3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.

Features of 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.

Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.

Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.

Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.

Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.

Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.

Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.

Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.

Specifications of 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

This 3500 kVA grounding transformer connects directly to 34.5 kilovolt power lines. It steps down this high voltage to safer, usable levels. You get two standard low-voltage outputs: 415 volts and 480 volts. This flexibility suits different equipment needs on site. The unit handles both major global power frequencies, 50 Hertz and 60 Hertz. It works reliably wherever you install it.

The transformer is pad-mounted. This means it sits securely on a concrete slab outdoors. Its sturdy steel enclosure protects all internal components. This design withstands tough weather conditions. The enclosure keeps people safe from high voltage parts inside. Access is restricted to qualified personnel only. Maintenance points are clearly marked for service crews.

Inside, high-quality copper windings ensure efficient power transfer. These minimize energy losses during operation. The core uses premium electrical steel. This design reduces noise and heat generation. Reliable cooling systems maintain optimal temperatures. This happens even under continuous full load. The transformer uses proven insulation materials. These guarantee long-term performance and safety.

The unit includes essential grounding features. It provides a stable neutral point for the electrical system. This protects equipment from voltage surges. It enhances overall system safety. The design meets strict international safety standards. It carries recognized certifications for electrical equipment. These ensure compliance in most regions.

Installation is straightforward for trained technicians. The pad-mount design saves space compared to larger substation transformers. It fits well in commercial areas or industrial sites. Connections for the high-voltage cables and low-voltage outputs are clearly designated. Terminals are robust for secure wiring. The transformer arrives ready for connection after basic site preparation. It requires minimal setup before commissioning. Routine maintenance checks keep it running efficiently for years.

Applications of 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

This 3500 kVA pad-mounted transformer handles 34.5 kV input. It provides a solidly grounded neutral for the system. This grounding is vital for safety and stable operation. The transformer delivers power at two common low voltages: 415V and 480V. It works reliably with both 50Hz and 60Hz electrical systems. This flexibility makes it suitable for many global applications.

It serves critical roles in electrical distribution networks. You often find it stepping down voltage for industrial parks or large commercial complexes. The unit feeds power reliably to heavy machinery, lighting, and HVAC systems. Its pad-mounted design is important. This means it sits securely on a concrete pad at ground level. This setup is safer and easier to access than pole-mounted units. It saves space too.

Renewable energy projects use this transformer extensively. It connects solar farms or wind turbine arrays to the medium-voltage grid. The transformer adjusts the voltage efficiently. It handles the variable power output common in renewables. The dual voltage outputs (415V and 480V) are a major benefit. Facilities can use the same transformer model for different internal equipment needs. This simplifies inventory and installation.

Industrial facilities rely on its robust grounding capability. This protects sensitive manufacturing equipment from voltage surges and faults. Factories need stable, clean power. This transformer helps provide that. Data centers also utilize these units. They ensure continuous, high-quality power for servers and cooling systems. The 3500 kVA capacity is significant. It supports large power demands effectively.

The ability to operate at both 50Hz and 60Hz is crucial. It allows deployment in diverse international markets. Projects in Europe, Asia, or the Americas can use the same unit. This reduces design complexity and sourcing challenges. The transformer offers a dependable solution for stepping down high voltage safely. It delivers versatile power where it’s needed most.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of 3500 Kva 34.5 Kv Grounding Transformer Pad-Mounted with 415V & 480V Output Three Phase 50Hz & 60Hz Frequency

What does this transformer do?
This unit protects equipment and people. It provides a safe grounding point for 34.5kV systems. It also transforms that high voltage down to usable 415V or 480V power. It feeds machinery and facilities needing three-phase electricity.

What voltages does it handle?
It connects directly to 34.5 kilovolt power lines. Inside, it steps this down. You get two separate low voltage outputs: 415 volts and 480 volts. Both outputs are three-phase. You choose the voltage needed for your specific equipment.

Will it work with 50Hz and 60Hz power?
Yes. The transformer is built for both frequencies. It operates correctly whether your local grid uses 50Hz (common in many countries) or 60Hz (common in North America). You don’t need different models.

Why is it pad-mounted?
Mounting it on a concrete pad keeps it secure and safe outdoors. This design protects the transformer from weather and accidental contact. It saves space inside buildings. Installation and maintenance are simpler outside. The enclosure is tough and lockable.

How does it stay cool?
This is a dry-type transformer. It uses air for cooling. There is no oil inside. This makes it safer and cleaner. It reduces fire risk and avoids messy leaks. Air flows naturally or with fans around the coils to manage heat.

REQUEST A QUOTE