10/11Trasformatore industriale a bagno d'olio kV per sottostazione elettrica

PARAMETRI DEL PRODOTTO

Descrizione
RICHIEDI UN PREVENTIVO

Descrizione

Overview of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

Un trasformatore immerso in olio è un tipo di trasformatore elettrico in cui il nucleo e gli avvolgimenti sono immersi in un olio isolante. Questo olio svolge due funzioni principali: agisce come un isolante altamente efficace tra le parti conduttrici e come refrigerante per dissipare il calore generato durante il funzionamento. Questi trasformatori sono robusti, affidabile, e altamente efficiente, rendendoli la scelta standard per le reti di distribuzione e trasmissione di energia ad alta tensione, tipicamente installato all'aperto nelle sottostazioni.

Features of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

  • Raffreddamento efficace: L'olio isolante assorbe efficacemente il calore dal nucleo e dagli avvolgimenti e lo trasferisce alle alette del radiatore, consentendo la circolazione naturale o forzata e una maggiore capacità di sovraccarico.
  • Isolamento superiore: L'olio fornisce una rigidità dielettrica molto migliore rispetto all'aria, consentendo un design più compatto per una determinata tensione nominale e proteggendo dai cortocircuiti.
  • Costruzione robusta: Progettato per il lungo termine, funzionamento affidabile (Spesso 25-30 anni) in ambienti esterni difficili.
  • Capacità di sovraccarico: Può gestire sovraccarichi di potenza temporanei meglio dei trasformatori di tipo a secco grazie alla massa termica e alle proprietà di raffreddamento dell'olio.
  • Sistema di protezione: Dotato di serbatoio conservatore (per consentire l'espansione dell'olio), respiro (per assorbire l'umidità dall'aria), e relè di protezione (Staffetta Buchholz) per il rilevamento dei guasti interni.
  • Conveniente: Generalmente più economico per applicazioni ad alta potenza rispetto ai trasformatori a secco.

Specifications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

This transformer handles heavy commercial lots. It steps down voltage for substation use. The main voltage rating is 10kV or 11kV. The secondary voltage matches your certain devices needs. Typical options include 400V, 415V, O 6.6 kV. This flexibility is necessary.

Il nucleo utilizza acciaio elettrico di alta qualità. Ciò riduce al minimo le perdite di potenza. Gli avvolgimenti sono in rame. Copper provides excellent conductivity. This ensures reliable power transfer. The whole assembly rests inside a durable steel storage tank. The tank is full of top notch protecting oil. The oil cools down the transformer. The oil likewise supplies important electrical insulation.

Different air conditioning methods are available. ONAN (Olio Naturale Aria Naturale) is conventional. Air flows normally over cooling radiators. ACCESO SPENTO (Olio Naturale Aria Forzata) uses followers. Followers enhance cooling down ability. This suits higher need scenarios. The transformer withstands harsh problems. It runs dependably in high ambient temperatures.

Le funzionalità di sicurezza sono integrate. A stress alleviation device secures versus inner mistakes. An oil level gauge reveals the oil volume. A temperature level sign checks operating warm. These features protect against damages. They ensure lengthy life span.

The transformer meets strict international standards. CEI 60076 is crucial. Ciò garantisce prestazioni e sicurezza. Building concentrates on long life. It manages regular tons changes. It sustains electrical surges common in substations. Marginal upkeep is required. This reduces functional expenses.

Power performance is a concern. Low no-load losses conserve power. Low tons losses minimize waste throughout procedure. This transformer gives reputable power distribution. It develops the foundation of your substation. Its durable layout makes sure continual operation.

Applications of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

These 10/11kV oil-immersed transformers are important for power substations. They step down high voltage electrical power from the main grid. This reduced voltage is secure for circulation inside commercial sites. Impianti di produzione, miniere, big processing plants rely on them. They give stable power for heavy machinery. Motori, linee di produzione, big illumination systems require this power.

Their layout uses mineral oil. This oil serves two tasks. It cools down the transformer components. It likewise protects online elements. This oil bath makes them very trustworthy. They take care of challenging problems well. Warmth build-up is much less of a problem. They can take care of brief overloads much better than completely dry kinds. This issues throughout top commercial need.

These transformers are constructed strong. They function outdoors in substations. Weather, polvere, temperature level swings don’t stop them. Their durable storage tank shields the core and windings. Workers can keep them quickly. Oil levels and problem are basic to check. Safety functions like pressure safety valve are common. They protect against failings if troubles occur inside.

Substations position them near the tons facility. This decreases long low-voltage wire runs. Much less power obtains shed over distance. Voltage stays stable at the equipment. The transformer links straight to the substation switchgear. This produces a safe power center for the entire enterprise zone. Ports, large commercial facilities, utility booster terminals additionally use them. They are a typical, proven solution for trusted medium-voltage power conversion.

Profilo Aziendale

PDDN Photoelectron Technology Co., Ltd. è una delle aziende leader nella tecnologia dell'elettronica di potenza e nei prodotti energetici, che è pienamente coinvolta nello sviluppo di inverter solari, trasformatori, regolatori di tensione, armadi di distribuzione, tiristori, moduli, diodi, riscaldatori, e altri dispositivi elettronici o semiconduttori. Ci impegneremo a fornire agli utenti prodotti di alta qualità, prodotti efficienti e servizio premuroso.

Accetta il pagamento tramite Carta di Credito, T/T, Unione occidentale, e Paypal. PDDN spedirà la merce ai clienti all'estero tramite FedEx, DHL, via mare, o per via aerea. If you want high-quality 10/11kV Industrial Oil Immersed Transformer for Electrical Substation, vi preghiamo di inviarci richieste; saremo qui per aiutarti.


Metodi di pagamento

L/C, T/T, Unione occidentale, PayPal, Carta di credito ecc.


Spedizione

Via mare, per via aerea, per espresso, come richiedono i clienti.


Condizioni di conservazione

1) Conservare in un ambiente asciutto a temperatura ambiente.

2) Evitare l'umidità e le alte temperature.

3) Utilizzare immediatamente dopo aver aperto la confezione interna.

5 FAQs of 10/11kV Industrial Oil Immersed Transformer for Electrical Substation

What is a 10/11kV oil immersed transformer?
Questo trasformatore trasforma l'elettricità ad alta tensione in una tensione più bassa. It uses special oil inside its tank. L'olio raffredda il trasformatore. L'olio isola anche le parti interne. It handles voltages like 10,000 volt o 11,000 volt. This is common for industrial power distribution.

Dove viene solitamente utilizzato questo trasformatore??
You find this transformer inside electrical substations. Substations serve factories, grandi edifici, e parchi industriali. They are the main point for stepping down high voltage from the grid. They supply the safer, usable voltage for machines and equipment inside the facility.

Quali sono le sue caratteristiche principali?
This transformer uses mineral oil for cooling and insulation. It has a strong steel tank protecting the core and windings. It has bushings for connecting high voltage and low voltage cables. It includes safety devices. These are things like pressure relief valves and temperature gauges. It is built tough for reliable outdoor or indoor substation use.

È sicuro??
La sicurezza è un obiettivo importante. The tank is very strong. It contains the oil under normal conditions. Special safety valves release pressure if internal faults happen. Ciò impedisce pericolose esplosioni. The oil itself helps stop electrical arcs inside. Regular testing ensures it meets strict safety standards for industrial sites.

Come lo mantengo??
Regular checks are vital. You must monitor the oil level inside the tank. Look for leaks around the tank welds or gaskets. Check the color of the silica gel in the breather; change it when it turns pink. Take oil samples for lab testing. This checks the oil’s insulating quality and finds hidden problems. Keep the transformer and its cooling radiators clean. Follow the manufacturer’s specific maintenance schedule closely.

RICHIEDI UN PREVENTIVO