Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector
11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector is critical switching equipment used in electrical systems of power plants and substations. Its primary function is to guarantee the safety of high-voltage electrical appliances and equipment during maintenance work and to isolate voltage. It cannot be used to cut off, input, or disconnect load current and short-circuit current. It can only be used for certain switch operations that do not generate strong arcs—usually used in conjunction with high-voltage circuit breakers to isolate the power supply during maintenance, providing safety protection for maintenance personnel and equipment. According to the installation location and the number of insulation columns, they can be divided into indoor type, outdoor type, single-column, double-column, and three-column types. The electrical system of power plants and substations is crucial for guaranteeing the safety of maintenance personnel and equipment.
Characteristics of 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector
“Safety guarantee during maintenance of high-voltage electrical appliances and devices: This is the primary function of high-voltage isolation switches, which can ensure the safety of equipment and operators during maintenance work.
Isolation voltage: It plays the role of isolating voltage and cannot be used to cut off or connect current, nor can it be used to break short-circuit current.
Nonarc extinguishing function: It cannot be used to cut off current; that is, it does not have an arc extinguishing function.
Multiple types: According to the installation location, it can be divided by indoor and outdoor types. According to the number of insulation pillars, they can be divided into single-column, double-column, and triple-column types. Each voltage level has optional equipment.”
Specifications of 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector
This 11kV HV Exterior Disconnector provides a trusted, noticeable break point. It isolates sections of high-voltage power lines. This guarantees risk-free maintenance job downstream. The switch handles 11kV systems. It’s made for challenging exterior conditions. Rain, wind, dust, and temperature level extremes won’t influence it.
The primary shielding components use top-quality porcelain or polymer. These products use exceptional electrical resistance. They protect against existing leakages to the ground. The framework uses galvanized steel or strong light weight aluminum alloy. This gives long life and resistance to rust. The current-carrying calls are copper or copper alloy. These materials carry out electrical power effectively. They lessen power loss during typical operation.
The button blade relocates clearly. You see the open or shut position quickly. This visible gap is important for safety. Operators recognize the circuit is isolated. The switch holds up against high fault currents. It endures short-circuit problems without damages. The layout ensures stability under high electro-magnetic forces.
Operation is commonly manual. An operator utilizes a shielded pole from ground degree. The operating mechanism needs reasonable pressure. It usually calls for under 200 Newtons. Some versions use motorized procedure. This allows remote control from a range. Both types ensure favorable switching activity. The switch locks safely in the open placement. Padlocks offer physical safety and security. Workers recognize the circuit remains isolated.
The button base places securely on a structure. It uses standard holes for very easy installment. Clearances satisfy stringent security guidelines. The range between phases avoids flashovers. The range to planet is also secure. These clearances stop harmful arcing. The disconnector handles continual ranked currents. Typical scores are 630A, 800A, or 1250A. It performs accurately for several years.
Applications of 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector
11kV HV outdoor disconnectors are vital safety and security devices in electrical power networks. They deal with high voltages safely outdoors. Their major work is clear seclusion. Workers require to physically separate electrical circuits. This ensures security during upkeep or repairs. People call them separating buttons or blade switches over too. You see them commonly in substations and along power lines.
These switches produce a visible air gap. This void validates the circuit is really dead. Seeing the gap is essential for employee safety and security. It avoids unintended call with real-time components. Professionals can after that securely work with transformers or other devices downstream. They likewise isolate sections of expenses lines. This allows secure repair work on details line sections. The remainder of the network keeps running generally.
One more vital use is separating transformer feeders. Workers cut power to transformers securely. This occurs before any kind of maintenance or checks. Disconnectors are also used for busbar area isolation. Busbars carry power within substations. Separating components aids manage power flow. It allows maintenance without closing down the entire substation.
In some cases these switches handle load currents. They switch over circuits under light tons problems. However they are not circuit breakers. They can not quit big mistake currents. They function alongside breaker. The breaker interrupts hefty faults. The disconnector after that supplies safe isolation after the fault is removed. Correct procedure sequence is essential. The circuit breaker should open up first. Then the disconnector can safely open.
Resilience is essential for these outside switches. They encounter severe weather condition regularly. Rainfall, wind, dirt, and temperature level extremes test them. Robust building and construction stops corrosion and makes sure reliable operation. Normal examination and maintenance are needed. This keeps them operating correctly for years. They are essential for safe and adaptable power system operation.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 11kV HV Outdoor Disconnector/disconnecting Switch/ Isolating Switch Knife Switch Disconnector
What is an 11kV HV Outdoor Disconnector?
It’s a switch for high-voltage power lines. It physically cuts the electrical connection. This happens at 11,000 volts. It ensures a circuit section is totally dead before work starts. It’s a vital safety device.
Why is it installed outdoors?
These disconnectors handle high voltage. They need space for safety. Outdoor air provides insulation between live parts. Weatherproof construction protects against rain, dust, and wind. Indoor installation isn’t safe for this voltage level.
What are the main features?
Look for visible contact separation. You see the gap confirming isolation. Strong insulation withstands high voltage outdoors. Robust construction handles weather and mechanical stress. Simple operation is manual, often with an insulated pole. Clear open/close positions are essential.
How is it different from a circuit breaker?
Disconnectors only open circuits with no current flowing. They break load current. Circuit breakers interrupt heavy currents, like during faults. Disconnectors provide a visible safety gap. Circuit breakers protect the system from damage.
What safety rules apply?
Never open it under load. This causes dangerous arcing. Always open it only after the circuit breaker trips upstream. Lock it in the open position before starting work. Ground the isolated section for extra safety. Follow strict electrical safety procedures every time.
REQUEST A QUOTE
RELATED PRODUCTS
 
GN19-12 Indoor High Voltage Isolating Switch Load Break Switch 12kv Load Isolator Switch Disconnector
 
s supply GW4-40.5 400A 630A 1000A hv disconnector
 
Ceramic single-pole three-phase AC high-voltage disconnector China Manufacturer
 
630a outdoor high voltage disconnector 10kv 12kv China Manufacturer
 
10KV Three phase Three-phase AC Column Upper Switch China Manufacturer
 