Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA
These electric transformers handle power distribution efficiently. They are three-phase oil-immersed types. The capability range is vast, from 20kVA approximately 5MVA. They fit various applications needing trusted voltage improvement.
Common voltage ratings include 11kV/0.4 kV, 33kV/0.4 kV, and others. Criterion frequencies are 50Hz or 60Hz. Mineral oil fills up the storage tank. This oil cools the transformer and protects the windings. The core uses high-grade silicon steel. This steel decreases power wasted as warmth.
Reduced loss is a significant feature. Both no-load loss and tons loss are significantly reduced. This saves energy prices over the transformer’s life time. The design focuses on high performance. Reduced operating temperature levels result. This extends the equipment’s life span.
A bonded steel tank holds the core and windings. Radiators affix to the storage tank. These radiators dissipate warmth properly. Some designs include an expansion conservator. This conservator holds additional oil. It allows for oil quantity adjustments with temperature.
Setup choices are versatile. These transformers function well inside your home or outdoors. They handle diverse environments accurately. Temperature increase limitations are plainly specified. The maximum oil temperature level surge is typically 55K. The maximum winding temperature increase is generally 65K. Solid insulation systems ensure safety and sturdiness.
Security functions are basic. Pressure alleviation devices prevent tank overpressure. Oil degree evaluates display oil quantity. Thermostats track operating temperature level. Drain pipes valves enable oil tasting and substitute.
These devices power manufacturing facilities, industrial structures, and country networks. They step down high voltage for neighborhood use. Their robust construct makes sure trustworthy operation. Routine upkeep is straightforward.
Applications of Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA
These reduced loss 3 stage oil immersed distribution transformers manage power efficiently. They relocate power between circuits. Transformers change voltage levels. They are crucial for supplying power securely. This kind uses oil for cooling and insulation. The oil maintains the transformer cool throughout procedure. Good cooling protects against getting too hot. Overheating problems devices. The oil additionally insulates electric parts. This prevents short circuits.
These transformers function from 20kVA up to 5MVA. This array matches many needs. They connect to medium voltage networks. They step down voltage for neighborhood use. Manufacturing facilities, industrial buildings, and real estate estates use them. Renewable energy sites like wind ranches need them too. Mining operations need durable power distribution. These transformers fit well there.
The “low loss” layout is an essential benefit. It means much less squandered energy. Less power lost as heat conserves cash. It lowers operating costs substantially with time. Reduced losses likewise mean higher efficiency. Effective transformers are better for the environment. They eat less gas in general. This supports sustainability objectives. Utilities and businesses choose effective tools.
The oil immersed layout is proven and trustworthy. It manages high power needs continuously. The storage tank shields interior parts. This makes sure long service life. Upkeep is simple. Technicians can inspect oil degrees and problem conveniently. These transformers withstand challenging problems. They run reliably outdoors or in substations. Their robust building and construction reduces failures. Power interruptions are expensive. Reliability is important. This style delivers reputable performance every year. It powers areas and markets successfully.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of Electric Transformers Low Loss Three Phase Oil Immersed Distribution Power Transformer 20kva-5MVA
Here are five common questions about our low loss three phase oil immersed distribution power transformers (20kva-5MVA):
What makes this transformer “low loss”?
Our design significantly cuts down wasted energy. We use top quality grain-oriented silicon steel for the core. This reduces no-load loss. No-load loss happens when the transformer is plugged in but not powering equipment. We also optimize the windings. This lowers load loss. Load loss occurs during actual power delivery. Lower losses mean lower electricity bills over the transformer’s life.
What capacity range do these transformers cover?
We offer these transformers from 20 kilovolt-amperes (kVA) up to 5 megavolt-amperes (MVA). This range suits many distribution needs. Common uses include powering factories, commercial buildings, housing complexes, and renewable energy connection points. Tell us your specific voltage and power requirements. We find the right size unit for you.
How is this transformer installed?
Installation needs careful planning. The transformer arrives filled with insulating oil. It is heavy. Ensure your site has a strong, level foundation. Proper lifting equipment is essential. Connect the high voltage and low voltage terminals correctly. Follow all safety codes. Qualified electrical personnel must handle installation and commissioning. We provide detailed installation manuals.
What maintenance is required?
Regular checks keep the transformer reliable. Visually inspect the tank for leaks. Monitor the oil level using the gauge. Check the oil temperature. Sample the insulating oil periodically. Lab analysis finds moisture or breakdown products. Clean the radiators to prevent overheating. Keep the area around the transformer clear. Follow the maintenance schedule in the manual. Major internal work needs specialists.
Are these transformers safe?
Safety is critical. The robust steel tank protects the core and windings. The insulating oil cools the unit. It also prevents electrical arcing. Units include a conservator tank. This allows oil to expand and contract safely. A breather stops moisture entering the oil. Pressure relief devices guard against internal faults. Buchholz relays detect gas from internal problems. They trigger an alarm or shutdown. Always follow electrical safety procedures.