Luoyang Datang Energyphotoelectron. The company deals in the R&D, déantúsaíocht, and sales of various medium, high, and Voltage Transformers and Transformer Accessories. The transformer accessories mainly include Buchholz Relay, Tap Changer, oil level gauge, Butterfly Valve, Moisture Absorber, pressure reducing valve, Cross Flow Cooling Fan, Bimetal Thermometer, Epoxy Resin Insulator, srl. New and old customers are welcome to purchase and customize.
The basic structure of oil level gauge
The Pointer Oil Level Gauge (from now on referred to as the oil level gauge) applies to the oil level display of the Oil Immersed Transformer oil conservator and on-load tap changer oil conservator as well as the alarm of the lowest and highest limit oil level.
The oil level gauge is mainly composed of the display part composed of a pointer and dial, the alarm part consisting of the magnet (or cam) and switch, and the transmission part consisting of a reversing and variable speed gear set, swing rod, and float ball.
Installation of oil-level juice
An oil-level gauge with a floating ball-shaped swing rod should be installed in the center of the end cover of the oil conservator, and the swing rod should swing radially. Other oil level gauges with floating ball-type swing rods should be installed at the lowest oil level in the oil conservator. The telescopic rod-type oil level gauge for the diaphragm oil conservator shall be installed at the highest oil level of the oil conservator. During the installation of the oil level gauge, it must be ensured that the movable space of the swing rod and the floating ball is not interfered with by any structure.
Inspection before installation of oil level gauge
Before installation, check whether the oil level gauge is damaged and rusted during storage and transportation, and install it after treatment.
Before installing the oil level gauge, gently and slowly pull the swing rod to rotate flexibly and reliably and signal at the extreme position.
Before installing the oil level gauge, check whether the lead cable, outlet terminal, and signal switch are well insulated.
Maintenance of oil level gauge
The oil level gauge shall be checked once a year during operation. Check whether the lead wire and switch are well insulated and whether the sealing gasket needs to be replaced.
Luoyang Datang Energyphotoelectron. The company deals in the R&D, déantúsaíocht, and sales of various medium, high, and Voltage Transformers and Transformer Accessories. The transformer accessories mainly include Buchholz Relay, Tap Changer, oil level gauge, Butterfly Valve, Moisture Absorber, pressure reducing valve, Cross Flow Cooling Fan, Bimetal Thermometer, Epoxy Resin Insulator, srl. New and old customers are welcome to purchase and customize.
The basic structure of oil level gauge
The Pointer Oil Level Gauge (from now on referred to as the oil level gauge) applies to the oil level display of the Oil Immersed Transformer oil conservator and on-load tap changer oil conservator as well as the alarm of the lowest and highest limit oil level.
The oil level gauge is mainly composed of the display part composed of a pointer and dial, the alarm part consisting of the magnet (or cam) and switch, and the transmission part consisting of a reversing and variable speed gear set, swing rod, and float ball.
Installation of oil-level juice
An oil-level gauge with a floating ball-shaped swing rod should be installed in the center of the end cover of the oil conservator, and the swing rod should swing radially. Other oil level gauges with floating ball-type swing rods should be installed at the lowest oil level in the oil conservator. The telescopic rod-type oil level gauge for the diaphragm oil conservator shall be installed at the highest oil level of the oil conservator. During the installation of the oil level gauge, it must be ensured that the movable space of the swing rod and the floating ball is not interfered with by any structure.
Inspection before installation of oil level gauge
Before installation, check whether the oil level gauge is damaged and rusted during storage and transportation, and install it after treatment.
Before installing the oil level gauge, gently and slowly pull the swing rod to rotate flexibly and reliably and signal at the extreme position.
Before installing the oil level gauge, check whether the lead cable, outlet terminal, and signal switch are well insulated.
Maintenance of oil level gauge
The oil level gauge shall be checked once a year during operation. Check whether the lead wire and switch are well insulated and whether the sealing gasket needs to be replaced.
Forbhreathnú CuideachtaLuoyang Datang Energyphotoelectron is a manufacturer of various high and low voltage power supporting products.
Transformer accessories include tap changer, pressure relief valve, thermometer, moisture absorber, gas relay, oil level gauge, butterfly valve, cross flow fan, srl.
High-voltage power distribution equipment includes high-voltage and low-voltage insulation bushings, high-voltage cables, disconnectors, vacuum circuit breakers, high-voltage insulators, low-voltage insulation, ceramic insulators, srl
Ó bunaíodh é, tá an chuideachta i gcónaí faoi threoir na heolaíochta agus na teicneolaíochta, backed by strong technology, tugadh isteach go gníomhach teicneolaíocht chun cinn eachtrach, agus i gcónaí feabhsaithe agus feabhsaithe a chuid táirgí. Tar éis blianta de bhainistíocht ghairmiúil, the products sell well all over the country and are exported to Bangladesh, Myanmar, India, Russia, Indonesia, Thailand and other Southeast Asian and African countries.
Fáilte romhat cuairt a thabhairt, investigate and negotiate
Tréithe Táirge
Múnla Uimh.: YZF3-250
Branda: PDDN
Warranty Period: 3 Years
Certification: Csa, Pcoc, Reach, Iecee, Scoc, Ul, Epa, Gs, CE/CCC
Support Customization: Oem, Odm
Áit Tionscnaimh: tSín
Ainm Táirge: Pointer type oil level gauge
Cineál: YSF/YZS
Ambient Temperature: -40°C~+50°C
Texture Of Material: Metal
Temperature Range: <90%(at 20 ℃)
Applicable To Oil Tank Diameter: 800mm-1600mm
Installation Flange Opening: 80mm-130mm
Float Diameter: 80-125mm
Waterproof Performance: IP55
Pacáistiú & Seachadadh
| Aonaid PDDN-Díol | : | Piece/Pieces |
| PDDN-Single package size | : | 15cm*20cm*15cm |
| PDDN-Single gross weight | : | 1.8kg |
| Cineál Pacáiste | : | PDDN-Carton |
| Sampla Pictiúr | : |
|
IARRATAS A CHUID
TÁIRGÍ GAOLMHARA
Single phase to 3phase cross cooling flow fan China Manufacturer

Small Electrical Transformer 50kva 100kva 200kva Power Amplifier Transformer

Different Sizes of Punches Laminated Iron Core Transformer Iron Sheet Motor Accessories for Automotive Industry Application

Ferrite Core and Bobbin Horizontal/vertical Transformer Bobbin Plastic EE ETD PQ Transformer Accessories Bobbins

Transformer Pressure Gauge Release Valve Transformer Valve Pressure Relief Valve