Overview of Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase
En olie-nedsænket transformer er en type elektrisk transformer, hvor kernen og viklingerne er nedsænket i en isolerende olie. Denne olie tjener to primære funktioner: det fungerer som en yderst effektiv isolator mellem ledende dele og som et kølemiddel til at sprede varme genereret under drift. Disse transformere er robuste, pålidelig, og yderst effektiv, hvilket gør dem til standardvalget for højspændingsstrømdistributions- og transmissionsnetværk, typisk installeret udendørs i transformerstationer.
Features of Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase
- Effektiv køling: Den isolerende olie absorberer effektivt varme fra kernen og viklingerne og overfører den til radiatorfinnerne, giver mulighed for naturlig eller tvungen cirkulation og højere overbelastningskapacitet.
- Overlegen isolering: Olien giver meget bedre dielektrisk styrke end luft, giver mulighed for et mere kompakt design for en given spændingsværdi og beskytter mod kortslutninger.
- Robust konstruktion: Designet til langsigtet, pålidelig drift (ofte 25-30 år) i barske udendørsmiljøer.
- Overbelastningskapacitet: Kan håndtere midlertidige strømoverbelastninger bedre end transformatorer af tør type på grund af oliens termiske masse og køleegenskaber.
- Beskyttelsessystem: Udstyret med konservatortank (for at give mulighed for olieudvidelse), åndedræt (at absorbere fugt fra luften), og beskyttelsesrelæer (Buchholz stafet) til intern fejlsøgning.
- Omkostningseffektiv: Generelt mere økonomisk til højeffektapplikationer sammenlignet med transformatorer af tør type.
Specifications of Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase
This transformer handles single-phase power at 50Hz. It comes in two common sizes: 50kVA og 100kVA. The rated power output matches these kVA figures. The primary voltage accepts standard inputs like 11kV or 33kV. The secondary voltage provides common outputs such as 415V or 230V. Voltage taps allow adjustment, typically ±5%. This helps maintain stable output under varying input conditions.
Kernen bruger højkvalitets kornorienteret siliciumstål. This material minimizes energy loss. Copper or aluminum forms the windings. Copper offers better conductivity. Aluminum provides a cost-effective option. Both materials ensure efficient power transfer. The entire active assembly sits inside a robust steel tank. This tank is filled with high-quality insulating mineral oil. The oil insulates the components. It also cools the transformer effectively.
Varme opbygges under drift. Olien optager denne varme. Natural oil circulation moves the heated oil. Olien flyder rundt om kernen og viklingerne. The heat transfers to the tank walls. The surrounding air cools the tank surface. This process is called ONAN cooling. It stands for Oil Natural, Naturlig luft. Larger units might need radiators. Radiators increase the cooling surface area.
The transformer includes essential protection. A silica gel breather prevents moisture entry. A pressure relief device vents excess pressure quickly. En oliestandsmåler viser oliemængden. A drain valve allows oil sampling or removal. An earthing terminal provides a safe ground connection. These features protect the transformer. They ensure reliable, langsigtet drift.
Strenge test bekræfter ydeevne. Every unit undergoes standard factory tests. These tests include resistance measurements. They check voltage ratio and polarity. They confirm no-load and load losses. Impedance voltage is also measured. Dielectric tests verify insulation strength. Additional tests like temperature rise may be performed. These tests guarantee the transformer meets specifications. The transformer complies with IEC standards. It adheres to relevant national regulations.
Applications of Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase
Single phase oil filled transformers work well where three phase power isn’t needed or available. These 50Hz models use oil for cooling and insulation. The 50kVA and 100kVA sizes are common for many smaller power jobs. They are tough and reliable for everyday use.
People often need these transformers in houses or small buildings far from main power lines. They boost the voltage safely for homes. This keeps lights on and appliances running smoothly. Farms use them too. They power equipment like water pumps and small machines. The oil inside helps handle outdoor weather.
Telephone companies and internet providers use these transformers. They power remote signal boxes and cell phone towers. The oil keeps things cool even during heavy use. Small factories and workshops also rely on them. They run tools, lys, and other essential gear. The 50kVA size is good for medium loads. The 100kVA handles bigger demands.
Construction sites need portable power. These oil filled transformers are built for that. They power temporary lighting and tools. They are simple to move and set up. Solar power and wind energy projects often use them too. They connect small renewable systems safely to the local grid. The oil insulation makes them safe and long-lasting.
Shops and small businesses find them useful. They provide stable power for cash registers, computere, and lighting. The 50kVA model suits many shops well. The 100kVA supports larger stores or small manufacturing units. They are a practical choice for reliable power where high capacity isn’t necessary. Their simple design makes maintenance easier.
Virksomhedsprofil
PDDN Photoelectron Technology Co., Ltd. er en af de førende virksomheder inden for kraftelektronikteknologi og kraftprodukter, som er fuldt involveret i at udvikle solcelle-invertere, transformere, spændingsregulatorer, fordelingsskabe, tyristorer, moduler, dioder, varmelegemer, og andre elektroniske enheder eller halvledere. Vi vil være forpligtet til at give brugerne høj kvalitet, effektive produkter og hensynsfuld service.
Det accepterer betaling med kreditkort, T/T, Vestunionen, og Paypal. PDDN vil sende varerne til kunder i udlandet gennem FedEx, DHL, til søs, eller med fly. If you want high-quality Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase, send os venligst forespørgsler; vi vil være her for at hjælpe dig.
Betalingsmetoder
L/C, T/T, Western Union, Paypal, Kreditkort osv.
Forsendelse
Ved havet, med fly, ved ekspres, som kunder efterspørger.
Opbevaringsbetingelser
1) Opbevares i et tørt miljø ved stuetemperatur.
2) Undgå fugt og høj temperatur.
3) Bruges umiddelbart efter åbning af den indvendige pakkepose.
5 FAQs of Single Phase Oil Filled Transformer 50Hz Oil Immersed Transformer 50kVA Oil Filled Transformer 100kVA Single Phase
Her er 5 common questions about our 50Hz Single Phase Oil Filled Transformers (50kVA & 100kVA models):
What exactly is a single phase oil filled transformer?
Det er en elektrisk enhed. It changes voltage levels for single phase power systems. The core and windings sit inside a tank filled with insulating oil. This oil cools the transformer and provides electrical insulation. Our models handle 50kVA or 100kVA power at 50Hz frequency.
Hvorfor bruge olie inde i transformeren?
Olien er afgørende. Det absorberer varme, der genereres under drift. This keeps the transformer from overheating. The oil also acts as a powerful electrical insulator. It prevents short circuits inside the tank. Denne kombination sikrer stabil ydeevne og lang levetid.
What do the 50Hz and kVA ratings mean?
50Hz is the standard electrical frequency used in many countries. The transformer is built specifically for this frequency. The kVA rating (like 50kVA or 100kVA) shows its power handling capacity. A 50kVA unit handles less power than a 100kVA unit. Choose the size matching your actual load requirements.
Hvor skal jeg installere denne transformer?
Place it outdoors or in a well-ventilated indoor area. The oil tank needs space for heat dissipation. Ensure the location is dry and protected from direct weather exposure if possible. Good airflow around the transformer is important. Follow local electrical codes and safety regulations precisely.
Er disse transformere sikre?
Ja, sikkerhed er en prioritet. The tank is sealed to prevent oil leaks. We use high-quality mineral oil with good insulating properties. The design includes features for safe operation under normal conditions. Always operate the transformer within its rated voltage and power limits. This prevents overloads and potential hazards. Regular maintenance checks are essential for ongoing safety.
ANMOD ET TILBUD
RELATEREDE PRODUKTER

Pålidelig 110kV oliefyldt træktransformator til elektrisk skinne

10.5kV 22kV 35kV Indgang 1000-7000kVA Trefaset tør-type transformer Lavstøj Elektrisk til ensrettersystem

Three Phase 30-2500Kva 6-11Kv 400-440Kv 50Hz 60Hz Transformer Oil Immersed Power Transf Oil Immersed Transformer

JLSW3-10 Udendørs olie-nedsænket kombineret transformer, måletank

400kva 500 Kva 4000kva Trefaset Step Down Transformer 11kv til 400v 415v Polmonteret distributionstransformer