transformator Accessoiren sinn och wichteg Linken fir den normalen Operatioun vun den Transformatoren ze garantéieren, a regelméisseg Inspektiounen an Ersatz sinn néideg fir hir normal Operatioun ze garantéieren. Transformator Accessoiren si wesentlech Hëllefsausrüstung a Materialien fir de reguläre Betrib vun Transformatoren a si vu grousser Bedeitung fir stabil Operatioun an Effizienz.

Transformator Accessoiren enthalen haaptsächlech déi folgend Typen

Transformator Ueleg: benotzt fir Isolatioun a Killmëttel.

Transformator Ueleg Konservator: gelagert Transformator Ueleg an huet e stabile Uelegniveau behalen.

Heizkierper: Benotzt fir d'Hëtzt generéiert vum Transformator an d'Ëmgéigend Loft ze transferéieren an eng stabil Transformatortemperatur z'erhalen.

Otemschwieregkeeten: benotzt fir den internen Gasdrock vum Transformator ze regléieren an d'Verformung vum Transformator Uelegtank ze vermeiden.

Explosionsbeständeg Röhre: benotzt fir ze verhënneren datt de Gas- an Uelegfloss, deen am Fall vun internen Feeler an Transformatoren generéiert gëtt, aussprayt.

Isolatioun Hülse: benotzt fir d'Wicklungen a Leads vun Transformatoren ze schützen, verhënnert elektresche Schock a Kuerzschluss.

Thermometer: benotzt fir d'Temperatur vun den Transformatoren ze iwwerwaachen an abnormal Situatiounen direkt z'entdecken.

Gas Relais: benotzt fir den Drock an d'Temperatur vum Gas am Transformator ze iwwerwaachen a Feeler prompt z'entdecken.

Spannungs- a Stroumtransformatoren: Benotzt fir Transformatoren ze konvertéieren’ Spannungs- a Stroumsignaler an moossbar elektresch Signaler.

Blitzstopper: benotzt fir Transformatoren vu Blitz- an Iwwerspannungseffekter während der Operatioun ze schützen.

Specifications of 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V

These oil-immersed transformers handle power circulation successfully. They tip down high voltage electrical power for commercial and commercial usage. Typical power scores consist of 300KVA, 500KVA, 750KVA, and 1000KVA. This covers a variety of power demands.

The key voltage is 35KV. This connects straight to medium-voltage circulation lines. The additional voltage is 13200/240 volts. This matches specific North American distribution systems. Outcome voltages are flexible. Choices consist of 380V, 400V, 440V, an 480V. This matches different worldwide and industrial requirements.

All systems are three-phase transformers. Three-phase power is conventional for heavy equipment and big centers. The core and windings rest inside a robust steel container. The container is full of insulating oil. Dësen Ueleg killt den Transformator. It also supplies essential electrical insulation.

Natural oil blood circulation cools down smaller devices. Bigger systems commonly utilize forced air cooling. Fans blow air over radiators affixed to the tank. This improves cooling capacity. The transformer runs reliably outdoors. Placing options include pad-mounting or positioning it on a concrete plinth.

These transformers serve vital roles. They feed power to manufacturing facilities, grouss Strukturen, a Biergbau Operatiounen. They attach renewable energy resources to the grid. Defense features are crucial. Requirement installations consist of pressure alleviation gadgets and temperature determines. Buchholz relays discover interior mistakes. Oil degree indicators keep track of the protecting fluid.

Applications of 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V

These oil immersed transformers deal with major power needs. They step down high voltage electrical power to safer, benotzbar Graden. Typical dimensions are 300KVA, 500KVA, 750KVA, and 1000KVA. The 35KV primary voltage links them to regional high-voltage line. The secondary side delivers lower voltages like 240V, 380V, 400V, 440V, an 480V. This adaptability suits various devices and local standards. They are developed difficult for demanding jobs.

Manufacturing facilities rely heavily on these units. Large motors, heavy equipment, and assembly line need stable, héich-Kapazitéit Muecht. A 750KVA or 1000KVA transformer typically powers a whole production area. It makes sure makers run smoothly without voltage decreases. This avoids pricey manufacturing quits. Constant power safeguards delicate equipment as well.

Power companies use them thoroughly. They are placed in substations near communities or industrial parks. Hei, they take the 35KV incoming power. They reduce it to the distribution levels required in your area. This may be 240V for some locations or 400V/480V for others. They form the important web link between the major grid and neighborhood customers. Dependability is crucial right here.

Big structures need these transformers too. Assume mall, Gesondheetsariichtungen, workplace complicateds, or information centers. Their interior electrical systems need substantial power. A 500KVA or 750KVA system may offer the whole building. It offers the appropriate voltage for lighting, a/c Systemer, Liften, and servers. Oil cooling assists take care of the warmth from consistent high loads.

Renewable resource websites also benefit. Solar farms or wind parks generate power, often at medium voltage. This power requires conditioning and connection to the grid. These transformers deal with that interface. They tip up or down the voltage as required for grid injection. Their robust design endures exterior problems near generation points.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs of 300KVA 500KVA 750KVA 1000KVA Oil Immersed Transformer 35KV 13200/240v Distribution Transformer Three Phases 380V 400V 440V 480V

Fir wat sinn dës Transformatoren benotzt?
These oil-immersed transformers supply power for big buildings, Fabriken, an industriell Siten. They step down high voltage electricity from the power grid (35kV an) fir méi sécher, benotzbar Niveauen (like 240V, 380V, 400V, 440V, 480V). They handle large power demands reliably.

What voltages do they work with?
The primary side connects to a 35,000-volt (35kV an) supply. The secondary side gives you standard low voltages. Choose the exact output voltage you need: 240 volts, 380 volts, 400 volts, 440 volts, oder 480 volts. Si sinn fir dräi-Phase elektresch Systemer gebaut.

Where should I install one?
Install them outdoors only. They need a stable concrete pad. Leave enough open space around the transformer for safety. This space lets heat escape properly. It also gives workers room for inspections and maintenance. Keep people and objects away from the transformer.

How do they stay cool?
These transformers use special insulating oil inside the tank. The oil absorbs heat from the windings and core. As the oil heats up, it circulates naturally. The heat transfers to the external tank surface. Then the air outside cools the tank. This natural oil cooling keeps the transformer working safely.

Wat Ënnerhalt néideg ass?
Kontrolléiert den Uelegniveau regelméisseg. Sich no Leckage. Keep the tank clean. Inspektéiert Bëscher a Verbindungen. Schedule professional oil testing every few years. This checks the oil’s insulating strength. Also, have a technician inspect the internal parts periodically. Good maintenance prevents problems and extends the transformer’s life.

Ufro engem ZITAT