High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer is precision instruments designed for accurate measurement and reliable protection in high-voltage electrical systems. They safely step down high primary currents to standardized, low-level secondary outputs, enabling safe monitoring, metering, and control by connected devices. Essential for power transmission, distribution, and industrial applications, our transformers ensure system safety, efficiency, and stability.

Features of High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

High Accuracy Class: Precision-engineered for dependable measurement in metering and protection circuits.

Robust Insulation: Advanced insulation materials (e.g., epoxy resin, oil-impregnated) ensure long-term reliability and safety under high dielectric stress.

Wide Current Range: Available in various ratios to accommodate diverse application requirements.

Low Power Loss: Optimized core design for minimal energy loss, enhancing overall system efficiency.

Excellent Linearity: Superior performance across a wide range of operating conditions.

Durable Construction: Built to withstand harsh environmental conditions, including moisture, pollution, and temperature fluctuations.

Specification of High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

This High-Tension Indoor Current Transformer handles demanding electrical measurement tasks. It works safely inside buildings. The unit steps down high currents to safer, lower levels. This allows accurate monitoring and protection. Two common ratios are available: 100/5 and 200/5. These ratios suit different load requirements. The 100/5 model handles up to 100 amps primary current. The 200/5 model manages up to 200 amps. Both provide a standardized 5-amp secondary output. This output connects easily to meters and relays.

The transformer is built for single-phase systems. It accepts input voltages reaching 10kV. This high-voltage capability is essential for industrial power networks. Robust insulation materials surround the core and windings. This prevents electrical breakdown. The design prioritizes safety for indoor installations. The enclosure resists dust and moisture. It ensures long-term reliability.

Accuracy matters greatly. This current transformer delivers precise measurements. It meets strict class standards. Performance stays consistent under varying loads. The copper windings minimize energy loss. The high-grade core material reduces errors. Connections are clearly marked. Installation is straightforward for electricians.

This unit integrates into switchgear panels. It monitors power usage in factories. It protects equipment from overloads. Common applications include energy metering and circuit protection. The transformer isolates measurement devices from dangerous high voltage. This protects both instruments and personnel. Minimal maintenance is needed. It offers a dependable solution for high-voltage current sensing.

Applications of High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

This High-Tension Indoor Current Transformer handles tough jobs inside buildings. It works with 10kV high voltage systems. You get two common CT ratios: 100/5 and 200/5. This means it safely steps down high current levels for measurement and protection devices.

Its main job is measuring electricity flow accurately. You connect it to meters or energy management systems. It gives precise readings of how much power equipment uses. This is vital for billing customers correctly. It also helps track energy efficiency.

Protecting equipment is its other critical role. The transformer connects to protective relays. These relays monitor for problems like overloads or short circuits. The CT provides the relay with a scaled-down, safe current signal. This lets the relay detect faults fast. It can then trip breakers to prevent damage.

This CT is built for indoor use. It withstands the electrical stresses of 10kV systems. Its design ensures reliable operation near other high-voltage gear. The transformer is robust. It handles demanding industrial environments well. You find it in factories, commercial buildings, and substations.

It fits into switchgear panels and control cabinets easily. Its single-phase input suits many common applications. You don’t need complex installation. Technicians find it straightforward to wire into existing systems. Maintenance is minimal due to its solid construction.

Applications are widespread. Use it for metering electricity usage in large facilities. It feeds data to SCADA systems for real-time monitoring. It’s essential for protecting motors, generators, and transformers from electrical faults. Power quality analyzers use its signal to check voltage and current stability.

Company Profile

PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.

It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer, please send us inquiries; we will be here to help you.


Payment Methods

L/C, T/T, Western Union, Paypal, Credit Card etc.


Shipment

By sea, by air, by express, as customers request.


Storage Conditions

1) Store in a dry environment at room temperature.

2) Avoid damp and high temperature.

3) Use immediately after opening the inner packing bag.

5 FAQs of High-Tension Indoor Current Transformer CT 100/5 200/5 Single-Phase Input Voltage 10kv High Voltage Transformer

What does this transformer do?
It measures high-voltage electricity safely. It steps down dangerous 10kV currents to much lower levels like 5 amps. Meters or protective devices use this safer signal. It protects equipment and gives accurate readings without direct high-voltage contact.

Where should I install it?
Install it only indoors. It’s built for dry, protected environments like switchgear panels or substation buildings. Never place it outdoors. Outdoor conditions like rain or extreme temperatures damage it. Ensure proper spacing around it for airflow and safety access.

What are the 100/5 and 200/5 ratios?
These are its measurement scales. The 100/5 ratio means when 100 amps flow through the main line, the transformer outputs 5 amps. The 200/5 ratio means 200 amps input gives 5 amps output. You pick the ratio matching your expected current flow for accurate metering.

What wires connect to it?
Connect the high-voltage power line (10kV) to its primary terminals. These terminals handle the full dangerous voltage. Connect the secondary terminals to your meter or relay. These output the safe, low 5A signal. Always follow the wiring diagram exactly. Wrong connections break the device or give false readings.

How do I maintain it?
Keep it clean and dry. Dust buildup can cause overheating. Check connections stay tight. Loose wires cause bad readings or heat. Look for cracks or damage on the case. Never open it yourself. Have a qualified technician test its accuracy and insulation strength periodically.

REQUEST A QUOTE

REQUEST A QUOTE