Ola Trí Chéim tumtha 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

Paraiméadair TÁIRGÍ

Cur síos
IARRATAS A CHUID

Cur síos

Overview of Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

Is cineál claochladán leictreach é claochladán ola-tumtha ina bhfuil an croí agus na foirceannadh báite in ola inslithe. Feidhmíonn an ola seo dhá phríomhfheidhm: feidhmíonn sé mar inslitheoir an-éifeachtach idir páirteanna seoltacha agus mar chuisnithe chun teas a ghintear le linn oibriú a scaipeadh. Tá na claochladáin seo láidir, iontaofa, agus an-éifeachtach, rud a fhágann gurb iad an rogha chaighdeánach iad maidir le líonraí dáileacháin agus tarchurtha cumhachta ardvoltais, suiteáiltear lasmuigh go hiondúil i bhfostáisiúin.

Features of Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

  • Fuarú Éifeachtach: Déanann an ola inslithe teas a ionsú go héifeachtach ón gcroí agus ón bhfoirceannadh agus aistrítear chuig eití an radaitheora é, ag ligean do chúrsaíocht nádúrtha nó iachall agus cumas ró-ualaithe níos airde.
  • Insliú Superior: Soláthraíonn an ola neart tréleictreach i bhfad níos fearr ná aer, ag ligean do dhearadh níos dlúithe do rátáil voltais ar leith agus ag cosaint in aghaidh gearrchiorcaid.
  • Tógáil Láidir: Deartha le haghaidh fadtéarmach, oibriú iontaofa (go minic 25-30 blianta) i dtimpeallachtaí crua amuigh faoin aer.
  • Cumas Overload: Is féidir leis ró-ualaí cumhachta sealadacha a láimhseáil níos fearr ná claochladáin de chineál tirim mar gheall ar mhais theirmeach agus airíonna fuaraithe an ola.
  • Córas Cosanta: Feistithe le umar coimeádaithe (chun leathnú ola a cheadú), análóir (chun taise ón aer a ionsú), agus athsheachadáin chosanta (sealaíochta Buchholz) chun locht inmheánach a bhrath.
  • Costas-Éifeachtach: Go ginearálta níos eacnamaí d'iarratais ardchumhachta i gcomparáid le claochladáin de chineál tirim.

Specifications of Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

This transformer handles heavy industrial power demands. Tá sé rangaithe do 4000 KVA or 4 MVA. This indicates it handles big electric lots reliably. The three-phase design fits manufacturing facilities and huge facilities.

It utilizes oil for insulation and air conditioning. The oil circulates normally around the core and windings. This maintains temperatures safe during procedure. The air conditioning type is ONAN (Ola Aer Nádúrtha Nádúrtha). This is simple and trustworthy.

Úsáideann an croí cruach sileacain den scoth. This lowers power losses significantly. The windings are copper for reliable power transfer. They are very carefully scheduled stability. The entire assembly rests inside a solid, welded steel tank. This storage tank holds the protecting oil safely.

Common voltage ratings prevail. Main might be 11kV, 15kV, 22kV, nó 33kV. Secondary could be 0.415 kV, 3.3 kV, 6.6 kV, nó 11kV. Tá voltais eile indéanta. Resistance is normally around 6%, but it can be adjusted. This regulates fault currents efficiently.

Power losses are an essential emphasis. The layout lessens no-load loss and tons loss. This conserves cash over the transformer’s long life. Insulation course is generally Class A. The BIL (Basic Impulse Level) ard. This shields against voltage rises.

Ritheann an claochladán go ciúin. Sound levels are maintained low. Temperature level surge is limited. It stays well below safety margins. The tank consists of functions for easy upkeep. There’s an oil conservator, a rest, and a Buchholz relay. The relay identifies inner faults swiftly.

Extensive testing guarantees top quality. Each system passes regular checks. Type examinations and special examinations are also executed. Requirements like IEC 60076 or IEEE C57.12.00 are adhered to. This guarantees security and efficiency.

Applications of Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

3 phase oil submersed 4000 KVA (4 MVA) power transformers deal with big electrical loads accurately. They are vital devices where substantial power distribution or voltage change is needed. Utilities use these transformers thoroughly. They step down high transmission voltages to much safer, reduced levels for neighborhood distribution networks feeding communities, páirceanna tionscail, or large business complexes. This makes certain power reaches end-users efficiently and safely.

Industries depend on these durable transformers. Áiseanna déantúsaíochta, plandaí ceimiceacha, mianaigh, and huge manufacturing centers need steady, cumhacht ard-acmhainn. Tá an 4000 KVA system supplies the necessary change point within their interior electric systems. It powers hefty equipment, huge electric motors, and substantial handling lines without disturbance. Oil immersion successfully cools the transformer windings and core during continual durable procedure.

Renewable energy tasks also utilize these transformers. Solar farms and wind installments create power, usually at tool voltage levels. Tá an 4000 KVA transformer boosts this voltage for efficient transmission over longer ranges to the primary grid connection factor. This reduces power losses during transportation.

Huge facilities jobs require trustworthy power circulation. Críochfoirt aerfoirt, poirt, ionaid sláinte, university schools, and significant information facilities all have considerable electricity needs. These transformers develop vital nodes within their dedicated electric circulation grids, making certain constant power circulation to vital systems and structures. They are frequently set up in substations on-site.

Their robust oil-immersed layout makes them ideal for requiring environments. They offer excellent security against overloads and supply steady operation over extended periods. This reliability is vital for mission-critical procedures. They likewise function as crucial parts in backup power systems for necessary centers.

Próifíl na Cuideachta

PDDN Photoelectron Technology Co., Teo. ar cheann de na fiontair tosaigh i dteicneolaíocht leictreonaic cumhachta agus táirgí cumhachta, a bhfuil baint iomlán aige le forbairt inverters gréine, trasfhoirmeoirí, rialtóirí voltais, caibinéid dáileacháin, thyristors, modúil, dé-óid, téitheoirí, agus gléasanna leictreonacha nó leathsheoltóirí eile. Beimid tiomanta d'ardchaighdeán a sholáthar d'úsáideoirí, táirgí éifeachtacha agus seirbhís tuisceanach.

Glacann sé le híocaíocht trí Chárta Creidmheasa, T/T, Aontas Iarthar, agus Paypal. Seolfaidh PDDN na hearraí chuig custaiméirí thar lear trí FedEx, DHL, cois farraige, nó d'aer. If you want high-quality Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta, seol fiosrúcháin chugainn le do thoil; beidh muid anseo chun cabhrú leat.


Modhanna Íocaíochta

L/C, T/T, Aontas Iarthar, Paypal, Cárta Creidmheasa etc.


Loingsiú

Ar muir, ag aer, trí chur in iúl, mar a iarrann custaiméirí.


Coinníollacha Stórála

1) Stóráil i dtimpeallacht thirim ag teocht an tseomra.

2) Seachain taise agus teocht ard.

3) Bain úsáid as díreach tar éis an mála pacála istigh a oscailt.

5 FAQs of Three Phase Oil Immersed 4000 KVA 4 MVA Trasfhoirmeoir Cumhachta

Cad a dhéanann an claochladán seo??
seo 4000 KVA oil-filled transformer handles large amounts of electricity. Céimeann sé voltas suas nó síos. This is vital for efficient power transmission over long distances or supplying factories.

Cén fáth go bhfuil sé líonta le hola?
Feidhmíonn an ola ar dhá phríomhphost. It cools the transformer’s core and windings during operation. The oil also acts as a powerful electrical insulator. This prevents dangerous short circuits inside the unit.

Cá háit a n-úsáidtear an claochladán seo de ghnáth?
You find this transformer in demanding industrial settings. Large factories, major mining operations, and big infrastructure projects need its high capacity. Utility substations also use it within power distribution grids.

How safe is the oil inside?
The oil is highly refined mineral oil. It’s stable and non-explosive under normal conditions. The transformer tank is welded steel. It is built strong to contain the oil safely. Pressure relief devices protect against extreme internal faults.

Cén chothabháil a theastaíonn?
Tá seiceálacha rialta riachtanach. Technicians monitor oil levels and test oil quality for breakdown. They inspect bushings, ceangail, and cooling radiators. External cleaning keeps surfaces free from dirt. Internal inspections require specialized service.

IARRATAS A CHUID

IARRATAS A CHUID