Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse
Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse is critical switching equipment used in electrical systems of power plants and substations. Its primary function is to guarantee the safety of high-voltage electrical appliances and equipment during maintenance work and to isolate voltage. It cannot be used to cut off, input, or disconnect load current and short-circuit current. It can only be used for certain switch operations that do not generate strong arcs—usually used in conjunction with high-voltage circuit breakers to isolate the power supply during maintenance, providing safety protection for maintenance personnel and equipment. According to the installation location and the number of insulation columns, they can be divided into indoor type, outdoor type, single-column, double-column, and three-column types. The electrical system of power plants and substations is crucial for guaranteeing the safety of maintenance personnel and equipment.
Characteristics of Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse
“Safety guarantee during maintenance of high-voltage electrical appliances and devices: This is the primary function of high-voltage isolation switches, which can ensure the safety of equipment and operators during maintenance work.
Isolation voltage: It plays the role of isolating voltage and cannot be used to cut off or connect current, nor can it be used to break short-circuit current.
Nonarc extinguishing function: It cannot be used to cut off current; that is, it does not have an arc extinguishing function.
Multiple types: According to the installation location, it can be divided by indoor and outdoor types. According to the number of insulation pillars, they can be divided into single-column, double-column, and triple-column types. Each voltage level has optional equipment.”
Specifications of Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse
These disconnectors regulate battery power circulation. They combine switching and fusing. They shield circuits. They separate batteries safely. You pick the pole count: 1P, 2P, or 3P. This matches your battery configuration. They deal with high currents: 250A, 400A, or 630A. Pick the rating matching your system’s lots. Voltage capability is solid. They collaborate with air conditioner systems up to 690V. They manage DC battery systems up to 440V. This covers lots of industrial and renewable resource needs.
The fuse component is integrated. It protects against unsafe overloads. It stops too much current quick. The button component isolates the battery. This is important for maintenance. It guarantees employee security. Operators can open up the switch manually. This reduces power entirely. It develops a noticeable break. You see the circuit is open. This validates isolation. The layout is durable. It deals with high electric stress and anxiety. Building utilizes resilient materials. This ensures long service life. Trusted operation is vital.
These devices fit demanding settings. Use them in battery energy storage space systems. They fit solar energy setups. They operate in UPS back-up systems. They shield industrial DC circuits. The fuse-switch combo is effective. It conserves panel space. Installment is uncomplicated. Clear markings aid proper wiring. Safety and security requirements are satisfied. This provides peace of mind. Normal examination is recommended. Examine get in touches with and fuse problem. Proper procedure depends upon this.
Applications of Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse
Whole battery disconnectors, like the 1P, 2P, and 3P designs rated 250A, 400A, and 630A, are vital safety and security gadgets. They take care of both air conditioner (approximately 690V) and DC (approximately 440V) systems. These fuse switch disconnectors offer numerous essential objectives in battery configurations.
Their primary work is providing a safe, visible break point. Operators can literally open the button. This action isolates the battery bank completely. Seclusion is crucial for secure upkeep or repair. Specialists can service linked equipment without real-time voltage risks. The visible void validates the circuit is dead.
These disconnectors likewise serve as emergency closure buttons. A trouble arises in the system. Worker can quickly reduce power at the source. This rapid disconnection avoids additional damages. It boosts general system safety.
The integrated fuse component provides essential protection. It defends against unsafe overcurrents. This consists of short circuits. A brief circuit happens. The fuse impacts fast. This action quits extreme current flow. It shields expensive battery cells. It safeguards downstream circuitry and tools from fire or crisis. The disconnector body safely has the fuse procedure.
These units prevail in large energy storage space systems (ESS). They take care of battery strings in solar ranches. They manage battery strings in wind installations. They take care of backup power financial institutions. They handle the high currents involved. They provide the essential seclusion and protection. They are likewise utilized in industrial DC power systems. Electric vehicle charging infrastructure utilizes them. Any type of application utilizing big battery financial institutions needs reliable disconnection and protection.
Choosing the appropriate model depends upon system voltage. It relies on optimum operating current (250A, 400A, 630A). It depends on the number of poles required (1P, 2P, 3P). Proper selection makes certain trusted operation. It guarantees safety throughout the battery system’s life. These disconnectors are fundamental for control. They are basic for safety in high-power DC and air conditioner battery circuits.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of Whole Battery Disconnector 1P 2P 3P 250A 400A 630A Fuse Switch Disconnectors AC690V DC440V Battery Fuse
Whole Battery Disconnector FAQs: 1P, 2P, 3P, 250A-630A, AC690V/DC440V
What is this battery disconnector?
This unit is a combined fuse and switch. It safely isolates your battery bank from the rest of the system. It handles high currents (250A, 400A, or 630A) and high voltages (AC up to 690V, DC up to 440V). It protects circuits and allows safe maintenance.
Why use a fused disconnector instead of a plain switch?
Safety is the main reason. A plain switch only breaks the circuit. This device has a built-in fuse. The fuse blows instantly if there’s a massive overload or short circuit. This stops dangerous sparks and cuts power fast. It protects your expensive batteries and equipment from damage.
What do the 1P, 2P, and 3P options mean?
These tell you how many separate poles the disconnector has. Think of one pole as controlling one battery circuit. Use 1P for disconnecting a single battery string. Use 2P for two separate strings. Use 3P for three separate strings. Each pole has its own fuse and switch mechanism.
What voltage levels can it handle?
This disconnector is built tough for demanding systems. It works with both Alternating Current (AC) and Direct Current (DC). The maximum AC voltage rating is 690 volts. The maximum DC voltage rating is 440 volts. This covers most large battery storage and industrial power applications.
Can I install this myself?
Working with high-voltage, high-current battery systems is dangerous. Installation requires specific skills and knowledge. Only qualified electricians or technicians should install this disconnector. They understand the electrical codes and safety procedures. They ensure the connections are correct and secure. Improper installation risks fire, equipment failure, or serious injury. Get professional help.
REQUEST A QUOTE
RELATED PRODUCTS
630a outdoor high voltage disconnector 10kv 12kv China Manufacturer
33KV 630Amp Outdoor Switch Disconnector / Disconnect Switch / Isolator Switch
Mady DC Disconnector Switch 1000V 4P 32A for Solar PV System DC Isolator Switch
China Factory 110kV 126kv Outdoor MV&HV Products Disconnect Switch Disconnector Load Break Switch