Overview of GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch
GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch is critical switching equipment used in electrical systems of power plants and substations. Its primary function is to guarantee the safety of high-voltage electrical appliances and equipment during maintenance work and to isolate voltage. It cannot be used to cut off, input, or disconnect load current and short-circuit current. It can only be used for certain switch operations that do not generate strong arcs—usually used in conjunction with high-voltage circuit breakers to isolate the power supply during maintenance, providing safety protection for maintenance personnel and equipment. According to the installation location and the number of insulation columns, they can be divided into indoor type, outdoor type, single-column, double-column, and three-column types. The electrical system of power plants and substations is crucial for guaranteeing the safety of maintenance personnel and equipment.
Characteristics of GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch
“Safety guarantee during maintenance of high-voltage electrical appliances and devices: This is the primary function of high-voltage isolation switches, which can ensure the safety of equipment and operators during maintenance work.
Isolation voltage: It plays the role of isolating voltage and cannot be used to cut off or connect current, nor can it be used to break short-circuit current.
Nonarc extinguishing function: It cannot be used to cut off current; that is, it does not have an arc extinguishing function.
Multiple types: According to the installation location, it can be divided by indoor and outdoor types. According to the number of insulation pillars, they can be divided into single-column, double-column, and triple-column types. Each voltage level has optional equipment.”
Specifications of GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch
Here’s the GW4 Outside Disconnector Switch over specification. This button handles 33kV, 35kV, or 40.5 kV systems. It takes care of currents approximately 630 Amps. It’s constructed for outside usage. The layout is strong. It stands up to challenging weather condition.
The major work is isolation. It supplies a clear break in the circuit. Operators see the open void. This validates security throughout maintenance. The get in touches with are visible. You know the button setting. The relocating call turns. It opens up or closes the circuit.
The base frame is robust steel. It makes certain security. The insulation uses state-of-the-art porcelain or polymer. Porcelain uses proven performance. Polymer is lighter and immune to effect. Both kinds meet the voltage requires. Creepage range suffices. It manages air pollution degrees typical outdoors.
The switch operates manually. A straightforward turning deal with controls it. The procedure is smooth. The system is reliable. Mechanical interlocks are feasible. These avoid dangerous procedure sequences. Padlocking factors are basic. You lock the button open or closed. This avoids unexpected procedure.
Security is vital. The open void meets strict criteria. It stands up to the needed voltage without flashover. The earthing alternative is readily available. You can add earthing blades. This premises the isolated circuit section. Bonus security for employees.
The button endures rough conditions. It functions penalty in temperatures from -40 ° C to +40 ° C. It handles high moisture. It resists salt haze. It copes with wind and ice. The materials resist corrosion. Galvanized steel or stainless steel parts prevail.
Setup is simple. It fits conventional substation frameworks. Maintenance needs are reduced. The layout is easy and proven. It’s a reliable choice for clear circuit seclusion outdoors. It fulfills basic electric ratings for dependability.
Applications of GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch
The GW4 Outside Disconnector Switch over manages high voltage. It operates at 33kV, 35kV, and 40.5 kV levels. Its current score is 630A. This button is crucial for safely isolating electrical equipment. It makes certain power sections are entirely de-energized. This enables safe upkeep job. Employees require this security. High voltage is dangerous.
You see this disconnector in many areas. Electric substations use it typically. It regulates areas of the power grid. Operators require to isolate transformers. They need to separate breaker and busbars. Regular checks need seclusion. Repair work call for isolation. This switch makes it risk-free.
Industrial plants depend on it also. Factories have large motors. They have heaters and intricate machinery. These require power isolation for solution. The GW4 offers a noticeable break factor. Service technicians see the circuit is open. This prevents mishaps. It protects people and equipment.
Renewable energy websites utilize this disconnector. Solar farms have several panels. Wind farms have huge turbines. They link to the primary grid. Upkeep occurs frequently. Safety and security disconnection is important. The GW4 handles the voltage. It manages the present. It functions dependably outdoors.
Railway electrification systems need trusted disconnectors. Trains make use of high voltage power. Areas of track require isolation. Upkeep teams require security. The GW4 is built difficult. It endures climate. It offers clear isolation points.
Its layout is simple and durable. It runs by hand. This is reputable. No exterior power is needed. It includes visible get in touches with. You see the open space. This validates isolation. It has solid insulation. It withstands high voltage stress and anxiety. It deals with contamination and salt. It handles wide temperature modifications. This makes it resilient.
The switch makes sure compliance with safety and security regulations. Electric systems have stringent requirements. The GW4 satisfies these needs. It supplies necessary seclusion. It secures workers everywhere high voltage is present. Its performance is verified. It is a crucial element for power control.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of GW4 Outdoor 33kV, 35kV, 40.5kV, 630A Disconnector Switch
What is the GW4 Outdoor Disconnector Switch?
It’s a heavy-duty switch. It physically isolates parts of a high-voltage power line. Workers use it for safety during maintenance. It ensures no electricity flows where they are working. It’s mounted outdoors on poles or structures.
Where is this switch typically used?
You find it on overhead power lines. These lines carry electricity at 33kV, 35kV, or 40.5kV. It’s common in substations feeding towns or factories. It’s also used on long-distance power distribution networks. Its job is creating a safe isolation point.
Why is visible isolation important?
Seeing the physical gap matters. It confirms the circuit is truly dead. Workers need this absolute safety guarantee. Relying only on other breakers isn’t safe enough. A visible break prevents deadly accidents. It’s a critical safety step before work starts.
What voltage and current can it handle?
This switch is built for tough jobs. It reliably works with voltages up to 40.5kV. It can carry a continuous current of 630 Amperes. It handles normal load currents safely. It withstands short-circuit currents briefly. Its design meets strict standards for these ratings.
Does it need much maintenance?
Its design is simple and robust. It requires minimal routine maintenance. Inspections check for corrosion or damage. Moving parts need occasional lubrication. Harsh environments might need more frequent checks. Proper installation ensures long life and reliability.
REQUEST A QUOTE
RELATED PRODUCTS
 
33kV Outdoor HV Load Break Switch Isolator Disconnector HV LBS SF6 Transmission Substation
 
Low Voltage Disconnector RPS-4 400A Left Hand Drive Isolating Knife Switch 3P Fuse Disconnect Knife Switch
 
High Voltage Load Break Switches PB3-10KV Safely Industrial Use Disconnector Switch 10kV 1000A From Chinese
 
10KV Three phase Three-phase AC Column Upper Switch China Manufacturer
 
Premium GN19-12 Indoor High-Voltage Isolation Disconnector For MV Switchgear
 