High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories

Transformer accessories refer to various auxiliary equipment or materials used in conjunction with transformers to assist them in achieving their functions. High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories is crucial for the regular operation of transformers, as they can ensure stable operation under various environmental conditions and improve the efficiency and reliability of transformers. At the same time, the mintenance and upkeep of transformer accessories are also important links to ensure the normal operation of transformers, and regular inspections and replacements are needed to ensure their normal operation. Transformer accessories are essential auxiliary equipment and materials for the regular operation of transformers and are of great significance for stable operation and efficiency.

Transformer Accessories Mainly Include the Following Types

Transformer oil: used for insulation and cooling.

Transformer oil conservator: stored transformer oil and maintained a stable oil level.

Radiator: Used to transfer the heat generated by the transformer to the surrounding air and maintain stable transformer temperature.

Respirator: used to regulate the internal gas pressure of the transformer and prevent deformation of the transformer oil tank.

Explosion-proof tube: used to prevent the gas and oil flow generated in the event of internal faults in transformers from spraying out.

Insulation sleeve: used to protect the windings and leads of transformers, preventing electric shock and short circuits.

Thermometer: used to monitor the temperature of transformers and detect abnormal situations promptly.

Gas relay: used to monitor the pressure and temperature of the gas inside the transformer and detect faults promptly.

Voltage and current transformers: Used to convert transformers’ voltage and current signals into measurable electrical signals.

Lightning arrester: used to protect transformers from lightning and overvoltage impacts during operation.

Specifications of High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories

The PRD 50 Air Qualitrol Pressure Relief Valve is a key transformer accessory. It protects oil-filled transformers and similar equipment. It prevents dangerous pressure build-up. Internal faults create excess pressure. This valve releases that pressure fast. It stops tank rupture and serious damage.

This valve handles pressures from 2 PSI to 15 PSI. You set the exact opening pressure during installation. It opens precisely at the chosen pressure. It reseals tightly when pressure drops safely. This resealing happens automatically. It keeps transformer oil inside the tank. It prevents air and moisture from getting in. This protects the insulating oil.

The valve body uses strong stainless steel. Internal metal parts are brass. These materials resist corrosion well. They ensure long life. The valve includes a weatherproof housing. This housing shields the mechanism. It works reliably in tough outdoor conditions. Rain, snow, dust won’t stop it.

Installation is straightforward. You mount it on the transformer tank. It connects to the air space above the oil. You see the valve position easily. An external indicator shows OPEN or CLOSED. This allows quick visual checks. Maintenance needs are very low. It’s a dependable safety device.

This valve meets important standards. It follows IEEE C57.12.00 and IEEE C57.12.90 guidelines. It also complies with ANSI/IEEE C37.91. These certifications confirm its reliability. It’s built for consistent performance. Its job is critical safety.

Applications of High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories

High pressure inside transformers is dangerous. The PRD 50 Air Qualitrol Pressure Relief Valve stops this danger. It protects transformers from exploding or catching fire. This valve is vital for transformer safety. It works on oil-filled transformers.

Sudden pressure rises happen inside transformers. Electrical faults cause this. Overloading causes this too. The valve senses this pressure fast. It opens instantly. The valve releases the extra pressure. It lets the high-pressure oil escape safely. This stops the transformer tank from breaking. It prevents oil fires. The valve resets itself automatically. Pressure drops back to normal. The valve closes tight. The transformer keeps working safely. No manual reset is needed. This is a big advantage.

The PRD 50 valve is common in power grids. Utilities use it. Industries use it. It protects large power transformers. It protects smaller distribution transformers too. You see it on substation transformers. You see it on industrial plant transformers. The valve is reliable. It activates quickly every time pressure gets too high. Its design is simple. This makes it dependable for long periods. Maintenance is easy. The valve uses a proven spring and diaphragm mechanism. This mechanism is strong. It handles tough conditions. It works in extreme cold. It works in extreme heat. The valve seals well after operation. It prevents oil leaks. It prevents air getting inside the transformer tank. Keeping air out is important. Air harms the transformer oil. The valve helps maintain oil quality. This protects the transformer’s insulation system. Good insulation is critical for transformer life. The PRD 50 valve is a key safety accessory. It is installed on the transformer tank. It provides essential protection against pressure disasters.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of High Pressure Safety Valve Prd 50 Air Qualitrol Pressure Relief Valve Transformer Accessories

People often ask what the High Pressure Safety Valve Prd 50 Air Qualitrol does. It protects transformers from dangerous pressure build-up. Too much pressure inside a transformer tank can cause serious damage. This valve opens automatically when pressure gets too high. It vents the excess pressure safely. Then it reseals tightly once pressure drops back to normal.

Another common question is why transformers need this specific valve. Air trapped inside the transformer tank is the main problem. Air expands much more than oil when heated. This expansion creates high pressure very quickly. The Prd 50 valve reacts fast to this rapid air pressure increase. It prevents the tank from rupturing or leaking.

Many users want to know how this valve actually works. The valve has a precise spring mechanism. Normal operating pressure keeps the valve firmly shut. Pressure exceeding the preset limit overcomes the spring force. The valve disc lifts off its seat. This releases the trapped air. Pressure drops. The spring pushes the disc back down. The valve seals again.

People ask how often this valve needs checking. Regular inspection is crucial. You should visually inspect the valve at least once a year. Look for any signs of damage or leakage. Test the valve mechanically every few years. Follow the manufacturer’s guidelines for testing frequency. Proper maintenance ensures the valve works when needed.

A final question is about installing the Prd 50 valve. Correct installation is vital. Place the valve on the highest point of the transformer tank. This spot collects trapped air. Ensure the mounting flange is clean and level. Tighten the bolts evenly according to the torque specs. Never block the valve outlet. It must vent freely.

REQUEST A QUOTE