Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer
These transformers take care of high power needs. They come in 1600kVA and 2500kVA sizes. They are air conditioning power transformers. They utilize oil for air conditioning and insulation. The oil is maintained inside a solid container. This layout works dependably for many years. They are built for constant operation. They power factories, big structures, or substations. They tip voltage up or down as required. They link straight to the power grid.
The main voltage fits your supply network. Usual scores are 11kV, 33kV, or others. The secondary voltage matches your equipment. It could be 415V, 6.6 kV, or different. The frequency is common 50Hz or 60Hz. Both versions feature an on-load faucet changer. This is a three-phase tap changer. It changes voltage while the transformer runs. You don’t need to shut down power. This keeps voltage steady. It compensates for grid changes. Guidebook or automated control is feasible. The tap range is generally ± 10% or ± 12.5%.
They utilize mineral oil for insulation and air conditioning. Radiators affix to the storage tank. Followers frequently cool down the radiators. This is ONAN/ONAF cooling. It handles the warmth from losses. The core uses grain-oriented silicon steel. This reduces thrown away energy. Copper or aluminum windings bring the existing. The container is bonded steel. It protects the core and windings. It holds the shielding oil. A conservator storage tank allows for oil expansion. A breather stops moisture entering the oil.
Safety gadgets are consisted of. A Buchholz relay detects interior mistakes. It causes an alarm or shutdown. A pressure relief valve avoids storage tank tear. Temperature level gauges monitor oil heat. Winding temperature level signs are likewise typical. They offer overload cautions. Links are via bushings on the tank. Wire boxes or busbar terminations are choices. The transformer abides by IEC criteria. Evaluating covers routine and type examinations. Impulse examinations check lightning defense. Temperature level surge examinations validate air conditioning. Loss dimensions guarantee effectiveness. Audio degree examinations guarantee peaceful procedure. Routine maintenance prolongs service life. Oil screening is important. Aesthetic assessments look for leaks.
Applications of 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer
These transformers take care of large power work. They work at 1600kVA or 2500kVA. They are air conditioning transformers. They remain real-time while adjusting voltage. They are loaded with oil for air conditioning and insulation. They have a three-phase faucet changer built in. This lets them alter voltage levels without quiting power.
They are built challenging for requiring locations. Manufacturing facilities use them a great deal. Equipments need steady power. Voltage goes down hurt production. These transformers deal with that. Huge structures need them too. Health centers, information centers, shopping malls all depend on stable power. Power quality matters right here. These units provide.
Mining websites use them. Mines have heavy equipment much from the grid. Voltage can droop. These transformers make up. They are additionally good for renewable resource tasks. Solar farms and wind parks attach to the grid. Grid voltage modifications. The tap changer maintains result stable. Water therapy plants rely on them. Pumps and filters run continuously. Constant voltage is crucial.
The oil inside cools the transformer. It also protects the windings. This layout handles hefty loads well. Heat is handled efficiently. The on-load faucet changer is crucial. Operators change taps while the transformer runs. Power never stops. This is vital for essential procedures. Downtime prices cash.
These devices provide adaptability. Voltage requires change. Grid conditions shift. The tap changer adapts quickly. Maintenance is easier. There is no requirement for a full closure to change voltage. Reliability is high. They are made for lengthy service in rough conditions. They solve genuine power stability issues.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 1600kva 2500kva AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer
Here are 5 FAQs for the 1600kVA/2500kVA AC On-Load Power Oil Immersed Transformer with Three Phase Tap Changer:
What is this transformer used for?
This transformer handles large amounts of electricity. It steps down high voltage power from the grid to a safer, usable level. Factories, big buildings, and industrial sites need it. It reliably powers heavy machinery and complex electrical systems.
Why choose the oil-immersed design?
Oil is better at cooling than air. It absorbs heat generated inside the transformer during operation. This keeps temperatures stable. Stable temperatures protect the internal parts. This design ensures long life and reliable power delivery under heavy loads.
What does the on-load tap changer do?
The tap changer adjusts the output voltage. It does this while the transformer is running. You don’t need to shut off power. This is vital. It keeps voltage steady even when the incoming power fluctuates. Equipment gets consistent power, preventing damage.
Is this transformer safe?
Safety features are built in. The tank is very strong. It holds the cooling oil securely. A pressure relief valve protects against internal pressure spikes. Fire barriers are standard. The oil itself helps insulate and suppress sparks. Regular maintenance checks are essential for ongoing safety.
What about installation and upkeep?
Installation needs careful planning. It’s large and heavy. You need a solid, level base. Good ventilation is important. Access for maintenance must be planned. Maintenance involves checking oil levels. Check oil quality too. Inspect connections and monitor the tap changer mechanism. Follow the manufacturer’s schedule strictly.
REQUEST A QUOTE
RELATED PRODUCTS
Factory 2025 New Supply 35KV Low Loss Transformer High Voltage 50KVA 80KVA 100KVA Oil Immersed transformers Customized
High Voltage Oil Immersed Distribution Transformer Single Three Phase Input Voltages 3kv 132kv Output 400v 11kv 50Hz 60Hz
Oil-Immersed MV&HV&LV Transformer with 10KV Input Voltage 400KV Output Voltage 50Hz-60Hz Frequency
Three Phase 3150-3000-6300 10000 /24000 /25000 /20000 KVA 115KV/10KV/132KV Input 440V/380V/11KV Oil Immersed Power Transformer
1250KVA 15/0.4KV Outdoor Compact Transformer Substation Ordinary Oil Immersed Transformer


