Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers
Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers is critical switching equipment used in electrical systems of power plants and substations. Its primary function is to guarantee the safety of high-voltage electrical appliances and equipment during maintenance work and to isolate voltage. It cannot be used to cut off, input, or disconnect load current and short-circuit current. It can only be used for certain switch operations that do not generate strong arcs—usually used in conjunction with high-voltage circuit breakers to isolate the power supply during maintenance, providing safety protection for maintenance personnel and equipment. According to the installation location and the number of insulation columns, they can be divided into indoor type, outdoor type, single-column, double-column, and three-column types. The electrical system of power plants and substations is crucial for guaranteeing the safety of maintenance personnel and equipment.
Characteristics of Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers
“Safety guarantee during maintenance of high-voltage electrical appliances and devices: This is the primary function of high-voltage isolation switches, which can ensure the safety of equipment and operators during maintenance work.
Isolation voltage: It plays the role of isolating voltage and cannot be used to cut off or connect current, nor can it be used to break short-circuit current.
Nonarc extinguishing function: It cannot be used to cut off current; that is, it does not have an arc extinguishing function.
Multiple types: According to the installation location, it can be divided by indoor and outdoor types. According to the number of insulation pillars, they can be divided into single-column, double-column, and triple-column types. Each voltage level has optional equipment.”
Specifications of Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers
Hot ing outside HV load break switches manage 12kV and 24kV systems. They work as disconnect switches too. These are constructed tough for outdoor usage. Rainfall, wind, dust won’t stop them. The vacuum circuit breakers inside break mistakes cleanly. They cut off 20kA short circuits securely. This high splitting capacity safeguards your tools.
Factory direct sales mean much better costs for you. You miss middlemen prices. Quality stays high because we control production. Every device passes stringent examinations before delivery. We check insulation toughness. We verify switching speeds. We validate call resistance levels.
Setup is straightforward. Mount them on posts or frameworks. They fit common configurations. Upkeep demands are low. The vacuum interrupters ins 2015 without solution. Visual examinations are usually sufficient.
These buttons suit several areas. Utilize them in power circulation networks. They shield transformers on posts. They separate lines for risk-free repair work. Substations utilize them for feeder control. Industries rely on them for plant power. Renewable energy farms require them as well.
Safety and security features are important. The buttons have noticeable break points. You see the open void for grounding. Locking options avoid accidental closure. Operating deals with are convenient.
Materials withstand deterioration. Stainless-steel and special finishes are used. Seals keep wetness out of the device. Relocating components function efficiently in chilly or heat.
Select between manual or mechanized operation. Hand-operated types use easy rotating handles. Motorized variations allow remote. Both alternatives make sure trusted switching.
Voltage scores cover usual demands. 12kV designs take care of most circulation lines. 24kV variations suit greater voltage systems. Damaging ability fulfills grid demands. 20kA ranking deals with hard faults.
Vacuum technology makes them reliable. Arcs obtain snuffed out fast inside the chamber. Contacts remain clean for consistent performance. Disturbance happens in nanoseconds.
Order straight from our factory. Customized configurations are possible. Obtain precisely what your task requires.
Applications of Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers
Power companies need dependable equipment for outdoor high-voltage line. These vacuum breaker and lots buttons manage that task well. They operate at 12kV and 24kV voltages typical in circulation networks. Their 20kA damaging ability indicates they safely stop large mistake currents. This secures costly transformers and various other devices down the line.
Operators utilize these switches for routine upkeep. They separate sections of line safely. The visible seclusion gap verifies the circuit is dead. Workers can then service transformers or lines without threat. This is important for keeping the power streaming dependably.
Industrial sites rely on these buttons also. Manufacturing facilities have intricate power demands. These breakers secure essential machinery from electrical mistakes. They separate certain plant areas for fixings. The robust outside layout endures severe manufacturing facility atmospheres. Rain, dirt, and temperature modifications don’t stop them.
Renewable energy jobs make use of these buttons. Solar farms and wind installments link to the primary grid. These breakers handle the connection points. They safely separate the sustainable resource when needed. They take care of the switching currents reliably. Their vacuum cleaner disturbance technology guarantees lengthy life with minimal upkeep.
Substations are one more essential location. These switches control power circulation in between different circuits. They supply clear isolation points for safety. Professionals value the uncomplicated operation. The high splitting capacity uses peace of mind throughout mistakes. Factory straight supply frequently indicates much better worth and quicker distribution.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of Hot ing 12kV 24kV Outdoor HV Load Switch Disconnect Switch 20ka Breaking Capacity Factory Direct Vacuum Circuit Breakers
Here are 5 common questions about our Hot ing 12kV/24kV Outdoor HV Load Switch Disconnect Switch with 20kA breaking capacity and factory direct vacuum circuit breakers:
What exactly is this product?
This is a heavy-duty outdoor switch. It combines two functions. It safely disconnects high voltage circuits like a load switch. It also protects circuits by interrupting fault currents like a vacuum circuit breaker. It handles 12,000 volts or 24,000 volts systems. It’s built for tough outdoor conditions.
What are its main features?
Key features include the 20kA fault current breaking ability. It uses reliable vacuum interruption technology inside the breaker. The load switch part provides clear visible isolation. The whole unit is designed for outdoor use. It resists weather, dust, and corrosion. Installation is straightforward.
What does “20kA Breaking Capacity” mean?
Breaking capacity is crucial. It tells you how much fault current the breaker can safely stop. 20kA means it interrupts 20,000 Amperes safely during a short circuit. This high rating ensures protection for your equipment and personnel. It prevents damage from electrical faults.
Why does “Factory Direct” matter?
Buying factory direct gives you important advantages. You get the best possible price. There are no extra middleman costs. You deal directly with the manufacturer. This means better support and clear communication. You know the product source is reliable. Quality control is consistent.
Can one unit handle both 12kV and 24kV systems?
Yes. This specific model is rated for both voltage levels. It operates safely on either 12,000 volt or 24,000 volt networks. You don’t need separate devices for these common distribution voltages. It offers flexibility for different project needs. Installation crews find this versatility useful.
REQUEST A QUOTE
RELATED PRODUCTS
33KV 630Amp Outdoor Switch Disconnector / Disconnect Switch / Isolator Switch
GW4 Outdoor High Voltage 12kV 35kV Three Pole Electrical Operation Type Disconnector Isolator Switch
Reliable NALF 12KV Indoor Load Break Switch FN18-12 LBS, High Voltage Isolator Disconnector For Power Distribution Systems
Supply high-voltage disconnector 12KV 400A pole switch China Manufacturer
72.5KV 110KV 126KV 132KV 145KV GW4 Outdoor High Voltage Disconnector / Disconnect Switch


