Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V
3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.
Features of 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V
Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.
Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.
Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.
Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.
Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.
Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.
Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.
Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.
Specifications of 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V
These transformers distribute power underground. They step down high voltages for local use. Common primary voltages include 34.5kV, 13.2kV, and 13.8kV. The secondary output is typically 380V. Some units also handle 220kV input. Power ratings vary to meet different needs. Standard sizes are 1000kVA, 1500kVA, 2000kVA, and 3000kVA. These match 1MVA, 1.5MVA, 2MVA, and 3MVA. The 1000kVA unit equals 1MW capacity. The 1500kVA and 3000kVA models are also popular. These transformers are built tough. They sit directly on concrete pads. This design saves space. It protects the internal parts. They withstand outdoor conditions. Weather protection is excellent. Rain, snow, and sun cause no problems. The enclosure is tamper-resistant. Safety is a priority. Access requires special tools. This prevents accidental contact. Internal components are high quality. The core uses efficient electrical steel. Windings are copper or aluminum. They are designed for low losses. Insulation is liquid-filled. This provides cooling and protection. Temperature rise is controlled. Overload capacity is reliable. These units connect easily. Primary and secondary cables enter through bases. Bushings are accessible inside. Grounding points are clearly marked. Maintenance is straightforward. Oil level gauges are visible. Pressure relief devices are standard. Fault indicators may be included. Installation follows utility standards. These transformers serve many places. They power neighborhoods and businesses. They run industrial parks and hospitals. Reliability is critical. They offer long service life. Performance meets industry expectations. Choose the size matching your load. Consider the primary voltage available. Check the secondary voltage required. The enclosure rating must suit the location. These specifications guide your selection.
Applications of 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V
Pad-mounted transformers change high voltage electricity to safer lower levels. They handle inputs like 34.5Kv, 13.2Kv, or 13.8Kv. They step this down to common voltages like 220Kv or 380V. Units come in different power ratings. Common sizes are 1000Kva (1Mva), 1500Kva (1.5Mva), 2000Kva (2Mva), and 3000Kva (3Mva or about 1Mw). You see these transformers in many places. They are vital in city neighborhoods. They feed power to groups of homes or apartment buildings. A 1000Kva or 1500Kva unit often does this job well. They are also essential for businesses. Shopping centers, office parks, and hospitals need reliable power. Larger units like 2000Kva or 3000Kva support these bigger loads. Factories and industrial plants use them too. Machines need steady lower voltage power. Transformers rated 1500Kva to 3000Kva handle heavy industrial demands. They keep production lines running. These transformers work well with renewable energy projects. Solar farms or wind installations generate power. They connect to the grid using pad-mounted transformers. The transformer adjusts the voltage for transmission. The compact design is a big advantage. They sit directly on a concrete pad. This saves space compared to bigger substations. They fit neatly into urban areas or tight industrial sites. Safety is another key point. The metal enclosure protects the internal parts. It keeps people and animals safe from high voltage. It also protects the transformer from weather and damage. Maintenance is simpler. Technicians can access them easily for checks or repairs. Utilities and companies choose these transformers for reliability. They provide power safely and efficiently. They are the backbone for distributing electricity where people live and work. They are also crucial for running factories and connecting green energy.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 3 Pad Mounted Transformer 34.5Kv 13.2Kv 13.8Kv 1000Kva 1500Kva 2000Kva 3000Kva 1500 3000 Kva 1Mva 2 1.5 Mva 1mw 220Kv 380V
What exactly do these pad-mounted transformers do?
They change high-voltage electricity from power lines (like 34.5kV, 13.2kV, or 13.8kV) down to much safer, usable low voltage (like 380V). This powers homes, businesses, and neighborhoods safely. They handle different power levels: 1000kVA (1MVA), 1500kVA (1.5MVA), 2000kVA (2MVA), or 3000kVA (3MVA/3MW).
Where do you usually install these transformers?
You see them at ground level beside streets, in parking lots, or near buildings. They sit on a concrete pad. Their green metal box blends into landscapes. This location is convenient for utility crews. It keeps high voltage away from people.
Are these transformers safe around people?
Yes, safety is critical. The live electrical parts are locked inside a sturdy, tamper-proof steel enclosure. Only utility workers with special tools can open it. The box is grounded properly. Warning labels are clear. This design prevents accidental public contact.
How do I pick the right size (kVA/MVA)?
Match the transformer size to the power needed. A 1000kVA (1MVA) unit suits smaller areas or groups of homes. A 1500kVA (1.5MVA) handles more. Choose 2000kVA (2MVA) or 3000kVA (3MVA/3MW) for large commercial buildings, factories, or dense neighborhoods. Consider future growth too.
What maintenance do they need?
These transformers need regular checks. Utility crews inspect them for oil leaks, damage, or overheating. They test the oil quality and electrical connections. The enclosure needs checking for rust or corrosion. Proper maintenance ensures long life and reliable power.