Alimentation en boucle triphasée électrique standard ANSI 1000kva 1500kva 2000kva sous-station de transformateur de puissance triphasée montée sur tampon

PARAMÈTRES DU PRODUIT

Description
DEMANDER UN DEVIS

Description

Overview of ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation

ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation is an enclosed, transformateur de distribution électrique au niveau du sol couramment utilisé dans le sous-sol (et) systèmes électriques. Il réduit l'électricité primaire à haute tension (par ex., 15kV ou 25kV) à une tension secondaire inférieure (par ex., 120/240V ou 480V) pour une distribution sécurisée dans les quartiers résidentiels, bâtiments commerciaux, et parcs industriels. C'est robuste, le boîtier en acier verrouillable le rend sécuritaire pour les espaces publics.

Features of ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation

Enceinte au niveau du sol: Un verrouillé, inviolable, armoire en acier résistante aux intempéries qui protège les composants internes et assure la sécurité publique.

Connexions de câbles souterrains: Conçu pour un raccordement facile au primaire souterrain (haute tension) et secondaire (basse tension) câbles via compartiments avec traversées intégrées.

Compartimentation: Séparé, compartiments isolés pour composants haute tension et basse tension, améliorer la sécurité pendant la maintenance.

Ventilation: Conçu avec des persiennes ou d'autres systèmes de ventilation pour permettre une bonne dissipation de la chaleur du noyau et des bobines du transformateur.

Oreilles de levage: Œillets de levage intégrés pour une installation et un remplacement faciles et sûrs à l'aide d'une grue ou d'un palan.

Matériel inviolable: Portes verrouillables avec boulons spéciaux pour empêcher tout accès non autorisé.

Commutateurs à fusibles: Comprend souvent des sectionneurs à fusible pour la protection des circuits et une isolation sûre.

Fondation de tampon: Installé sur une dalle de béton (“sur socle”) pour fournir une stabilité, base de niveau.

Specifications of ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation

This ANSI conventional pad-mounted transformer substation provides reputable three-phase power for requiring applications. It comes in 1000kVA, 1500kVA, and 2000kVA scores. The loophole feed design is key. It permits power to flow in multiple directions. This offers adaptability. It additionally boosts reliability. Si une ressource cesse de fonctionner, power commonly proceeds from another direction.

The system is built tough. Its unit is tamper-proof and weather-resistant. It satisfies NEMA 3R standards. This shields versus rainfall, neige, et la poussière. The steel building and construction is durable. It has corrosion-resistant coatings. This ensures lengthy life outdoors. The pad-mounted configuration indicates it rests straight on a concrete base. This saves room. It removes the need for a separate structure.

À l'intérieur, high-efficiency core and coil settings up reduce energy loss. The transformer utilizes mineral oil for cooling and insulation. It has ample air conditioning fins or radiators. These dissipate warmth properly. This maintains the unit running cool. It manages heavy tons safely. Typical voltage rankings follow common utility demands. Primary voltages like 12470Y/7200V or 13800Y/7970V are normal. Additional voltages are often 480Y/277V or 208Y/120V. Various other configurations are available.

La sécurité est importante. It includes stress relief devices. It has noticeable fault indicators. Raising factors are standard for very easy installation and upkeep. Access panels are safe and secure. They require special tools. This stops unauthorized entrance. The design focuses on functional safety for energy crews and the public.

These substations power huge facilities reliably. They are excellent for shopping mall. They sustain industrial facilities. They serve big household areas. They back up vital infrastructure. They handle the significant electrical lots these areas demand. The loophole feed capacity uses a substantial reliability benefit over simpler radial feed styles. The pad-mounted form aspect integrates well into established areas. It offers utility-grade power distribution where area is restricted. Its durable building withstands harsh ecological problems every year.

Applications of ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation

ANSI conventional electric pad placed 3 stage power transformers are crucial equipment. They deal with the 1000kva, 1500kva, and 2000kva dimensions. These devices are built hard for demanding work. Their loophole feed design is a significant advantage. It enables power to move from two instructions. This keeps power running also if one line falls short. That indicates fewer outages for everyone attached.

These transformers function completely in congested city communities. Below ground power lines are common there. The pad place design rests safely on a concrete slab. It maintains whatever safe and unseen. This saves important space above ground. Industrial parks require reliable power as well. Factories utilize lots of electrical energy for big equipments. The 1000kva to 2000kva range fits lots of factory needs. The loop feed setup secures assembly line. A single power failing won’t quit working.

Shopping mall and office buildings benefit greatly. They require consistent power for lights, systèmes informatiques, and a/c. These transformers supply that power effectively. They tip down high voltage securely. The power comes to be useful for shops and workplaces. New housing growths likewise utilize them. They supply the foundation power for whole neighborhoods. The ANSI common guarantees safety and security and integrity. Whatever satisfies strict sector regulations.

Renewable resource projects use these transformers. Solar farms and wind setups create power. This power frequently feeds into the grid. Pad placed transformers make the link possible. They take care of the power transfer smoothly. Utilities trust them for vital places. They require devices that helps years without trouble. The robust construction takes care of weather extremes. Chaleur, froid, précipitations, or snow won’t quit them. Upkeep is additionally simpler. Service technicians gain access to components conveniently for checks and solutions.

Profil de l'entreprise

PDDN Photoélectronique Technology Co., Ltée. est l'une des principales entreprises dans le domaine de la technologie électronique de puissance et des produits électriques, qui est pleinement impliqué dans le développement des onduleurs solaires, transformateurs, régulateurs de tension, armoires de distribution, thyristors, modules, diodes, radiateurs, et autres appareils électroniques ou semi-conducteurs. Nous nous engagerons à fournir aux utilisateurs des produits de haute qualité, produits efficaces et service attentionné.

Il accepte les paiements par carte de crédit, T/T, Union occidentale, et Paypal. PDDN expédiera les marchandises aux clients à l'étranger via FedEx, DHL, par la mer, ou par avion. If you want high-quality ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation, veuillez nous envoyer des demandes; nous serons là pour vous aider.


Méthodes de paiement

L/C, T/T, Western union, Paypal, Carte de crédit, etc..


Expédition

Par la mer, par avion, par express, comme le demandent les clients.


Conditions de stockage

1) Conserver dans un environnement sec à température ambiante.

2) Évitez l'humidité et les températures élevées.

3) Utiliser immédiatement après avoir ouvert le sac d'emballage intérieur.

5 FAQs of ANSI Standard Electric 1000kva Three Phase Loop Feed 1500kva 2000kva Pad Mounted Three Phase Power Transformer Substation

This transformer substation is a pad-mounted unit. It meets ANSI standards. Il gère l'alimentation triphasée. Available sizes are 1000kVA, 1500kVA, et 2000kVA. It uses a loop feed design. This design allows power to flow in a loop. It improves reliability for neighborhoods or businesses. Voici les questions courantes que les gens posent.

A quoi sert exactement ce transformateur? This unit steps down high voltage electricity. It brings it to a safer, niveau utilisable. It feeds power underground to multiple buildings nearby. You see it in housing developments, centres commerciaux, ou parcs industriels. It connects to the main grid.

Where can we install this pad-mounted substation? Il repose sur une dalle de béton à l'extérieur. It needs space for air flow and safety clearances. You place it at ground level. It works well in areas needing underground power. It avoids overhead lines. It fits urban and suburban spots.

Quelles caractéristiques de sécurité inclut-il? La sécurité est essentielle. Le boîtier en acier est inviolable et verrouillé. It shields live parts. It meets strict ANSI safety rules. It protects against electrical faults. It keeps the public safe near the equipment.

A-t-il besoin d'un entretien particulier? These units are built for low upkeep. Ils sont très fiables. Technicians check them periodically. Ils recherchent des fuites, dommage, ou signes de surchauffe. They test the oil and connections. This keeps it running smoothly for years.

Combien de temps prend l'installation? Installation time varies. It depends on site prep and utility coordination. The pad must be poured and cured first. Then the unit is placed and connected. Underground cable work takes time too. Plan several weeks typically. The utility company manages the schedule.

DEMANDER UN DEVIS

DEMANDER UN DEVIS