500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.

Features of 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.

Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.

Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.

Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.

Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.

Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.

Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.

Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.

Specifications of 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

This 500kVA pad-mounted transformer handles 15,000 volts primary voltage. It steps down power to 600 volts second voltage. This device fulfills stringent ANSI/IEEE criteria. It’s constructed for reputable service in utility power networks. The transformer is mounted outdoors on concrete pads. Its durable steel enclosure shields internal elements. The unit includes bolted accessibility doors. These doors make maintenance much easier. The unit is weatherproof. It stands up to corrosion successfully. The style includes loop feed capability. Loop feed allows power circulation in 2 directions. This supplies versatility in network layouts. The transformer additionally supports radial feed procedure. Radial feed is a less complex, one-way power path. Both feed options make use of separable shielded ports. These connectors boost safety during procedure. The key bushings are rated 15kV. The second bushings are rated 600V. Basic insulation degree (BIL) is 95kV for the main side. This supplies great lightning surge security. The secondary side BIL is 30kV. The transformer uses top notch electric steel core. Copper windings ensure efficient power transfer. It consists of pressure alleviation gadgets. These safeguard against interior overpressure. A fluid degree scale keeps an eye on the dielectric fluid. The unit features lifting stipulations. This simplifies installment and handling. Requirement devices are readily available. These include lightning arresters and protective cabinets. The transformer is filled with mineral oil. This oil provides insulation and air conditioning. The device is developed for long life. It operates reliably under regular problems. Regular maintenance checks are recommended. This makes sure ongoing secure efficiency. The transformer connects straight to distribution wires. It interfaces with the energy grid dependably. Safety is a key focus. No online parts are subjected outside the unit. The style decreases fire hazards. It fulfills market security requirements totally. The transformer handles regular distribution loads well. Its size suits commercial and light commercial applications.

Applications of 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

This transformer delivers trustworthy power circulation. It manages 500kVA capability at 15,000 volts. It adheres to rigorous ANSI/IEEE requirements. This guarantees compatibility and safety. Energies trust fund this layout. It fits completely right into loop feed systems. These systems create interconnected rings. Power flows numerous courses. This transformer is a vital link factor. Blackouts affect less customers. Service reliability boosts dramatically.

It likewise excels in radial feed networks. These are less complex branch-like layouts. Power takes a trip one main path exterior. This transformer functions as a circulation center. It tips down the high voltage. Power comes to be usable for areas. It’s built for outdoor ground placing. The tough, locked steel room protects interior parts. Tampering is hard. Weather condition damages is decreased. This transformer functions well near structures. It powers going shopping centers properly. It supplies workplace parks accurately. Manufacturing facilities use its stable power result.

Communities take advantage of its installment. It feeds power to groups of homes. Industrial sites need its robust performance. It supports heavy machinery operation. The layout focuses on safety. Automatic security systems turn on during faults. This protects against equipment damages. Maintenance crews gain access to it conveniently. Routine checks are straightforward. Decreased downtime conserves money. The transformer fulfills important grid demands. It supplies regular electricity circulation. Urban settings appreciate its small impact. Backwoods depend upon its longevity.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of 500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer

Here’s what people often ask about 500kVA 15kV ANSI/IEEE pad-mounted transformers for loop or radial feeds:

What exactly is this transformer? It’s a power transformer inside a locked metal box sitting on a concrete pad. It handles 500,000 volt-amps. It steps down 15,000-volt distribution power to usable lower voltages for buildings or neighborhoods. It meets strict ANSI/IEEE safety and performance rules.

What’s the difference between loop feed and radial feed? A loop feed transformer has two high-voltage connections. Power can flow into it from either side. This creates a continuous loop in the circuit. Other transformers down the line stay powered if one section fails. A radial feed transformer has only one high-voltage input. Power flows straight in one direction. It’s simpler. A fault upstream cuts power to everything downstream.

Why use one over the other? Choose loop feed when keeping power on is critical. Hospitals or data centers often need this reliability. Choose radial feed for simpler, cheaper installations where brief outages are acceptable. Think residential areas or smaller businesses.

How safe is it? Very safe. The steel enclosure is tamper-proof and locked. You need special tools to open it. The design prevents accidental contact with live parts inside. All metal parts connect solidly to earth ground. This protects people from shock if something goes wrong.

What about putting it in and keeping it running? Installation needs trained crews. They dig the hole, set the concrete pad, place the transformer, then connect the high-voltage cables and low-voltage output cables correctly. After installation, check it visually sometimes. Look for oil leaks. Listen for unusual humming or buzzing noises. Get professional maintenance checks yearly. They test the oil and inspect internal parts.

REQUEST A QUOTE

REQUEST A QUOTE