Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer
13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.
Features of 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer
Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.
Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.
Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.
Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.
Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.
Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.
Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.
Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.
Specifications of 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer
Below’s the transformer info:
This pad-mounted transformer deals with tool voltage power circulation. It tips down greater circulation voltages to useful degrees for buildings or centers. Key voltage scores are 13.8 kV, 13.2 kV, and 12.47 kV. These voltages match usual utility circulation systems. The transformer operates on three-phase power. This is the criterion for industrial and industrial power supply.
Offered abilities consist of 250kVA, 300kVA, 400kVA, 630kVA, and 750kVA models. The 250kVA and 300kVA devices match smaller sized commercial loads or groups of homes. The 400kVA dimension manages larger shops or light industrial applications. The 630kVA and 750kVA transformers support considerable facilities like manufacturing facilities, health centers, or large apartment complexes. Choose the kVA score based on your complete electrical tons needs.
The transformer utilizes a delta main winding link. The secondary winding utilizes a wye connection. This gives a neutral factor for grounding. The core and coils sit inside a robust steel tank. This tank is loaded with top-quality mineral oil. The oil insulates and cools down the windings properly. The external unit is weatherproof. It withstands severe outdoor problems. The room is corrosion-resistant. It shields the interior components.
This transformer mounts firmly on a concrete pad. The pad rests at ground degree. This setup technique is risk-free. It maintains high-voltage components locked within. Access needs special tools. Employee safety and security is a concern. The design includes stress relief devices. These secure versus interior faults. The unit features raising hooks. These streamline installation and handling. Connections are made by means of bushings. These bushings come under secured covers.
The transformer fulfills strict sector standards. These include IEEE and ANSI specs. It ensures trusted, lasting solution. Performance is dependable under normal operating conditions. It handles normal overloads as defined. Maintenance requirements are low. Routine inspections are recommended. These devices are a typical option for utility and private power circulation requirements. They deliver power efficiently and securely.
Applications of 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer
Pad-mounted transformers manage voltage step-down securely. They tip down higher circulation voltages to usable degrees. These units are common in many setups. They are built hard for exterior usage. They sit on concrete pads. This maintains them safe and secure and available. Usual voltages include 13.8 kV, 13.2 kV, and 12.47 kV. Requirement dimensions are 250KVA, 300KVA, 400KVA, 630KVA, and 750KVA. These ratings fit diverse power needs.
Residential areas make use of these transformers commonly. They power entire communities. They serve apartment complexes. They provide collections of residences. A 250KVA or 300KVA device may power a tiny subdivision. Larger complexes require 400KVA or 630KVA models. The transformer feeds the local grid. It gives secure voltage for homes.
Commercial buildings rely upon pad-mounted transformers too. They power shopping mall. They run office complex. They sustain colleges and medical facilities. A 400KVA or 630KVA transformer matches a tool shopping center. A huge workplace complicated could utilize a 750KVA system. These transformers manage substantial lots dependably. They make sure organization procedures run efficiently.
Industrial websites require robust power options. Factories utilize pad-mounted transformers. Storage facilities utilize them. Manufacturing plants rely on them. They power hefty equipment. They support complex processes. A 630KVA or 750KVA transformer deals with demanding industrial loads. It offers stable power for production lines. Safety and security is vital right here. The pad install style secures workers.
Utility business mount these systems widely. They put them along streets. They install them near brand-new growths. They upgrade older devices with them. The pad install layout saves area. It gets rid of the requirement for substation buildings. Maintenance crews access them easily. The systems are developed for lengthy life span. They stand up to weather condition extremes. They provide reliable power conversion daily. Selecting the appropriate voltage and KVA is vital. It matches the particular site demands perfectly.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of 13.8kv 13.2kv 12.47kv Three-phase 250KVA 300KVA Pad Installation Transformer 400KVA 630KVA 750KVA Pad Mounted Transformer
What exactly does this pad-mounted transformer do? It steps down higher voltage electricity from utility lines to safer, usable levels. This happens at properties needing reliable power. Common applications include commercial buildings, industrial facilities, and housing developments. It handles the power demands for lighting, equipment, and machinery.
What voltages does it work with? Our units accept common distribution voltages like 13.8kV, 13.2kV, and 12.47kV on the primary side. The secondary side typically outputs 480V or 208Y/120V. This flexibility suits various utility grid requirements. You need to specify the exact voltages when ordering.
Is it safe around people? Yes, safety is a major design focus. The transformer is completely enclosed in a sturdy, tamper-resistant steel tank. This tank is securely locked. It prevents accidental contact with live parts inside. The unit is built for outdoor installation. It withstands weather and protects the public.
How do you install it? Installation requires a solid concrete pad. This pad provides a stable, level foundation. The transformer sits directly on this pad. Qualified electrical crews handle the placement and wiring. They connect the high-voltage lines from the utility. They connect the lower voltage lines to your building. Proper grounding is absolutely essential. This ensures safety and correct operation.
What maintenance is needed? Pad-mounted transformers are designed for low maintenance. They are filled with dielectric fluid for cooling and insulation. Owners should schedule periodic visual inspections. Check for leaks, damage, or corrosion. Listen for unusual noises like excessive humming. Monitor the fluid level if possible. Report any problems immediately. Major servicing requires trained professionals.
REQUEST A QUOTE
RELATED PRODUCTS
 
High Efficiency 11kv Pad Mounted Substation Transformer, Resin Cast Three Phase Power Transformer
 
High Quality 25 Kva 75kva 100kva 167kva 12470v 7620v to 208/120v 120v with Three/Single Phase Pad Mounted Transformer
 
500kVA 15kV ANSI/IEEE Standards Loop Feed Radial Feed Pad Mounted Transformer
 
Purchase 3-ph 112.5kVA 150 KVA 225 KVA Three Phase Pad Mounted Transformer
 
3 Phase Outdoor Combined Box-type Substation 1600kva 8 Mva Pad Mounted Transformer Outdoor Substation 2000kva
 