أنا. Product Overview

The 110kV oil-immersed power transformer is a core piece of equipment in power transmission and distribution systems. It is primarily used to transform high voltage of 110 كيلو فولت (كيلو فولت) to lower voltage levels such as 35kV or 10kV, or vice-versa, enabling economical, efficient transmission and distribution of electrical energy. Renowned for its high reliability, سعة كبيرة, عمر خدمة طويل, and mature manufacturing technology, it plays an indispensable role in national grids, regional networks, and large-scale industrial projects.

Product Model Example: SFSZ11-50000/110

  • س: ثلاث مراحل
  • ف: Air-Cooled
  • س: Three-Winding
  • Z: On-Load Tap Changer
  • 11: Design Series Number (Performance level code, على سبيل المثال, يكتب 11 indicates low-loss, energy-efficient products)
  • 50000: القدرة المقدرة (كيلو فولت أمبير)
  • 110: Rated Voltage Level on High-Voltage Side (كيلو فولت)

II. Main Structure

The transformer is mainly composed of the following major parts:

1. Core and Windings (Core Component)

  • جوهر: Made from high-grade, high-permeability, cold-rolled grain-oriented silicon steel laminations, stacked using a stepped-lap (multi-step lap) process. Its function is to form the magnetic circuit, offering excellent magnetic permeability and low no-load loss.
  • اللفات: Comprise the high-voltage winding, medium-voltage winding (if applicable), and low-voltage winding. Typically constructed using interleaved, continuous disc, or helical types, wound from oxygen-free copper conductors, and subjected to rigorous insulation treatment. The windings form the electrical circuit of the transformer.

2. Tank and Cooling System

  • Tank: Welded from steel plates, it houses the core with windings and the transformer oil, and provides mechanical support and external protection. The tank walls are fitted with cooling fins or removable radiators.
  • زيت المحولات: Uses high-quality mineral oil or synthetic ester insulating oil. Main functions: Insulation, Cooling, و Arc Quenching (within the on-load tap-changer).
  • Cooling Equipment: Depending on capacity, primarily uses زيت طبيعي هواء طبيعي (أونان) أو Oil Forced Air Forced (أوفاف) cooling. Fans force air over the radiators to accelerate oil cooling.

3. نظام الحماية

  • الحافظ (Oil Expension Tank): Compensates for the expansion and contraction of the transformer oil due to temperature changes, reduces contact between oil and air, and delays oil aging. Often equipped with a diaphragm (bag or bellows) for full sealing.
  • Breather (Dehydrating Breather): Contains silica gel desiccant to absorb moisture from the air entering the conservator, keeping the oil dry.
  • تتابع بوخهولز (تتابع الغاز): Installed in the pipe between the main tank and the conservator. It activates an alarm or trips the circuit breaker in case of minor internal faults generating gas or sudden, violent oil surges.
  • Pressure Relief Device: Rapidly opens to relieve internal pressure in case of a serious fault, preventing tank rupture.
  • Sudden Pressure Relay (خياري): Provides further protection by limiting pressure rise due to internal arcing faults.
  • مؤشر درجة الحرارة: Monitors the top oil temperature, providing remote signals and local reading.

4. البطانات

  • High-Voltage Bushing: Safely brings the high-voltage leads from the internal windings out through the tank. The 110kV level typically uses oil-impregnated paper capacitor bushings, which offer excellent electric field grading and insulation performance.
  • Medium/Low-Voltage Bushings: Bring out the leads from the medium and low-voltage windings.

5. اضغط على المغير

  • Off-Circuit Tap Changer (DETC): Allows tap position changes only when the transformer is disconnected from the network.
  • On-Load Tap Changer (OLTC): Automatically or manually changes tap positions while the transformer is energized and under load, to stabilize the output voltage. This is a key component in modern smart grids.

III. مبدأ العمل

Based on the principle ofالحث الكهرومغناطيسي. When an AC voltage is applied to the primary (الجهد العالي) لف, it creates an alternating magnetic flux in the core. This alternating flux links with the secondary (الجهد المنخفض) لف, inducing an electromotive force (EMF) in it. The voltage ratio is equal to the turns ratio:U1U2=N1N2ش2​ش1​​=N2​N1​​

By changing the number of turns in the winding (i.e., operating the tap changer), voltage transformation is achieved.

IV. Key Features & المزايا

  • موثوقية عالية: Mature construction, stable materials, comprehensive protection systems, design life typically exceeds 30 سنين.
  • High Efficiency & Energy Saving: Utilizes low-loss silicon steel and advanced design, resulting in low no-load and load losses, compliant with national energy efficiency standards (على سبيل المثال, غيغابايت 20052).
  • أداء عزل ممتاز: The oil-paper insulation system formed by transformer oil and insulating paper possesses very high dielectric strength.
  • Superior Heat Dissipation: The circulating flow of oil effectively carries away heat generated by the core and windings.
  • Easy Maintenance: Equipped with various monitoring and protection devices, facilitating condition monitoring and regular maintenance.
  • Strong Adaptability: Can be configured with on-load tap changers, enhanced cooling systems, إلخ., to suit different load demands and operating environments.

V. Main Technical Parameters

Parameter CategoryTypical DescriptionRemarks
الجهد المقننHV Side: 110±8×1.25% / 121 كيلو فولتIndicates tap range and rated voltage
MV Side (if applicable): 38.5 كيلو فولت
LV Side: 10.5 / 11 كيلو فولت
القدرة المقدرة10,000 kVA ~ 150,000 كيلو فولت أمبيرCommon capacity ratings
التردد المقدر50 هرتزChinese Standard
مجموعة المتجهاتYNyn0d11 or YNd11Common for three-winding or two-winding
Impedance VoltageApprox. 10.5% ~ 18%Depends on capacity and design
No-Load LossMeets or exceeds GB 20052 معيارعلى سبيل المثال, يكتب 11 < 15 كيلوواط (for 50MVA)
Load LossMeets or exceeds GB 20052 معيارعلى سبيل المثال, يكتب 11 < 220 كيلوواط (for 50MVA)
Sound Level 65 ديسيبل(أ)Measured at 0.3 meters from the equipment
Cooling Methodأونان / أوفاف
Tap Changer TypeOff-Circuit or On-Load
Insulation LevelLI480 AC200 / LI325 AC140 / LI75 AC35HV/MV/LV Lightning Impulse/Power Frequency Withstand Voltage

VI. Application Fields

  • Regional Substations: Acts as a hub between transmission and distribution grids, stepping down 110kV to 10kV or 35kV.
  • Large Industrial Plants: Such as steel, petrochemical, مراكز البيانات, serving as the core equipment in the main step-down substation.
  • Power Plants: Serves as a generator step-up transformer, elevating the generator output voltage to 110kV for grid connection.
  • Urban Power Grid Construction & Renovation: Meets the growing power demand in urban load centers.

VII. Transportation, تثبيت & صيانة

Perform periodic inspection and oil replacement for the on-load tap changer.

Transportation: Must be transported under a positive pressure of nitrogen or dry air, strictly preventing moisture ingress. Strict limits apply to the tilt angle during transport.

تثبيت: Must be performed by specialized personnel: positioning on foundation, oil filling, settling, vacuum pumping, hot oil cycling, إلخ., to ensure restoration of insulation performance.

Routine Maintenance:

Regularly check oil level, oil temperature, and breather silica gel color.

Periodically take oil samples for testing (chromatography, moisture content, dielectric strength – دي جي ايه). This is an effective method for diagnosing incipient internal faults.

Conduct regular electrical tests (winding resistance, مقاومة العزل, turns ratio, إلخ.).