10/11kV Industrial Oil Immersed Transformer for Electrical Substation

PARAMETER PRODUK

Keterangan
PERMINTAAN PENAWARAN

Keterangan

Overview of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Trafo terendam oli adalah jenis trafo listrik yang inti dan belitannya terendam dalam minyak isolasi.. Minyak ini memiliki dua fungsi utama: ia bertindak sebagai isolator yang sangat efektif antara bagian konduktif dan sebagai pendingin untuk menghilangkan panas yang dihasilkan selama pengoperasian. Transformator ini kuat, dapat diandalkan, dan sangat efisien, menjadikannya pilihan standar untuk jaringan distribusi dan transmisi tenaga listrik tegangan tinggi, biasanya dipasang di luar ruangan di gardu induk.

Features of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

  • Pendinginan yang Efektif: Oli isolasi secara efisien menyerap panas dari inti dan belitan serta memindahkannya ke sirip radiator, memungkinkan sirkulasi alami atau paksa dan kapasitas kelebihan beban yang lebih tinggi.
  • Isolasi Unggul: Minyak memberikan kekuatan dielektrik yang jauh lebih baik dibandingkan udara, memungkinkan desain yang lebih kompak untuk peringkat tegangan tertentu dan melindungi terhadap korsleting.
  • Konstruksi Kuat: Dirancang untuk jangka panjang, operasi yang andal (sering 25-30 bertahun-tahun) di lingkungan luar ruangan yang keras.
  • Kapasitas Kelebihan Beban: Dapat menangani kelebihan daya sementara dengan lebih baik daripada transformator tipe kering karena massa termal dan sifat pendinginan oli.
  • Sistem Proteksi: Dilengkapi dengan tangki konservator (untuk memungkinkan ekspansi minyak), istirahat (untuk menyerap kelembapan dari udara), dan relay pelindung (Relai Buchholz) untuk deteksi kesalahan internal.
  • Hemat Biaya: Umumnya lebih ekonomis untuk aplikasi daya tinggi dibandingkan trafo tipe kering.

Specifications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

This transformer powers industrial sites and substations. It steps down high voltage electricity. The main voltage ranking is 10kV or 11kV. The secondary voltage matches your specific devices demands. We construct it tough for demanding industrial settings.

The core utilizes state-of-the-art grain-oriented silicon steel. This lessens power loss during procedure. Copper windings guarantee reliable power transfer and resilience. The entire active assembly sits inside a durable steel storage tank. The storage tank is filled with high-grade insulating mineral oil.

The oil does 2 major tasks. It cools down the transformer properly. It likewise gives vital electric insulation inside. This style is known as Oil Natural Air Natural (ONAN). Heat climbs naturally via the oil. Then it dissipates from the container’s surface into the air. External radiators enhance the air conditioning surface area. This deals with higher loads securely.

Defense is essential. The tank consists of a conservator tank. The conservator holds additional oil. It enables oil expansion as temperature levels change. A rest with silica gel maintains moisture out of the oil. A Buchholz relay identifies interior faults. It causes an alarm or shuts the transformer down. Stress alleviation devices prevent dangerous container overpressure. These attributes secure the transformer and your employees.

We build according to rigorous international criteria. Usual standards include IEC 60076 or IEEE C57.12.00. Every device undergoes rigorous manufacturing facility testing. This consists of ratio checks, winding resistance tests, and insulation resistance checks. We perform induced voltage examinations and used voltage examinations. We measure tons loss and no-load loss exactly. Temperature increase examinations confirm cooling efficiency. Impulse examinations confirm strength versus voltage rises. This screening guarantees safety and security and integrity. You get a transformer prepared for long-lasting solution.

Applications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Industrial oil-immersed transformers rated 10/11kV are essential tools for electrical substations. They take care of the essential task of voltage change. Substations get power at high transmission voltages. These transformers tip that voltage down to more secure, usable degrees like 10kV or 11kV. This stepped-down power is then dispersed successfully to factories, plants, and large facilities nearby.

Their durable oil-immersed style makes them excellent for requiring industrial setups. The shielding oil inside serves 2 vital objectives. It cools down the transformer windings successfully during continual hefty procedure. It also offers excellent electric insulation, preventing harmful brief circuits. This dependability is important for substations sustaining essential commercial processes.

You locate these transformers directly inside devoted substation structures or safe outside rooms. They develop the core web link between the high-voltage grid and the regional industrial power network. Their primary feature is dispersing the stepped-down power reliably. They feed power straight to huge electric motors, hefty machinery, and substantial plant-wide electrical systems within manufacturing facilities, tambang, or handling plants.

These transformers are constructed hard. They deal with the consistent, heavy electrical loads typical in market. The oil cooling system takes care of the substantial warm generated. This makes sure steady procedure night and day. Their design focuses on long life and very little downtime. This is critical for commercial operations where unanticipated power loss suggests significant production stops and monetary loss. They offer the steady, reputable power foundation industrial facilities definitely need.

Profil Perusahaan

PDDN Fotoelektron Technology Co., Ltd. adalah salah satu perusahaan terkemuka di bidang teknologi elektronika daya dan produk daya, yang terlibat penuh dalam pengembangan inverter surya, transformator, pengatur tegangan, lemari distribusi, thyristor, modul, dioda, pemanas, dan perangkat elektronik atau semikonduktor lainnya. Kami akan berkomitmen untuk menyediakan layanan berkualitas tinggi kepada pengguna, produk yang efisien dan layanan penuh perhatian.

Ia menerima pembayaran melalui Kartu Kredit, T/T, Serikat Barat, dan Paypal. PDDN akan mengirimkan barang ke pelanggan di luar negeri melalui FedEx, DHL, melalui laut, atau melalui udara. If you want high-quality 10/11kV Industrial Oil Immersed Transformer for Electrical Substation, silakan kirimkan pertanyaan kepada kami; kami akan berada di sini untuk membantu Anda.


Metode Pembayaran

L/C, T/T, Serikat Barat, Paypal, Kartu Kredit dll.


Pengiriman

Melalui laut, melalui udara, dengan mengungkapkan, sebagai permintaan pelanggan.


Kondisi Penyimpanan

1) Simpan di lingkungan kering pada suhu kamar.

2) Hindari lembab dan suhu tinggi.

3) Gunakan segera setelah membuka kantong kemasan bagian dalam.

5 FAQs of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Here are five common questions about 10/11kV Industrial Oil Immersed Transformers for electrical substations:

What does this transformer do?
This transformer changes electricity’s voltage level. It steps down the high voltage electricity coming into the substation. It makes the voltage safe for factories or large buildings to use. It powers heavy machinery and equipment reliably.

Why use oil inside it?
The transformer core and windings sit inside special insulating oil. This oil does two main jobs. It cools the transformer parts during operation. It also provides vital electrical insulation. Oil cooling handles large power loads effectively. It keeps temperatures stable.

What are its main features?
These transformers are built tough for demanding industrial sites. They use strong steel tanks holding the oil and internal parts. Radiators or cooling fins attach to the tank. They help dissipate heat. Robust bushings safely bring the electrical cables in and out. Protective devices monitor oil levels and temperature. They give warnings if problems happen.

Is it safe?
Safety is a top priority. The transformer tank is completely sealed. This prevents oil leaks. Modern designs often include pressure relief devices. These protect the tank if internal pressure builds too high. Fire walls or special pits around the installation add extra safety. They contain any potential oil fire. Regular testing ensures it meets strict safety standards.

How much maintenance does it need?
Oil immersed transformers need regular professional checks. Technicians test the oil quality often. They look for moisture or chemical breakdown. They inspect the physical condition of the tank, bushings, and cooling surfaces. They check all connections are tight. They confirm protective devices work correctly. Keeping the transformer clean and dry is also important. Proper maintenance extends its working life significantly. It prevents unexpected failures.

PERMINTAAN PENAWARAN

PERMINTAAN PENAWARAN