40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of Low Voltage Transformers

40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor is critical power equipment that uses the axiom of electromagnetic induction to convert AC voltage, including voltage, current, impedance conversion, isolation, and stability functions. It usually consists of three parts: primary coil, secondary coil, and iron core (or magnetic core). Low-voltage transformers are widely used in power systems for voltage regulation, impedance matching, and safety isolation. It is also commonly used in various electronic devices and circuits, such as audio devices, TV receivers, computer power supplies, etc., to achieve functions such as voltage, current, and impedance conversion. In addition, low-voltage transformers also play an essential role in safety, preventing excessive recent or circuit failures from posing a threat to equipment or personal safety and protecting equipment from harmful effects such as sudden power changes and surge currnts.

Features of Low Voltage Transformers

Small size, low power, easy installation, suitable for low-power equipment and short distance power transmission.

Not using oil as an insulation medium is more environmentally friendly.

Has excellent moisture and corrosion resistance, suitable for harsh working environments.

Strong isolation, with high safety and reliability.

No need for oil inspection, filling, and replacement, reducing maintenance costs and workload.

Low magnetization current, low noise, low temperature rise, stable performance and high efficiency.

Specification of 40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor

This 40kVar Low Voltage Three-Phase Series Filter Reactor is a core power quality component. It works with transformers and capacitor banks. Its main job is controlling electrical current flow. It filters out harmful harmonic distortions. This cleaning action protects your sensitive equipment. Better power quality results.

The unit handles 40 kiloVolt-Amps Reactive (kVar) power. It’s built for standard low voltage systems. Expect voltages like 400V, 480V, or 690V. Frequency is usually 50Hz or 60Hz. It manages significant electrical currents safely.

Construction is robust. A high-grade iron core forms the base. Precision-wound copper coils surround this core. Special insulation materials ensure safety and long life. This design minimizes energy losses. Heat generation is kept low. The reactor stays cool during operation. Overheating risks are reduced.

Electrical performance is reliable. The inductance value is carefully set. This value is crucial for effective harmonic filtering. Low resistance windings are standard. Power loss is minimized. High thermal class insulation is used. The reactor withstands tough conditions. Voltage withstand levels meet strict safety rules. Impulse voltage tests are passed.

Mounting options are flexible. Vertical or horizontal installation is possible. Common terminal types are provided. Connection is straightforward. The enclosure protects internal parts. Dust and moisture resistance is good. Airflow is maintained for cooling.

This reactor is vital for capacitor banks. It limits inrush currents during switching. Capacitor damage is prevented. Resonance issues are avoided. System stability improves. Power factor correction works better. Efficiency increases across your network.

Harmonic filtering is a key strength. It targets specific troublesome harmonic orders. Common problems like 5th or 7th harmonics are suppressed. Voltage distortion drops. Your equipment runs smoother. Premature failures decrease. Maintenance costs go down.

Built-in thermal protection is often included. This guards against overloads. Long-term reliability is enhanced. Manufacturing follows international standards. IEC and UL guidelines are typical. Quality checks are thorough. Every unit is tested before shipping.

Applications of 40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor

This 40kVar Low Voltage Three-Phase Series Filter Reactor is essential equipment. It works with capacitor banks in power systems. Its main job is improving power quality. Harmonics are a big problem today. Harmonics come from modern devices. Devices like VFDs, UPS systems, and computers create harmonics. Harmonics cause issues. They lead to overheating in transformers and cables. They trip circuit breakers unnecessarily. They damage sensitive electronics. This reactor solves harmonic problems. It connects in series with capacitors. Together they form a tuned filter circuit. This filter targets specific harmonic frequencies. It traps these harmful harmonics. It prevents them from flowing back into the main power supply. Cleaner power results. System reliability increases significantly.

Power factor correction is another key application. Capacitors alone improve power factor. But capacitors can cause problems too. They might resonate with system inductance. Resonance creates voltage distortion. It amplifies existing harmonics. This reactor prevents resonance. It adds necessary impedance to the capacitor circuit. It shifts the resonance frequency away from harmonic frequencies. Safe and effective power factor correction happens. Power bills decrease. System capacity improves.

Voltage stability benefits too. This reactor helps control voltage rise. Capacitor banks can cause voltage rise at light loads. The reactor counters this effect. It limits capacitor inrush currents. It protects capacitors from damage during switching. This extends capacitor lifespan. It reduces maintenance costs.

Protection is vital. The reactor shields capacitors from high-frequency currents. These currents stress capacitor elements. Premature failure happens. The reactor absorbs these currents. It acts as a buffer. Transformer protection is also important. Harmonics increase transformer losses. They cause excessive heating. The filter reactor reduces harmonic currents flowing through transformers. Transformer operating temperature stays lower. Transformer life expectancy increases.

This equipment is crucial for industrial facilities. Data centers use it. Manufacturing plants need it. Any site using non-linear loads requires harmonic filtering. It ensures smooth operation. It protects valuable assets. It saves energy and money.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality 40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of 40kVar Low Voltage Three-Phase Series Filter Reactor /Transformer &Capacitors Reactor

What does this reactor do?
It cleans up electrical power. It stops bad electrical waves called harmonics. Harmonics damage equipment and waste energy. This reactor works with capacitors. It makes capacitors work better and last longer.

Where do I install it?
Put it directly in line with your capacitor bank. Connect it between the power source and the capacitors. This setup creates a filter circuit. The filter blocks specific harmonic frequencies.

Why is sizing important?
The reactor size must match your capacitor bank exactly. We use a 40kVar reactor for a 40kVar capacitor bank. Wrong sizing causes problems. Too big or too small reduces filtering. It can even damage the capacitors or the reactor itself.

How does it protect the capacitors?
Harmonics make capacitors overheat and fail early. The reactor blocks these harmful waves. It stops most harmonics from reaching the capacitors. This reduces stress and heat. Capacitors last much longer.

Does it need maintenance?
Check it visually sometimes. Look for signs of overheating, like discolored paint. Listen for loud humming noises. Ensure the connections stay tight. Clean dust off the cooling vents. Otherwise, it usually runs reliably for years.

REQUEST A QUOTE

REQUEST A QUOTE