Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.

Features of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.

Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.

Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.

Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.

Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.

Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.

Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.

Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.

Specifications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad-mounted transformers provide trusted power for commercial and industrial requirements. These systems tip down higher circulation voltages to functional degrees. Common options consist of 13.2 kV, 23kV, and 35kV main voltages. Standard abilities are 75kVA, 112.5 kVA, 160kVA, and as much as 500kVA. This range covers several applications properly.

The transformer sits firmly inside a durable, weatherproof steel unit. This unit is developed for ground-level setup straight on a concrete pad. It safeguards the core and coil assembly inside. This configuration maintains the transformer risk-free outdoors. It withstands extreme weather conditions year-round.

Safety is critical. These transformers feature tamper-proof styles. Locking doors avoid unapproved accessibility to live components. This shields people and building. The rooms likewise fulfill certain security standards. They are developed difficult for public areas near structures or car park.

Performance issues for cost financial savings. Modern pad-mounted transformers use top notch core steel and windings. This reduces power losses during operation. Reduced losses mean reduced electrical power costs over the transformer’s lengthy lifespan. They operate reliably for several years.

Setup is straightforward. The pad-mounted layout removes the need for posts or devoted frameworks. It conserves area and streamlines website preparation. Energies and services appreciate this functional service. Upkeep gain access to is additionally practical through the enclosure doors. Specialists can perform assessments and service quickly.

These transformers connect cleanly to underground power line. They develop a vital web link in between the utility grid and the end-user’s electric system. Typical uses include shopping mall, colleges, factories, and workplace parks. They give the needed power step-down successfully. The specific voltage and kVA ranking is chosen based upon the tons requirements. Correct sizing ensures optimal efficiency and durability.

Applications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad installed transformers deal with important power tasks. They tip down greater voltage electrical energy to levels risk-free for everyday use. You see them commonly in communities. They provide power to groups of homes or apartment. These systems prevail. They sit on concrete pads right at ground level. This makes them protected and easy to reach for solution. Their hard steel cases shield the equipment inside from climate and people touching them. They are built for outside use.

Services rely on these transformers also. Shopping centers use them. Office buildings require them. They supply the appropriate power for lights, computer systems, and machines. Manufacturing facilities set up pad placed transformers. They power heavy devices dependably. Medical facilities depend upon them for important treatment locations. Places requiring constant power pick these systems. They are dependable.

Various sizes exist for different requirements. Smaller systems, like 75kVA or 112.5 kVA, typically serve tiny industrial buildings or a couple of houses. Larger sizes, like 160kVA or 500kVA, deal with larger loads. They power bigger shops, bigger groups of homes, or commercial devices. The voltage issues. Systems rated for 13.2 kV, 23kV, or 35kV link to various power lines located in different locations. This flexibility is crucial.

Renewable resource jobs use pad installed transformers. They link solar farms or wind turbines to the grid. The power produced needs transforming. These devices do that work well. They match limited areas conveniently. Their small layout is a big advantage. They maintain the power streaming securely. They are a vital part of the electric system.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer , please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Check your voltage first. Pad mounted transformers handle different primary voltages like 13.2kV, 23kV, or 35kV. You must pick the exact voltage your power line uses. These voltages are not interchangeable. Getting the voltage wrong causes major problems.

How big a transformer do you need? Sizes like 75kVA, 112.5kVA, 160kVA, and 500kVA are common. Choose based on your actual power demand. Don’t guess. Look at your peak electrical load. Picking a transformer too small overloads it. Picking one too big wastes money. Match the kVA rating to your measured load.

Safety matters. These units are built tough. They sit outside near people. Expect strong, tamper-proof steel enclosures. Doors lock securely. Internal designs often resist electrical arcs. Good ventilation prevents overheating. The design keeps the public safe.

Maintenance is usually low. These transformers are sealed units. You don’t service them daily. Routine checks are essential. Look for oil leaks. Listen for unusual humming sounds. Check cooling fins aren’t blocked. Monitor the temperature gauges. Keep the area around the transformer clear. Professional inspections every few years are smart.

Installation needs planning. The transformer sits on a solid concrete pad. The pad must be perfectly level. It must support the heavy weight. Leave enough space all around. Workers need room for safe cable connections. Workers need room for future checks. Follow the manufacturer’s spacing rules exactly. Proper clearances prevent accidents.

REQUEST A QUOTE

REQUEST A QUOTE