1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.

Features of 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.

Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.

Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.

Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.

Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.

Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.

Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.

Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.

Specifications of 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

These transformers handle solar farm connections. They connect to 12.47kV distribution lines. Capacities are 1000kVA, 1500kVA, 2000kVA, and 2500kVA. They are pad-mounted oil transformers. This design is safe and reliable. Two feed styles are available: loop feed and radial feed. Loop feed allows power flow in two directions. Radial feed is for one-way power flow. Choose the feed style matching your system layout.

The transformers use high-grade insulating oil. This oil cools the core and windings effectively. The enclosure is robust steel. It protects against weather and tampering. All units meet strict safety standards. UL and CSA certifications are standard. The primary voltage is 12.47kV. The secondary voltage is typically 600V or 480V. This matches common solar inverter outputs. Voltage taps are included. These taps adjust for minor line fluctuations. This ensures stable output voltage.

The core uses high-quality electrical steel. This minimizes energy losses. Efficiency is a priority for solar applications. Lower losses mean more power delivered. The units are designed for outdoor use. They handle temperature extremes well. Maintenance needs are low. Oil levels and bushings require periodic checks. The transformers provide reliable power transfer. They are built for the demands of solar generation. Terminations are clearly labeled. This simplifies installation and connection. Primary bushings are suitable for cable or overhead line entry. Secondary bushings accept large cables.

Applications of 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

These transformers connect large solar farms to the utility grid. They step up the voltage generated by the solar panels. The standard voltage is 12.47kV. This matches common distribution lines. Units range from 1000kVA to 2500kVA. This capacity handles significant solar power output. Oil cooling manages the heat. This is essential for reliable, continuous operation outdoors.

The loop feed design provides a key advantage. It allows power to flow from two directions. This setup maintains power delivery. It happens even during maintenance or a fault on one line. The loop feed boosts grid reliability. It minimizes downtime for the solar installation. This is critical for large-scale energy production.

The radial feed option is simpler. It connects the transformer to a single utility source. This design works well for straightforward connections. It suits locations where redundancy isn’t the primary concern. Radial feed installations are often more economical initially.

Both loop feed and radial feed transformers are pad-mounted. This means they sit securely on a concrete foundation. Pad mounting keeps the equipment grounded and stable. It protects internal components from weather and environmental damage. The enclosure is robust and tamper-resistant. This ensures safety for the public and maintenance crews. The design allows for easy access by utility personnel when needed.

These transformers handle the intermittent nature of solar power. They manage the daily cycles of generation. They are built tough for constant outdoor exposure. Heat, cold, rain, and dust are expected conditions. Oil insulation and cooling systems handle these demands effectively. The robust construction ensures a long service life. Reliability is non-negotiable for solar farm operators. Downtime directly impacts energy sales and grid contracts. These units deliver the necessary performance. They form a vital link between renewable solar generation and the existing power grid infrastructure.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of 1000kVA/1500kVA/2000kVA/2500kVA 12.47kV Solar Transformer with Loop Feed Radial Feed Oil Transformer Pad Mounted Transformer

What does this transformer do?
It connects solar farms to the power grid. It takes the high voltage electricity from the solar panels. It changes the voltage to match the grid’s 12.47kV level. This lets the solar power flow safely into the utility system.

What are the main features?
This transformer handles large solar installations. It comes in 1000kVA, 1500kVA, 2000kVA, and 2500kVA sizes. It uses oil for cooling and insulation. It is built inside a strong metal tank. This tank sits on a concrete pad outdoors. It protects the parts inside from weather and damage.

What’s the difference between Loop Feed and Radial Feed?
Loop Feed transformers have two power sources. This means power can come from either direction. If one source fails, power can often switch to the other side. This keeps the system running. Radial Feed transformers have only one power source. Power flows in one direction only. There is no backup source built into the transformer connection.

Is it safe?
Yes, safety is important. The tank is sealed and robust. It contains any internal oil. It stops leaks. The transformer has secure doors and locks. This keeps people out. It prevents accidental contact with high-voltage parts. It meets strict safety standards for utility equipment.

How is it installed?
Installation needs a prepared concrete pad. The pad must be level and strong. The transformer gets placed directly onto this pad. Connections for high-voltage cables and grounding are made outside the tank. The location must allow good air flow around the unit. It needs space for utility workers to safely access the cables and switches.

REQUEST A QUOTE