Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection is an enclosed, ground-level electrical distribution transformer commonly used in underground (UG) power systems. It steps down primary high-voltage electricity (e.g., 15kV or 25kV) to a lower secondary voltage (e.g., 120/240V or 480V) for safe distribution to residential neighborhoods, commercial buildings, and industrial parks. Its robust, lockable steel enclosure makes it safe for public areas.

Features of Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

Ground-Level Enclosure: A locked, tamper-resistant, weatherproof steel cabinet that protects the internal components and ensures public safety.

Underground Cable Connections: Designed for easy connection to underground primary (high-voltage) and secondary (low-voltage) cables via compartments with built-in bushings.

Compartmentalization: Separate, isolated compartments for high-voltage and low-voltage components, enhancing safety during maintenance.

Ventilation: Designed with louvers or other ventilation systems to allow for proper heat dissipation from the transformer core and coils.

Lifting Lugs: Integrated lifting lugs for easy and safe installation and replacement using a crane or hoist.

Tamper-proof Hardware: Lockable doors with special bolts to prevent unauthorized access.

Fused Switches: Often includes fused disconnect switches for circuit protection and safe isolation.

Pad Foundation: Installed on a concrete pad (“pad-mounted”) to provide a stable, level base.

Specifications of Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

This custom transformer setup powers big electrical furnaces. It steps down high voltage electrical energy for commercial use. Input comes in at 69,000 volts. Result supplies a secure 208 volts. Everything installs safely on a concrete pad outside. This conserves area inside your center.

The unit includes an integrated circuit breaker. This breaker secures against electrical faults. It stops harmful overloads swiftly. An unique mechanical interlock is key. This lock physically stops errors during maintenance. You can closed the breaker compartment unless the power is totally off. This maintains workers secure from unintentional shocks.

The entire system is built difficult. It manages harsh industrial atmospheres well. Assume dust, vibration, temperature swings. Safety is the leading priority. The layout meets strict sector requirements. You get trustworthy power day and night. Downtime prices money, this tools lessens it.

Modification alternatives are available. Suit the transformer precisely to your heater tons. Readjust defense settings for your certain process. Select unit attributes for your neighborhood weather. The pad-mount style streamlines installment. No need for a different building.

Applications of Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

This devices deals with large power jobs. Manufacturing facilities need trusted high voltage power. This transformer takes 69,000 volts from the grid. It steps down this power to much safer, functional degrees. The result is 208 volts. This reduced voltage runs hefty machinery properly. The whole device rests safely on a pad exterior. This pad-mounted style saves important interior room.

Customization is essential. Various electrical heating systems have distinct power needs. This transformer adapts to fulfill those certain demands. You pick the exact voltage and power rating called for. This makes sure top heater performance. It prevents squandered energy. It shields your furnace financial investment.

Safety is integrated. The circuit breaker stops power flow instantaneously throughout issues. This protects people and tools. The mechanical interlock includes another safety and security layer. It physically stops risky procedures. You can not open the breaker area while real-time. You can not shut the breaker unless whatever is properly protected. This protects against harmful errors.

This configuration is essential for commercial electric heating systems. These furnaces melt metal or process products. They need secure, high-power power. The transformer delivers this reliably. The breaker and interlock warranty safe operation. Workers stay shielded. Equipment stays clear of damages from electric mistakes. The pad-mounted layout maintains the system obtainable outdoors. Upkeep is simpler. space continues to be free.

Steel foundries utilize this system. Steel recycling plants rely upon it. Any center making use of huge electrical arc or induction furnaces benefits. It supplies the regulated power they demand. The safety features are non-negotiable for high-risk areas. This transformer package uses a reliable solution. It powers crucial commercial processes securely and efficiently.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of Customizable Electric Furnace Transformer 69KV Input 208V Pad-Mounted Substation Circuit Breaker Mechanical Interlock Protection

This transformer steps down high voltage for industrial furnaces. It takes 69,000 volts input. It gives 208 volts output. The whole unit sits in a pad-mounted enclosure. The circuit breaker inside has a mechanical interlock. This prevents dangerous mistakes. Here are common questions:

What parts can we customize? You choose the power rating. Match it to your furnace needs. Pick the exact input voltage taps. Select the output voltage taps. Decide on the enclosure size. Choose the circuit breaker type. Specify protective devices. Tell us your wiring configuration.

Why is 69kV input and 208V output important? 69kV is common for bringing power long distances. It saves money. Stepping it down to 208V is standard for big industrial motors. It powers large furnace equipment safely. This setup fits typical factory power grids.

How does the mechanical interlock protect workers? The interlock physically blocks the breaker. You cannot close it while the enclosure door is open. This stops accidental contact with live parts. It prevents the breaker from closing onto a fault. It is a vital safety barrier during maintenance. It keeps people safe.

Where does this pad-mounted unit get installed? Place it on a concrete pad outside your facility. Put it near the furnace load. This minimizes voltage drop. It connects directly to the utility’s 69kV line. It feeds the 208V power straight to your furnace controls. The pad mount protects it from weather and accidents.

What maintenance does the transformer and breaker need? Check oil levels and condition regularly. Inspect bushings and connections yearly. Test the circuit breaker operation often. Verify the mechanical interlock works every time you access it. Keep the enclosure clean and secure. Follow the manufacturer’s specific schedule.

REQUEST A QUOTE

REQUEST A QUOTE