Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output
1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output is used to monitor the temperature during industrial production processes, which are crucial for equipment operation, product quality, and production safety. There are various types, such as thermal resistance thermometers, thermocouple thermometers, infrared thermometers, optical thermometers, etc., each with its advantages, disadvantages, and applicable ranges, which need to be selected according to specific usage environments and measurement requirements. Regularly inspect and calibrate to ensure accuracy and reliability, providing reliable temperature measurement data for industrial production. Choosing and using industrial thermometers correctly can ensure the smooth progress of the industrial output.
Characteristics of 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output
High precision measurement: It usually has a high-precision temperature measurement function, which can accurately measure and display temperature values. This is thanks to the use of precision temperature sensors and measurement circuits.
Wide temperature range: able to adapt to a wide range of temperatures and measure and control industrial processes from extremely low to high temperatures. Different models of temperature controllers may have different temperature ranges, and users can choose the appropriate model according to their specific needs.
Multiple control modes: Usually supports multiple control modes, such as proportional control, PID control, fuzzy control, etc. These control modes can be selected and adjusted according to actual needs to achieve precise temperature control and stability.
Multiple output modes: With multiple output modes for communication and control with other devices or systems. Common output methods include analog output (such as current or voltage signals), digital output (such as RS485 communication interface), and relay output.
Large screen display: Provided with a large screen display, it can clearly display the current temperature, set temperature, and other related information. This allows users to visually monitor temperature changes and device status, making it convenient to operate and adjust parameters.
Strong anti-interference ability: There are often various sources of interference in industrial environments, such as electromagnetic interference, vibration, and temperature fluctuations. Industrial thermometers usually have strong anti-interference ability, and anti-interference design and filtering algorithms are adopted to reduce the impact of interference on temperature measurement and control.
Programmable function: With programmable function, users can customize settings and operations according to their needs. Users can set temperature curves, time control, and alarm functions through the programming interface to meet the needs of complex industrial processes.
Security protection function: usually has multiple security protection functions to ensure the safety of equipment and processes. For example, it can have functions such as over temperature protection, power outage memory, and fault alarm to prevent timely measures from being taken in case of temperature exceeding the safe range or equipment failure.
Easy installation: Industrial thermometers can be installed in various ways, such as axial, radial, and universal, making it convenient for users to use.
Good durability and reliability: Industrial thermometers are usually made of high-quality materials and processes, which have good durability and reliability and can work stably for a long time.”
Specification of 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output
This commercial thermometer procedures temperature level accurately. It makes use of a gas-filled system. The gas broadens or acquires with temperature level modifications. This motion drives the dial indication. You see the temperature clearly. It’s developed for challenging manufacturing facility settings. It deals with resonance well. It handles dirt as well. It functions accurately popular areas.
The sensor links to the dial via a long capillary tube. This tube can be meters long. You can place the sensor where needed. The dial sits somewhere else. This is useful in limited areas. Or where seeing the dial is hard. The tube flexes quickly. You can path it around challenges. Installment is less complex.
Its essential attribute is the electric contacts. These are inductive switch get in touches with. They are completely secured. No physical parts touch within. This makes them spark-free. Safe for unsafe areas. They last much longer. They do not break swiftly. The calls give an easy signal. They open up or shut a circuit. You get a fundamental on/off signal. Use this signal to cause alarms. Or manage other tools. Or send out data to a PLC system. It integrates quickly.
Precision is essential. This thermostat is precise within 1% of its complete range. You get dependable analyses. The dial face is big. Numbers are easy to review. It’s developed from strong products. Typically stainless-steel. It stands up to corrosion. It manages high stress. Temperature level arrays vary. You choose the ideal model. Usual ranges include -20 to +120 ° C or 0 to 400 ° C. It keeps track of liquids well. It examines gases too. It operates in pipes and tanks. It’s a solid, useful tool. It offers you a clear temperature analysis. Plus it provides a trusted electrical signal.
Applications of 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output
This thermometer gauges temperature level properly in tough industrial setups. It uses a gas-filled capillary system. The gas broadens or gets with temperature level adjustments. This activity drives the dial reminder. It likewise moves special inductive electric contacts inside. These calls are not mechanical switches. They work through electromagnetic fields. This makes them extremely trusted. They do not wear quickly from switching. They do not spark either. This is safer near flammable materials.
The device uses a 1% accuracy rating. This accuracy is essential for vital processes. The capillary tube enables remote sensing. You can mount the dial far from the hot point. This protects the gauge. Tubes can be a number of meters long. This includes flexibility for installation.
The main work is offering button call signals. You set high or reduced temperature restrictions on the dial. When the temperature strikes a collection point, the inductive call sets off. It sends an electrical signal promptly. This signal can most likely to a control area light, an alarm bell, or a PLC. The PLC can after that start or stop devices automatically. It allows fundamental on/off control based upon temperature.
Utilize it where you require straightforward, trusted temperature level alarm systems or control activities. Screen birthing temperatures on huge motors. Protect against overheating damage. Watch fluid temperatures in containers or pipes. Signal if it gets also hot or also chilly. Control home heating or cooling down systems in manufacturing facilities. Make sure food processing stays within safe temperature bands. Guard against freezing in cooling and heating systems. Protect central heating boilers or activators from exceeding risk-free limits. Its rugged construct handles resonance, dust, and wide temperature level ranges. The gas-actuated system is robust. The inductive get in touches with guarantee lengthy life and safe operation. This combination supplies reliable button signals for crucial temperature level monitoring.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 1% Capillary Industrial Inductive Electric Contact Thermometer Gas-actuated Thermometer with Switch Contacts Signal Output
This thermometer measures temperature remotely. It uses a gas-filled system. The gas expands or contracts with temperature changes. This movement drives the dial pointer. Electrical contacts are built-in. They trigger signals at set points. The capillary tube allows installation away from the sensing point. It’s for industrial settings.
What exactly does this thermometer measure?
It measures temperature. The sensing bulb goes where you need the reading. The capillary tube can be long. This lets you mount the dial somewhere convenient. You see the temperature on the dial face.
How does the gas-actuated system function?
A special gas fills the bulb and capillary. Temperature changes make the gas expand or shrink. This gas pressure moves the Bourdon tube inside the dial. The tube movement turns the pointer. The pointer shows the temperature on the scale.
What does the 1% accuracy mean?
It means the reading is very close to the real temperature. The maximum error is only 1% of the full scale range. For example, a 0-100°C scale has a possible error of ±1°C. This is good accuracy for industrial control.
Why is the capillary length important?
The capillary connects the sensing bulb to the dial. Longer capillaries let you measure temperature far away. Maybe the bulb is in a hot spot. You mount the dial where it’s safe to view. The length gives flexibility for installation. Choose the right length for your job.
What do the switch contacts do?
They are electrical switches inside the dial. You set them to specific temperatures. When the pointer reaches a set point, the contact opens or closes. This sends an electrical signal. Use this signal to control alarms, valves, or other equipment automatically.
REQUEST A QUOTE
RELATED PRODUCTS
Industry-leading Calibration Thermometer with Calibration Function Portable Design in Electronic Component Testing
Industrial temperature gauge bimetal thermometer China Manufacturer
Indoor Outdoor Home Use Digital Black LCD Thermometer Hygrometer Temperature
Digital Handheld 2-channel Thermistor Temperature Meter Sensor NTC Temperature Probe Thermometer for Industrial Quality Control
Industrial Thermometer With Stainless Steel Case OEM & ODM Support For Food Industry Temperature Instruments