Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency
This 2000KVA oil-immersed power transformer deals with significant electrical tons. It steps down high voltage electricity for commercial and utility use. The primary voltage ranking is 10kV or 35kV. The second voltage result is 400V or 480V. This fits different local grid requirements.
It’s a three-phase transformer. Three-phase power is typical for heavy equipment and distribution networks. The layout utilizes a double-winding configuration. Main and secondary windings are separate coils. This isolation gives safety and versatility.
Building is durable. The core and windings rest inside a bonded steel tank. The tank is loaded with state-of-the-art insulating oil. This oil cools down the transformer. The oil likewise provides critical electrical insulation. Radiators placed on the storage tank enhance the cooling area. This guarantees effective warm dissipation throughout procedure.
Windings can be copper or light weight aluminum. Copper windings offer greater conductivity. They are typically much more efficient but cost more. Light weight aluminum windings supply a cost-efficient remedy. Both products ensure reliable efficiency under load.
The transformer runs at 50Hz or 60Hz frequency. This matches different global power systems. Resistance is enhanced. This limits power loss throughout voltage transformation. The system consists of essential safety features. Stress relief gadgets and temperature assesses are common. These monitor internal problems. They prevent damages from overloads or mistakes.
Installment requires a solid structure. Correct grounding is obligatory for security. Normal oil testing and maintenance checks are required. This assures long-lasting integrity and risk-free operation. This transformer provides dependable power conversion for requiring applications.
Applications of 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency
This 2000kVA oil-immersed power transformer actions down voltage. It attaches medium-voltage grids to your facility. It takes care of 10kV or 35kV input. It provides 400V or 480V result. This is standard for commercial power. The transformer works dependably. It uses oil for air conditioning and insulation. This layout is robust. It deals with challenging problems. The transformer lasts long. It serves critical power requirements.
Factories use this transformer typically. It powers big machines. Motors require stable voltage. Assembly line depend on it. Shops and mills need heavy power. This transformer gives it. It feeds entire workshops safely. Manufacturing plants rely on its capacity. It supports hefty electric loads.
Utilities deploy these transformers extensively. They sit in substations. They transform distribution voltage. They supply neighborhoods or commercial parks. The 10kV/35kV input fits common grids. The 400V/480V result feeds regional networks. It deals with peak need periods well. Grid security benefits from its design.
Big structures need considerable power. Shopping malls utilize this transformer. Workplace complicateds call for trusted electricity. Medical facilities require backup source of power. This system incorporates with important systems. It makes certain lights remain on. Air conditioning systems require steady voltage. This transformer provides it. Data facilities demand clean power. This transformer helps give it.
Renewable energy websites utilize it also. Solar ranches attach to the grid. Wind installments feed power back. This transformer tips up or down. It interfaces between generation and circulation. The double regularity (50Hz/60Hz) includes versatility. It functions worldwide. The copper or light weight aluminum winding choice uses price alternatives. Both conduct electrical power effectively. The oil insulation safeguards the windings. It stops electrical mistakes. Heat dissipation is reliable. This maintains efficiency. The transformer runs silently. It needs minimal maintenance.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 2000KVA Oil Immersed Power Transformer 10kV/35kV Three-Phase Double Winding 400V/480V Copper/Aluminum 50Hz/60Hz Frequency
What does 2000kVA mean?
2000kVA is the transformer’s power capacity. It shows how much electrical load it can handle. This size is common for large factories or substations needing substantial power. It supports heavy industrial equipment reliably.
What voltages does it work with?
This transformer steps high voltage down to low voltage. The primary side connects to 10kV or 35kV power lines. The secondary side outputs 400V or 480V. This supplies standard industrial machinery and plant distribution systems. It provides the right voltage for your equipment.
Why use oil immersion?
Oil immersion cools the transformer effectively. The oil absorbs heat from the windings and core. This prevents overheating during heavy use. Oil insulation also protects internal parts better than air. It makes the transformer durable for long-term outdoor or demanding indoor use. Oil types are stable and reliable.
Copper or Aluminum windings?
You can choose copper or aluminum windings. Copper windings conduct electricity better. They are slightly more efficient but cost more. Aluminum windings are lighter and cheaper. Both meet performance standards. The choice depends on your budget and specific efficiency targets. We offer both options.
Does it work at 50Hz and 60Hz?
Yes, this transformer is designed for both frequencies. It operates perfectly at 50Hz (common in Europe, Asia, Africa) and 60Hz (common in the Americas, parts of Asia). The core and design accommodate either frequency. You don’t need separate units for different power grids. It’s versatile for global projects.
REQUEST A QUOTE
RELATED PRODUCTS
750kva 1000kva 1200kva 1800kva 3000kva Threephase Power Electrical Transformers 11 Kv 415v OEM Supported Liquid-filled
UL Certification Transformers Providing Enhanced Performance for Industrial Applications, Advanced Oil-immersed Power
OEM 35KV Amorphous Alloy Oil Immersed Transformer Low Noise & High Performance for Industrial Use Made of Galvanized Steel
High Quality 3 Phase Oil Immersed Transformer 500kva 33kv 11kv Electrical Distribution Transformer