7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

PARÁMETROS DEL PRODUCTO

Descripción
SOLICITAR COTIZACIÓN

Descripción

Overview of 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer is an enclosed, Transformador de distribución eléctrica a nivel del suelo comúnmente utilizado en el subsuelo. (y) sistemas de energía. Reduce la electricidad primaria de alto voltaje (p.ej., 15kV o 25kV) a un voltaje secundario más bajo (p.ej., 120/240V o 480V) para una distribución segura en barrios residenciales, edificios comerciales, y parques industriales. Es robusto, El recinto de acero con cerradura lo hace seguro para áreas públicas.

Features of 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

Cerramiento a nivel del suelo: un cerrado, resistente a manipulaciones, Gabinete de acero resistente a la intemperie que protege los componentes internos y garantiza la seguridad pública..

Conexiones de cables subterráneos: Diseñado para una fácil conexión a la primaria subterránea (de alta tensión) y secundaria (bajo voltaje) cables a través de compartimentos con pasatapas incorporados.

Compartimentación: Separado, Compartimentos aislados para componentes de alto y bajo voltaje., mejorar la seguridad durante el mantenimiento.

Ventilación: Diseñado con rejillas u otros sistemas de ventilación para permitir una disipación de calor adecuada desde el núcleo del transformador y las bobinas..

Orejas de elevación: Orejas de elevación integradas para una instalación y sustitución fáciles y seguras mediante una grúa o un polipasto.

Hardware a prueba de manipulaciones: Puertas con cerradura con pernos especiales para evitar el acceso no autorizado..

Interruptores fusionados: A menudo incluye interruptores de desconexión con fusibles para protección del circuito y aislamiento seguro..

Base de almohadilla: Instalado sobre una plataforma de concreto. (“montado en plataforma”) para proporcionar un establo, base de nivel.

Specifications of 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

Here’s the item web content for those transformers:

This schedule covers crucial single-phase pad-mounted transformers for numerous demands. These systems step down greater voltages to usable levels for equipment or centers. They are constructed challenging for outside installments. Placing straight on concrete pads is typical. This gets rid of posts or platforms. All models include effective electrical steel cores. These cores minimize energy loss during operation. Natural air cooling keeps things straightforward. No se necesitan ventiladores ni bombas.. Weatherproof enclosures shield interior parts. They hold up against rainfall, nieve, suciedad, and common outdoor conditions. Security is incorporated. Units consist of stress alleviation devices and basing points. Upkeep gain access to is simple. Links are plainly marked.

El 7.97 kV/50kVA model handles main voltage near 8kV. It supplies 50kVA additional power. This matches moderate power requirements. El 13.8 kV/75kVA unit approves a higher key voltage. It provides 75kVA output capacity. This fits larger loads needing even more power. El 14.4 kV/100kVA transformer takes care of the greatest primary voltage provided. It supplies a considerable 100kVA. This supports significant electrical demands. Each unit matches its specific input voltage and output ability.

Likewise available is a smaller 5kVA step-down transformer. It complies with the exact same durable pad-mounted style concepts. This compact unit is perfect for reduced power applications. It tips down voltage dependably for smaller sized equipment requirements. All transformers are created for reputable, long-lasting service. They satisfy common sector demands.

Applications of 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

These transformers step down high voltage power. They make it secure for day-to-day usage. El 7.97 kV 50kVA device takes care of smaller sized loads. El 13.8 kV 75kVA version offers more capability. El 14.4 kV 100kVA transformer sustains bigger demands. All are single-phase layouts. They work well where three-phase power isn’t offered.

Their main work is reducing voltage. They take power from utility lines. They provide it at safer, niveles utilizables. This is crucial for homes and local business. They connect directly to the distribution grid. They offer trustworthy neighborhood power conversion.

These pad-mounted transformers prevail views. You see them on concrete pads near structures. This positioning keeps them protected and obtainable. It shields them from weather condition and vandalism. The unit is robust and tamper-resistant. El mantenimiento es sencillo. Professionals can service them easily.

They are excellent for houses. They power groups of houses successfully. They serve remote ranches and rural properties well. They support tiny commercial buildings reliably. Think shops, oficinas, or centers. They power equipment needing lower voltage. This includes illumination, dispositivos, y equipo.

Sturdiness is a crucial feature. They hold up against rough outside problems. Lluvia, nieve, calor, and cool don’t influence efficiency. They are developed for long-lasting operation. They provide regular voltage law. Esto protege los dispositivos sensibles aguas abajo.

Room effectiveness is another benefit. Their pad-mounted style conserves room. No need for big substation structures. They incorporate neatly right into existing landscapes. They use a functional remedy. They bring high-voltage power securely to the factor of usage. They are vital for modern electric distribution. They guarantee power gets to customers reliably.

Perfil de la empresa

PDDN Photoelectron Technology Co., Limitado. es una de las empresas líderes en tecnología de electrónica de potencia y productos de energía., que participa plenamente en el desarrollo de inversores solares, transformadores, reguladores de voltaje, gabinetes de distribución, tiristores, módulos, diodos, calentadores, y otros dispositivos electrónicos o semiconductores. Nos comprometeremos a proporcionar a los usuarios alta calidad., Productos eficientes y servicio considerado..

Acepta pago mediante Tarjeta de Crédito, T/T, Unión Oeste, y paypal. PDDN enviará los productos a clientes en el extranjero a través de FedEx, DHL, por mar, o por aire. If you want high-quality 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer, por favor envíenos sus consultas; estaremos aquí para ayudarte.


Métodos de pago

carta de crédito, T/T, Western Union, PayPal, Tarjeta de crédito, etc..


Envío

Por mar, en avión, por expreso, como los clientes lo solicitan.


Condiciones de almacenamiento

1) Almacenar en un ambiente seco a temperatura ambiente..

2) Evite la humedad y las altas temperaturas..

3) Úselo inmediatamente después de abrir la bolsa de embalaje interior..

5 FAQs of 7.97kv50kva 13.8kv75kva 14.4kv100kva Single Phase 5kva Step Down Transformer Pad Mounted Transformer

People often ask about our single phase pad mounted transformers. Here are five common questions. What exactly do these transformers do? They take high voltage electricity from utility lines. They step it down to safer levels for homes and businesses. We offer models handling 7.97kV/50kVA, 13.8kV/75kVA, and 14.4kV/100kVA inputs. Each outputs a lower 5kVA voltage suitable for end-use.

¿Dónde se instalan normalmente estos transformadores?? You see them near buildings needing power. They sit on concrete pads at ground level. This makes them easy to access for maintenance. They work well for houses, pequeñas tiendas, or farm buildings. They connect directly to overhead or underground utility lines.

¿Son seguros estos transformadores?? Sí, la seguridad es una prioridad. The metal enclosure protects the internal components. It keeps people out and weather away. La carcasa es resistente a manipulaciones y se puede cerrar con llave.. Esto evita el contacto accidental con partes vivas.. It also deters vandalism.

¿Qué se necesita para la instalación?? Necesitas un sólido, plataforma de concreto nivelada. The size depends on the specific transformer model. Proper grounding is absolutely critical. It must follow local electrical codes exactly. Enough clearance space around the unit is necessary for air flow and service access. A qualified electrician must handle the wiring connections.

Do they require much maintenance? Pad mounted transformers are generally low-maintenance. Se recomiendan inspecciones visuales periódicas.. Check for damage, leaks, o corrosión. Listen for unusual noises like humming. Keep the area around the transformer clear of debris and vegetation. Professional testing might be needed periodically.

SOLICITAR COTIZACIÓN

SOLICITAR COTIZACIÓN