10/11kV Industriell Ueleg Immersed Transformer fir elektresch Ënnerstatioun

PRODUIT PARAMETER

Beschreiwung
Ufro engem ZITAT

Beschreiwung

Overview of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

En Ueleg-Taucht Transformator ass eng Zort elektreschen Transformator wou de Kär an d'Wicklungen an engem isoléierende Ueleg ënnergeet sinn. Dësen Ueleg déngt zwou primär Funktiounen: et handelt als héich effektiven Isolator tëscht konduktiven Deeler an als Kältemëttel fir d'Hëtzt, déi während der Operatioun generéiert gëtt, ze dissipéieren. Dës Transformatoren si robust, zouverlässeg, an héich efficace, mécht se de Standardwahl fir Héichspannungsverdeelung an Iwwerdroungsnetzwierker, typesch dobaussen an Ënnerstatiounen installéiert.

Features of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

  • Effektiv Ofkillung: Den Isoléierueleg absorbéiert effizient Hëtzt aus dem Kär an de Wicklungen an iwwerdréit et op d'Heizkierperfinnen, erlaabt natierlech oder gezwongen Zirkulatioun a méi héich Iwwerlaaschtkapazitéit.
  • Superior Isolatioun: Den Ueleg bitt vill besser dielektresch Kraaft wéi Loft, erlaabt fir e méi kompakt Design fir eng bestëmmte Volt Bewäertung a Schutz géint kuerz Circuit.
  • Robust Konstruktioun: Entworf fir laangfristeg, zouverlässeg Operatioun (oft 25-30 Joer) an haarden Outdoor Ëmfeld.
  • Iwwerlaascht Kapazitéit: Kann temporär Kraaft Iwwerlaascht besser handhaben wéi dréchent Transformatoren wéinst der thermescher Mass an der Ofkillungseigenschaften vum Ueleg.
  • Schutz System: Equipéiert mat engem Conservator Tank (Ueleg Expansioun ze erlaben), Otemschwieregkeeten (fir Feuchtigkeit aus der Loft ze absorbéieren), a Schutzrelais (Buchholz relais) fir intern Feeler Detektioun.
  • Käschten-effikass: Allgemeng méi ekonomesch fir Héichkraaftapplikatiounen am Verglach mat dréchent Transformatoren.

Specifications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

This transformer powers industrial sites and substations. Et trëfft Héichspannungsstroum erof. The main voltage ranking is 10kV or 11kV. The secondary voltage matches your specific devices demands. We construct it tough for demanding industrial settings.

The core utilizes state-of-the-art grain-oriented silicon steel. This lessens power loss during procedure. Copper windings guarantee reliable power transfer and resilience. The entire active assembly sits inside a durable steel storage tank. The storage tank is filled with high-grade insulating mineral oil.

The oil does 2 major tasks. It cools down the transformer properly. It likewise gives vital electric insulation inside. This style is known as Oil Natural Air Natural (ONAN). Heat climbs naturally via the oil. Then it dissipates from the container’s surface into the air. External radiators enhance the air conditioning surface area. This deals with higher loads securely.

Defense is essential. The tank consists of a conservator tank. The conservator holds additional oil. It enables oil expansion as temperature levels change. A rest with silica gel maintains moisture out of the oil. A Buchholz relay identifies interior faults. It causes an alarm or shuts the transformer down. Stress alleviation devices prevent dangerous container overpressure. These attributes secure the transformer and your employees.

We build according to rigorous international criteria. Usual standards include IEC 60076 oder IEEE C57.12.00. Every device undergoes rigorous manufacturing facility testing. This consists of ratio checks, winding resistance tests, and insulation resistance checks. We perform induced voltage examinations and used voltage examinations. We measure tons loss and no-load loss exactly. Temperature increase examinations confirm cooling efficiency. Impulse examinations confirm strength versus voltage rises. This screening guarantees safety and security and integrity. You get a transformer prepared for long-lasting solution.

Applications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Industrial oil-immersed transformers rated 10/11kV are essential tools for electrical substations. They take care of the essential task of voltage change. Substations get power at high transmission voltages. These transformers tip that voltage down to more secure, usable degrees like 10kV or 11kV. This stepped-down power is then dispersed successfully to factories, Planzen, and large facilities nearby.

Their durable oil-immersed style makes them excellent for requiring industrial setups. The shielding oil inside serves 2 vital objectives. It cools down the transformer windings successfully during continual hefty procedure. It also offers excellent electric insulation, preventing harmful brief circuits. This dependability is important for substations sustaining essential commercial processes.

You locate these transformers directly inside devoted substation structures or safe outside rooms. They develop the core web link between the high-voltage grid and the regional industrial power network. Their primary feature is dispersing the stepped-down power reliably. They feed power straight to huge electric motors, hefty machinery, and substantial plant-wide electrical systems within manufacturing facilities, Minièren, or handling plants.

Dës Transformatoren sinn schwéier gebaut. They deal with the consistent, heavy electrical loads typical in market. The oil cooling system takes care of the substantial warm generated. This makes sure steady procedure night and day. Their design focuses on long life and very little downtime. This is critical for commercial operations where unanticipated power loss suggests significant production stops and monetary loss. They offer the steady, reputable power foundation industrial facilities definitely need.

Firma Profil

PDDN Photoelectron Technology Co., Ltd., Ltd. ass eng vun de féierende Entreprisen a Kraaftelektronik Technologie a Kraaftprodukter, déi voll an der Entwécklung vu Solarinverter involvéiert ass, transformers, Volt reegler, Verdeelung cabinets, thyristors, Moduler, dioden, Heizungen, an aner elektronesch Apparater oder semiconductors. Mir wäerten verpflichte Benotzer mat héich-Qualitéit ze bidden, effizient Produkter a virsiichteg Service.

Et akzeptéiert Bezuelen iwwer Kreditkaart, T/T, West Unioun, an Paypal. PDDN wäert d'Wueren u Clienten iwwerséiesch iwwer FedEx schécken, DHL, vum Mier, oder duerch Loft. If you want high-quality 10/11kV Industrial Oil Immersed Transformer for Electrical Substation, weg schéckt eis Ufroen; mir wäerten hei sinn fir Iech ze hëllefen.


Bezuelmethoden

L/C, T/T, Western Union, Paypal, Kreditkaart etc.


Sendung

Mam Mier, duerch Loft, duerch express, wéi Clienten Ufro.


Stockage Konditiounen

1) Store an engem dréchen Ëmfeld bei Raumtemperatur.

2) Vermeiden Feuchtigkeit an héich Temperaturen.

3) Benotzt direkt no der Ouverture vun der banneschten Verpackungsbeutel.

5 FAQs of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Here are five common questions about 10/11kV Industrial Oil Immersed Transformers for electrical substations:

Wat mécht dësen Transformator?
This transformer changes electricity’s voltage level. It steps down the high voltage electricity coming into the substation. It makes the voltage safe for factories or large buildings to use. It powers heavy machinery and equipment reliably.

Why use oil inside it?
Den Transformatorkär an d'Wicklungen sëtzen an engem speziellen Isoléierueleg. Dësen Ueleg mécht zwee Haaptaarbechten. Et killt d'Transformatordeeler wärend der Operatioun. Et bitt och vital elektresch Isolatioun. Oil cooling handles large power loads effectively. It keeps temperatures stable.

Wat sinn hir Haaptmerkmale?
These transformers are built tough for demanding industrial sites. They use strong steel tanks holding the oil and internal parts. Radiators or cooling fins attach to the tank. They help dissipate heat. Robust bushings safely bring the electrical cables in and out. Protective devices monitor oil levels and temperature. They give warnings if problems happen.

Ass et sécher?
Sécherheet ass eng Haaptprioritéit. The transformer tank is completely sealed. Dëst verhënnert Ueleg Leckage. Modern designs often include pressure relief devices. These protect the tank if internal pressure builds too high. Fire walls or special pits around the installation add extra safety. They contain any potential oil fire. Regular testing ensures it meets strict safety standards.

Wéi vill Ënnerhalt brauch et?
Oil immersed transformers need regular professional checks. Technicians test the oil quality often. They look for moisture or chemical breakdown. They inspect the physical condition of the tank, bushings, and cooling surfaces. They check all connections are tight. They confirm protective devices work correctly. Keeping the transformer clean and dry is also important. Proper maintenance extends its working life significantly. Et verhënnert onerwaart Feeler.

Ufro engem ZITAT

Ufro engem ZITAT