Leverandør af elektroniske komponenter | Transformere, Induktorer, Invertere
PRODUKTPARAMETRE
Beskrivelse
Overview of Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer
Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer is an enclosed, jordnær elektrisk distributionstransformator, der almindeligvis anvendes i undergrunden (og) strømsystemer. Det nedtrapper primær højspændingselektricitet (f.eks., 15kV eller 25 kV) til en lavere sekundær spænding (f.eks., 120/240V eller 480V) for sikker distribution til boligkvarterer, erhvervsbygninger, og industriparker. Den er robust, aflåseligt stålkabinet gør det sikkert til offentlige områder.
Features of Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer
Indkapsling i jordniveau: A låst, manipulationssikret, vejrbestandigt stålskab, der beskytter de indvendige komponenter og sikrer offentlig sikkerhed.
Underjordiske kabelforbindelser: Designet til nem forbindelse til underjordisk primær (højspænding) og sekundær (lavspænding) kabler via rum med indbyggede bøsninger.
Opdeling: Adskille, isolerede rum til højspændings- og lavspændingskomponenter, øge sikkerheden under vedligeholdelse.
Ventilation: Designet med lameller eller andre ventilationssystemer for at tillade korrekt varmeafledning fra transformatorkernen og spolerne.
Løfteluger: Integrerede løfteøjer for nem og sikker montering og udskiftning med kran eller hejs.
Indgrebssikker hardware: Låsbare døre med specielle bolte for at forhindre uautoriseret adgang.
Fuserede afbrydere: Indeholder ofte sikrede afbryderkontakter til kredsløbsbeskyttelse og sikker isolering.
Pad Foundation: Installeret på en betonpude (“pudemonteret”) at give en stald, niveau base.
Specifications of Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer
This personalized 50kVA distribution transformer provides dependable power. It’s built for single-phase applications. The conventional frequency is 60Hz. It adheres to IEEE criteria for pad-mounted installments. This suggests it’s created for outside use. It rests securely on a concrete pad. You choose the winding material. Light weight aluminum windings use a cost-effective option. Copper windings give higher conductivity. Both alternatives meet performance demands.
Transformeren tager sig af 50 kilovolt-ampere. This is its power capacity. Key voltage rankings are adaptable. Usual choices include 12470Y/7200V or 7620/13200Y volts. Additional voltage is normally 120/240 volt. This fits standard property and light business requirements. Details voltages are custom-configured. Tell us your specific requirements.
Effectiveness is essential. The style decreases energy losses. This saves operating costs in time. The transformer uses mineral oil for insulation and air conditioning. Beholderen er af robust stål. It safeguards the inner components. It withstands extreme weather conditions. The transformer includes pressure alleviation gadgets. These boost security throughout mistakes.
Discontinuations come. They are located under pad-mounted covers. This configuration protects against unintended call. It meets safety and security policies. Bushings link to the electrical system. They are created for underground cable links. Criterion accessories consist of lifting lugs. These make setup easier. Basing pads are common. They make certain proper system grounding.
This transformer meets IEEE C57.12.00 criteria. It likewise fulfills IEEE C57.12.20 requirements. These cover basic needs and pad-mounted specifics. Optional attributes are readily available. These consist of lightning arresters or protective gadgets. Temperature level evaluates monitor procedure. Unique paint coatings stand up to corrosion. Inform us concerning your website conditions. We tailor the transformer to fit.
Applications of Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer
This custom 50kVA 60Hz single-phase transformer fulfills rigorous IEEE requirements. It is developed for pad-mounted distribution. You select light weight aluminum or copper windings. This transformer efficiently steps down high voltage for local power shipment. It feeds homes, virksomheder, or little commercial sites needing single-phase power.
Its pad-mounted layout maintains it secure and safe. The system remains on a concrete pad outdoors. This shields it from weather and unapproved accessibility. The locked steel room protects against meddling. It is tough sufficient for severe atmospheres. The compact dimension conserves beneficial room.
Personalization is essential. We tailor the design to your specific voltage demands. We match certain primary and second voltages. This guarantees smooth assimilation right into your existing grid. Options include different taps, bøsninger, and devices. We build it to manage your distinct tons needs.
Product option issues. Aluminum windings offer an economical remedy. They provide reliable efficiency for typical applications. Copper windings deliver greater effectiveness. They handle overloads much better and last longer. Both choices ensure exceptional conductivity and longevity.
This transformer focuses on safety and integrity. It fulfills all IEEE safety regulations. Advanced insulation systems stop failings. The robust building and construction reduces upkeep requirements. It provides stable power even under heavy use. Power losses are kept reduced to conserve operating expense.
Installationen er ligetil. The pad-mounted design gets rid of the need for poles. Connection factors are easily obtainable. Specialists can service it rapidly. Dette reducerer nedetiden. It is a trustworthy link in your power distribution chain.
Virksomhedsprofil
PDDN Photoelectron Technology Co., Ltd. er en af de førende virksomheder inden for kraftelektronikteknologi og kraftprodukter, som er fuldt involveret i at udvikle solcelle-invertere, transformere, spændingsregulatorer, fordelingsskabe, tyristorer, moduler, dioder, varmelegemer, og andre elektroniske enheder eller halvledere. Vi vil være forpligtet til at give brugerne høj kvalitet, effektive produkter og hensynsfuld service.
Det accepterer betaling med kreditkort, T/T, Vestunionen, og Paypal. PDDN vil sende varerne til kunder i udlandet gennem FedEx, DHL, til søs, eller med fly. If you want high-quality Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer, send os venligst forespørgsler; vi vil være her for at hjælpe dig.
Betalingsmetoder
L/C, T/T, Western Union, Paypal, Kreditkort osv.
Forsendelse
Ved havet, med fly, ved ekspres, som kunder efterspørger.
Opbevaringsbetingelser
1) Opbevares i et tørt miljø ved stuetemperatur.
2) Undgå fugt og høj temperatur.
3) Bruges umiddelbart efter åbning af den indvendige pakkepose.
5 FAQs of Custom 50kVA 60Hz IEEE Pad Mounted Distribution Transformer Aluminum or Copper Single Phase Transformer
Hvad gør denne transformer?
This custom 50kVA transformer changes electricity voltage. It steps down higher voltage to lower voltage usable by homes or businesses nearby. It’s built for single-phase power systems running at 60Hz. It sits inside a sturdy pad-mounted enclosure meeting IEEE standards.
Hvad er de vigtigste specifikationer?
The transformer handles 50,000 volt-ampere (50kVA). Det virker kl 60 Hertz frequency. You can choose primary and secondary voltage ratings based on your specific power grid needs. The enclosure is weatherproof and tamper-resistant. It’s designed for safe outdoor installation on a concrete pad.
Can I get special features?
Ja. This transformer is custom-built. You select either aluminum or copper windings. You specify the exact input and output voltages required. Options include different types of cooling fluid, special bushings, or extra protection devices. The enclosure finish and color can also match your site.
What’s the difference between aluminum and copper?
Aluminiumsviklinger koster mindre. They are lighter weight. Copper windings are more efficient. They lose less power as heat. Copper handles overloads slightly better. Copper transformers are physically smaller for the same power rating. Your choice depends on budget and long-term efficiency goals.
Hvordan er det installeret?
Installation needs trained utility workers. Transformatoren kommer færdigmonteret. Workers place it on a prepared concrete pad. They connect the high-voltage cables and low-voltage cables through the enclosure’s bushings. They ground the tank properly. After testing, the unit is ready for service.
ANMOD ET TILBUD
RELATEREDE PRODUKTER

Høj kvalitet A220525 enfaset pad-monteret transformer til tank OEM ODM lavet i Vietnam

10kv 1000kva Strømforsyning Pad monteret transformer Industrielle elektriske transformere Kompakt boks Type understation

250kVA 500kVA 750kVA 1000kVA 1250kVA 1500kVA 2000kVA 2500kVA 2750kVA 3000kVA 3750kVA 3 Trefaset padmonteret transformer

350-2500kVA 35kv110kv Elektronisk 3-faset Power Oil Nedsænket Transformer 480v Pad Monteret Distribution MV&HV transformere

1000KVA10kv 13,8kv 33kv Pad-monteret transformer understation Trefaset ZGS11 Udendørs brug 380V/400V/690V



