Trefaset oljenedsenket krafttransformator, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

PRODUKTPARAMETRE

Beskrivelse
BE ET TILBUD

Beskrivelse

Overview of Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

En oljenedsenket transformator er en type elektrisk transformator der kjernen og viklingene er nedsenket i en isolerende olje. Denne oljen har to hovedfunksjoner: den fungerer som en svært effektiv isolator mellom ledende deler og som et kjølemiddel for å spre varme som genereres under drift. Disse transformatorene er robuste, pålitelig, og svært effektiv, gjør dem til standardvalget for distribusjons- og overføringsnett med høyspent kraft, vanligvis installert utendørs i transformatorstasjoner.

Features of Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

  • Effektiv kjøling: Den isolerende oljen absorberer effektivt varme fra kjernen og viklingene og overfører den til radiatorfinnene, gir mulighet for naturlig eller tvungen sirkulasjon og høyere overbelastningskapasitet.
  • Overlegen isolasjon: Oljen gir mye bedre dielektrisk styrke enn luft, muliggjør en mer kompakt design for en gitt spenningsklassifisering og beskytter mot kortslutninger.
  • Robust konstruksjon: Designet for langsiktig, pålitelig drift (ofte 25-30 år) i tøffe utemiljøer.
  • Overbelastningskapasitet: Kan håndtere midlertidige strømoverbelastninger bedre enn transformatorer av tørr type på grunn av oljens termiske masse og kjøleegenskaper.
  • Beskyttelsessystem: Utstyrt med konservatortank (for å tillate oljeutvidelse), pusterom (å absorbere fuktighet fra luft), og beskyttelsesreléer (Buchholz stafett) for intern feildeteksjon.
  • Kostnadseffektiv: Generelt mer økonomisk for høyeffektapplikasjoner sammenlignet med transformatorer av tørr type.

Specifications of Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

This transformer manages three-phase power systems. It beings in oil for air conditioning and insulation. Typical voltage scores are 11kV and 6kV. Power capabilities consist of 160kVA, 250kVA, and 315kVA models. These dimensions fit several commercial and business requirements. The oil cooling is dependable and efficient. It keeps the transformer running cool under lots. The core and windings use top quality materials. This ensures stable voltage output and minimal losses. The entire device is built hard inside a steel storage tank. This protects it from climate and harsh conditions.

Oppsettet er ukomplisert. It requires a strong, gradsgrunnlag. Proper grounding is necessary for safety and security. Regular checks on the oil degree and condition are necessary. Upkeep is typically easy. The design concentrates on lengthy service life. These transformers fulfill tough safety and security rules. They have defense versus overloads and brief circuits. This makes them trustworthy for continuous operation.

We likewise supply present transformers (CT-er). CTs determine high currents safely. They tip down the current for meters and defense devices. CTs are important for accurate monitoring and control. They can be found in numerous proportions and precision courses. CTs function well with our power transformers.

High-frequency transformers are different. They operate at much faster changing speeds. These are except common power distribution. High-frequency types are for specialized electronics. Examples include switch-mode power supplies and inverters. They handle quick modifications in voltage and present. Their style makes use of unique materials for core loss decrease. Size is typically much smaller sized than power frequency units.

Applications of Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

Power transformers take care of electricity safely and effectively. Three-phase oil-immersed kinds are common for sturdy jobs. They utilize oil to protect and keep one’s cool. You discover them tipping voltage up or down. Usual voltages are 11kV and 6kV. Sizes like 160kVA, 250kVA, and 315kVA fit many demands. Manufacturing facilities utilize these transformers. Mines utilize them too. They power huge motors and machinery accurately. Substations rely upon them for local power circulation. They manage constant high lots well. The oil cooling makes them durable for challenging atmospheres. These transformers create the foundation of industrial power grids.

Present transformers, or CTs, are different. They do not change voltage much. Their task is measuring present safely. They step down high existing to a reduced, manageable level. Meters utilize this low signal. Protective relays use it also. You install CTs around a major power line. They let tools monitor flow without straight high-current call. This is vital for safety and security and control. Every power system needs CTs for accurate tracking and defense.

High-frequency transformers run in different ways. They work with fast-changing currents, not the typical 50Hz or 60Hz grid power. Electronics use them for changing power products. These supplies convert power efficiently. You find them in computers. Telecom tools uses them. Industrial inverters need them. Clinical devices use high-frequency transformers. Their layout uses unique cores, frequently ferrite, not iron. This minimizes energy loss at high frequencies. They are smaller than power transformers for the very same power level. Their function is allowing compact, efficient power conversion in modern electronic systems.

Bedriftsprofil

PDDN Photoelectron Technology Co., Ltd. er en av de ledende foretakene innen kraftelektronikkteknologi og kraftprodukter, som er fullt involvert i utviklingen av solcelle-omformere, transformatorer, spenningsregulatorer, distribusjonsskap, tyristorer, moduler, dioder, varmeovner, og andre elektroniske enheter eller halvledere. Vi vil være forpliktet til å gi brukerne høy kvalitet, effektive produkter og hensynsfull service.

Den aksepterer betaling med kredittkort, T/T, West Union, og Paypal. PDDN vil sende varene til kunder i utlandet gjennom FedEx, DHL, til sjøs, eller med fly. If you want high-quality Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator, vennligst send oss ​​forespørsler; vi vil være her for å hjelpe deg.


Betalingsmetoder

L/C, T/T, Western Union, Paypal, Kredittkort etc.


Forsendelse

Ved sjøen, med fly, ved ekspress, som kundene ber om.


Oppbevaringsbetingelser

1) Oppbevares i et tørt miljø ved romtemperatur.

2) Unngå fuktighet og høy temperatur.

3) Brukes umiddelbart etter at den indre pakningsposen er åpnet.

5 FAQs of Three-phase Oil-immersed Power Transformer, 11kv, 6kv, 160kva, 250kva, 315kva, Nåværende transformator, Høyfrekvent transformator

Here are key questions customers ask about our three-phase oil-immersed power transformers (11kV, 6kV, 160kva, 250kva, 315kva), current transformers, and high-frequency transformers:

What jobs do these transformers handle?
Our oil-immersed power transformers manage power distribution in factories, bygninger, og transformatorstasjoner. They step down higher voltages like 11kV or 6kV to usable levels. Current transformers accurately measure large electrical currents safely. High-frequency transformers work in specialized equipment needing fast switching, like certain power supplies or converters.

Hvordan velger jeg riktig størrelse (kva)?
Choosing the correct kva rating is vital. Først, calculate your total connected load. Consider future expansion needs. Factor in the starting currents of large motors. Our 160kva, 250kva, and 315kva models cover common industrial needs. Underdimensjonering forårsaker overoppheting. Oversizing wastes money and efficiency. We help you select the perfect match.

Er disse transformatorene trygge?
Sikkerhet er innebygd. The oil insulation cools the core and windings effectively. It also suppresses internal arcs. Robust steel tanks protect the internal parts. Reliable bushings prevent oil leaks at connection points. Key safety devices like the Buchholz relay detect internal gas buildup from faults. Pressure relief valves vent excess pressure safely.

Hvilket vedlikehold som trengs?
Regular checks keep them reliable. Monitor the oil level in the sight gauge frequently. Inspect for any oil leaks around gaskets and valves. Periodically test the oil’s insulation strength and check for moisture or contaminants. We test oil samples. Listen for unusual humming or vibrations indicating loose parts. Schedule professional inspections annually.

Can you make custom transformers?
Vi tilbyr tilpasning. Need a specific voltage ratio not listed? We can design it. Require special tap changers for voltage adjustment? We include them. Need unique mounting brackets or special terminal arrangements? We build that. Current transformers get tailored ratios. High-frequency units meet exact inductance and frequency specs. Fortell oss dine krav.

BE ET TILBUD

BE ET TILBUD