Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase
These 3-phase pad-mounted transformers take care of tool voltage power distribution. They tip down power securely. Common primary voltages are 34.5 kV. Usual secondary voltages are 13.2 kV or 13.8 kV. These devices are built for outdoor use. They rest on concrete pads. They provide power to neighborhoods, industrial areas, and commercial websites. The room is a secured metal box. This shields the devices. It keeps individuals secure.
Standard power scores are readily available. Options include 1000kVA, 1500kVA, 2000kVA, and 3000kVA. You may likewise see these detailed as 1MVA, 1.5 MVA, 2MVA, or 3MVA. Some references make use of MW (megawatt). These scores are comparable for this purpose. The appropriate dimension depends upon your load requires. These transformers take care of high power effectively. They link to underground wires. Main cables go into one side. Secondary cable televisions exit one more side. This configuration is cool and organized.
The enclosure is durable. It is generally steel. It stands up to climate and tampering. The box is full of dielectric oil. This oil cools the transformer. It shields the inner parts. Trick elements are within. The core and windings are immersed in oil. Bushings attach the wires. Faucet changers allow voltage adjustment. Devices are common. These consist of stress alleviation tools, gauges, and drains pipes. Safety and security attributes are necessary. The enclosure is based properly. Warning labels are clear. Pad-mounted transformers are dependable. They need little upkeep. They are designed for long life span. They are a common sight in energy networks. They supply power where expenses lines are unwise. They are crucial for modern below ground systems.
Applications of 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase
Three-phase pad-mounted transformers tip down high voltage power for regional use. Common rankings consist of 34.5 kV key voltage stepping down to 13.2 kV or 13.8 kV additional voltage. Requirement dimensions are 1000kVA, 1500kVA, 2000kVA, 3000kVA. These are likewise called 1MVA, 1.5 MVA, 2MVA, 3MVA, or about 1MW to 3MW capability. Their key benefit is dealing with large power loads securely and reliably in exterior setups.
These systems are crucial for contemporary power circulation. They provide electrical energy to large commercial buildings. Shopping malls, hospitals, office towers require substantial power. A 1500kVA or 2000kVA device usually manages this tons. It transforms the utility’s high voltage to usable degrees inside the structure.
Industrial facilities rely heavily on these transformers. Factories, making plants, handling centers use hefty machinery. Equipments need secure, high-capacity power. Transformers like 2000kVA or 3000kVA units give this. They link directly to the plant’s internal electrical grid.
Utility business deploy them widely in circulation networks. They feed entire communities or class. Below ground high-voltage line attach to the transformer. It decreases the voltage for homes and services nearby. Units like 1000kVA or 1500kVA serve smaller sized locations. Bigger 2500kVA or 3000kVA transformers serve dense urban zones or commercial parks.
Their pad-mounted design makes them perfect for these work. They sit securely on a concrete pad above ground. This conserves area contrasted to substations. It secures the inner components from climate and vandalism. Gain access to is very easy for upkeep staffs. Security attributes protect against public contact with live components. This allows installation near sidewalks, car park, or building wall surfaces. Reliability is crucial for continuous power supply. These transformers are built tough for long life span outdoors. They manage the high power needs of cities and industries successfully.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 3 Phase Pad Mounted Transformer 34.5 Kv 13.2kv 13.8kv 1000kva 1500kva 2000kva 3000kva 1500 3000 Kva 1mva 2 1.5 Mva 1mw 3phase
Here are 5 common questions about our 34.5kV/13.2-13.8kV 3-Phase Pad-Mounted Transformers (1000kVA, 1500kVA, 2000kVA, 3000kVA, 1MVA, 1.5MVA, 2MVA):
1. What is this transformer used for?
This transformer changes high voltage electricity to lower voltage electricity. It steps down power from 34,500 volts to either 13,200 volts or 13,800 volts. Utilities use it for neighborhoods and businesses. It provides power safely underground or overhead on local streets.
2. Where does this transformer go?
It sits on a concrete pad outside. You see it near buildings, shopping centers, or housing developments. The steel enclosure protects the internal parts. It connects directly to underground power cables. This keeps things safe and tidy above ground.
3. What do kVA, MVA, and MW mean for these sizes?
kVA, MVA, and MW tell you the transformer’s power capacity. 1000 kVA equals 1 MVA. 1500 kVA is 1.5 MVA. 2000 kVA is 2 MVA. 3000 kVA is 3 MVA. MW (Megawatt) is similar for real power. Our transformers handle 1000kVA (1MVA), 1500kVA (1.5MVA), 2000kVA (2MVA), and 3000kVA (3MVA). Pick the size matching your load needs.
4. Why are there two different low voltages (13.2kV and 13.8kV)?
Different power systems use slightly different standard voltages. 13.8kV is very common. Some systems use 13.2kV. Our transformers are built for either voltage. You specify which low voltage your project requires. The transformer is designed for that exact output.
5. How much maintenance does it need?
These transformers are built for low maintenance. The sealed tank protects the oil and core. Regular visual checks are important. Look for leaks, damage, or overheating signs. Oil testing and internal inspections are needed periodically. Always follow the utility company’s specific maintenance schedule. Professionals must handle this work.
REQUEST A QUOTE
RELATED PRODUCTS
TSTY 3 Phase Voltage Transformer Oil Immersed Transformer 11kv 33kv 50kva 100kva 200kva 300kva 220v to 380v Step up Transformer
Customized 12500KVA 20000KVA Electric Transformer 35KV 10.5KV Pure Copper Oil Immersed Three Phase 10KV Input Voltage 380V
SH15 Series 30-2500KVA 6-11KV Three Phase Amorphous Alloy Fully Sealed Oil Immersed Power Transformer
High Efficiency 50MVA 110KV Oil Immersed Transformer For Energy Projects And Smart Grid
11 13 14 MVA 12500 KVA 13000kVA 3 Phase Electrical Oil Immersed Power Transformer


