Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250
HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250 is critical switching equipment used in electrical systems of power plants and substations. Its primary function is to guarantee the safety of high-voltage electrical appliances and equipment during maintenance work and to isolate voltage. It cannot be used to cut off, input, or disconnect load current and short-circuit current. It can only be used for certain switch operations that do not generate strong arcs—usually used in conjunction with high-voltage circuit breakers to isolate the power supply during maintenance, providing safety protection for maintenance personnel and equipment. According to the installation location and the number of insulation columns, they can be divided into indoor type, outdoor type, single-column, double-column, and three-column types. The electrical system of power plants and substations is crucial for guaranteeing the safety of maintenance personnel and equipment.
Characteristics of HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250
“Safety guarantee during maintenance of high-voltage electrical appliances and devices: This is the primary function of high-voltage isolation switches, which can ensure the safety of equipment and operators during maintenance work.
Isolation voltage: It plays the role of isolating voltage and cannot be used to cut off or connect current, nor can it be used to break short-circuit current.
Nonarc extinguishing function: It cannot be used to cut off current; that is, it does not have an arc extinguishing function.
Multiple types: According to the installation location, it can be divided by indoor and outdoor types. According to the number of insulation pillars, they can be divided into single-column, double-column, and triple-column types. Each voltage level has optional equipment.”
Specifications of HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250
This HV Lots Break Change Isolator Disconnector supplies reliable power seclusion. It is created for 33kV systems. This switch operates outdoors. It manages high voltage applications safely. The three-phase layout is standard for power distribution networks. It handles currents approximately 1250 Amps. This capacity matches numerous industrial and utility needs.
Procedure is simple and very easy. Employees can operate it by hand. This hands-on procedure is straightforward. It calls for minimal training. Clear visual indicators validate the button position. You see quickly if it is open or closed. This aesthetic confirmation is crucial for safety. It avoids blunders throughout upkeep or fixings. The system ensures smooth changing action. It feels solid and reliable each time.
Building and construction concentrates on resilience and safety. The base utilizes solid galvanized steel. Stainless-steel components stand up to rust. Silicone rubber insulators supply outstanding weather security. Rainfall, dust, and UV light cause minimal damages. This robust build guarantees lengthy life span. It endures harsh exterior environments dependably.
Safety is a primary function. The button gives a visible seclusion void. You see the physical break in the circuit. This space validates electrical isolation. It shields workers from real-time components. Safe and secure mechanical interlocks protect against unintended operation. The button locks firmly in the open or shut setting. It can not close suddenly. This safety is vital for secure working problems. Trusted basing factors are included. Correct grounding safeguards employees and tools.
The design stresses low maintenance. Couple of moving components reduce wear. Secured bearings shield internal mechanisms. Regular evaluations are normally adequate. This conserves time and functional costs. The button guarantees dependable circuit seclusion. It is a useful remedy for taking care of high voltage power securely.
Applications of HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250
This 33kV outdoor isolator switch takes care of high voltage securely. It is a three-phase disconnector ranked for 1250 amps. Its main work is to visibly separate components of an electric circuit. This splitting up makes sure security throughout upkeep or repairs. Employees can see the open space. They recognize the circuit is de-energized. This avoids crashes.
The switch is built for difficult exterior conditions. It withstands weather condition like rainfall, wind, and dust. This makes it dependable for many different power configurations. You discover it frequently in electric substations. Right here it isolates transformers or circuit breakers. Technicians need risk-free access for checks. The isolator offers that important break factor.
Industrial plants use this switch as well. Big factories have complicated power circulation. The isolator enables secure closure of certain tools areas. Maintenance crews repair motors or various other machinery safely. Power stays on elsewhere in the manufacturing facility. Production does not need a full stop.
Renewable resource sites take advantage of this isolator. Solar ranches and wind parks attach to the grid. This switch isolates sections for repairing or upgrades. Technicians can work with inverters or transformers securely. The remainder of the power generation continues.
Its procedure is basic and easy. Operators use a manual deal with or a protected pole. The action is clear and positive. You really feel the button open or close safely. This simpleness is essential for safety. Facility mechanisms can stop working or puzzle. This layout lessens that threat. Training is simple. Employees find out to use it swiftly and appropriately.
The 1250 amp score deals with substantial power tons. It fits numerous medium voltage distribution networks. The durable building makes sure lengthy life span. It requires minimal maintenance itself. Evaluations are typically visual. Operators examine the get in touches with and device regularly. This conserves money and time. Integrity is high.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of HV Load Break Switch Isolator Disconnector Simple and Easy Operation33kv Outdoor Isolator Switch 3 Phase Isolating Switch 1250
This 33kV Outdoor Isolator Switch is built for simple, reliable operation. It handles 1250A loads safely. Here are answers to common questions:
Is this switch easy to operate?
Yes, operation is very simple. The mechanism is straightforward. Manual operation uses a standard handle. Operators find it easy to open and close. The design minimizes effort. Clear visual position indicators show ON/OFF status. Anyone trained can use it safely.
Is it safe for outdoor use?
Absolutely. The switch is made for tough outdoor conditions. Its housing resists weather, dust, and pollution. Special insulation keeps things safe even when wet. Extra distance (creepage) prevents electrical tracking on surfaces. Materials withstand UV light and temperature changes. It performs reliably year after year outside.
How does it handle electrical arcs?
The switch controls arcs safely. Special contacts and chambers quickly extinguish arcs when switching under load. This protects the equipment. It stops dangerous arcs from forming or spreading. The design ensures safe breaking every time. Operators stay protected.
What installation space is needed?
You need enough clear space around the switch. This allows safe operation and maintenance. The exact space depends on your setup. Follow the manufacturer’s drawings carefully. Ensure proper clearances to other equipment and structures. Correct spacing prevents electrical flashovers. It also gives technicians safe access.
Does it need much maintenance?
Routine checks are essential. Inspect contacts and moving parts periodically. Look for wear or damage. Lubricate points as the manual specifies. Keep insulators clean. Check tightness of electrical connections. Overall, maintenance demands are low. The robust design ensures long service life with basic care.
REQUEST A QUOTE
RELATED PRODUCTS
 
China Factory 110kV 126kv Outdoor MV&HV Products Disconnect Switch Disconnector Load Break Switch
 
Outdoor GW4 Series High Voltage Disconnector / Isolator Switch 72.5KV 110KV 126KV 145KV 2500A
 
35KV Outdoor Line High Voltage Disconnector GW9 Silicone Rubber Type High Voltage Disconnector Power Station Type
 
10KV Three phase Three-phase AC Column Upper Switch China Manufacturer
 
CE Certified 1P/2P/3P/4P Outdoor Isolating Switch Disconnector Waterproof IP65 for Industrial Use
 


