Leverandør av elektroniske komponenter | Transformatorer, Induktorer, Invertere
PRODUKTPARAMETRE
Beskrivelse
Overview of Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers
Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers is the primary insulation device outside the transformer box, brukes til å sikre isolasjonen av transformatorviklingsledningene. Den består av flere deler, inkludert den sentrale isolerte kondensatorkjernen, utvendige isolerte øvre og nedre porselenskomponenter, osv. I henhold til spenningsnivået, det finnes ulike former for bøssinger, som ren keramikk, oljefylte foringer, og kondensatorforinger. Under drift av en transformator, isolasjonshylsen som viklingen fører gjennom er en av dens strømførende komponenter, som må tåle belastningsstrømmen og kortslutningsstrømmen.
Characteristics of Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers
Utmerket elektrisk isolasjonsytelse: Det kan effektivt forhindre de negative effektene av strøm på ledninger, kabler, eller utstyr.
Høy temperatur motstand: Laget av materialer som tåler høye temperaturer, den kan opprettholde utmerket ytelse i miljøer med høy temperatur.
Korrosjonsbestandighet: Det kan effektivt forhindre at kjemiske stoffer forårsaker korrosjonsskader på ledninger, kabler, eller utstyr.
Antialdringsytelse: Oppretthold stabil ytelse ved langvarig bruk og forleng levetiden effektivt.
God mekanisk styrke og tetningsytelse: i stand til å motstå øyeblikkelig overoppheting ved kortslutning, med et lite utseende, liten vekt, god tetningsevne, sterk allsidighet, og enkelt vedlikehold.”
Specification of Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers
This fiberglass heat insulation sleeving with silicone coating protects motors and transformers. It stops heat and electrical problems. The main material is strong fiberglass. This fiberglass handles very high heat. The fiberglass gets a special silicone coating. This coating makes the sleeving much better. It seals the material. This stops moisture and chemicals getting inside. The coating also makes the surface smooth. This helps the sleeving slide on easily over wires or parts. It protects against cuts and scratches too.
The sleeving works in very hot places. It handles temperatures up to 500 degrees Fahrenheit or 260 grader Celsius. This is important inside motors and transformers. These machines get extremely hot when running. The sleeving keeps the heat inside the wires. This stops heat from escaping to other parts. It helps the equipment run cooler and last longer. It saves energy also.
Electrical safety is critical. This sleeving has high dielectric strength. Det forhindrer elektrisk kortslutning. It stops electricity jumping between wires or to the machine frame. This protects people and the equipment itself. The silicone coating helps with this electrical insulation. It adds an extra protective layer.
The sleeving is flexible and light. You can bend it easily around tight corners and complex shapes inside motors or transformers. It doesn’t add much weight. It stays strong under vibration and movement. It resists many oils, drivstoff, og vanlige kjemikalier. This prevents damage from leaks or spills. The material won’t easily catch fire either. It meets important safety standards for flame resistance.
People use this sleeving mainly on motor windings and transformer coils. It wraps around the copper wires carrying electricity. It insulates individual wires or bundles of wires. It protects connection points like leads and terminals. It shields other sensitive parts inside the equipment from heat and electrical interference.
Applications of Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers
Fiberglass heat insulation sleeving with silicone coating protects motors and transformers well. This material handles high heat. It shields wires and parts inside motors and transformers. This prevents heat damage. Motors get hot running. Transformers create heat too. This sleeving keeps that heat away from sensitive areas. It stops overheating. This helps equipment last longer. It lowers the risk of fire.
Electrical safety matters a lot. This sleeving insulates electrically. It stops electricity jumping where it shouldn’t. Dette forhindrer shorts. It protects people working near the equipment. Motors and transformers use high voltage. Good insulation is essential. The silicone coating adds this protection. It blocks electricity flow over the surface.
The sleeving is tough. It resists cuts and scrapes. Motors vibrate constantly. Handling during installation can cause nicks. The fiberglass base is strong. The silicone coating makes it slippery. This helps it slide over parts easily. It also resists tearing. This durability means less replacement. Equipment runs longer without maintenance.
Chemicals are a problem. Olje, fuel, and solvents can damage insulation. This sleeving resists many chemicals. Spills happen in workshops. Leaks occur in engines. The silicone coating keeps these liquids out. It stops the insulation breaking down. This maintains its protective job.
Installing this sleeving is straightforward. It fits over wires and components easily. Mechanics can cut it to the right length quickly. It stays flexible even in cold places. This makes fitting it around tight corners simple. It saves time during repairs or building new units. Workers appreciate products that are easy to use.
Bedriftsprofil
PDDN Photoelectron Technology Co., Ltd. er en av de ledende foretakene innen kraftelektronikkteknologi og kraftprodukter, som er fullt involvert i utviklingen av solcelle-omformere, transformatorer, spenningsregulatorer, distribusjonsskap, tyristorer, moduler, dioder, varmeovner, og andre elektroniske enheter eller halvledere. Vi vil være forpliktet til å gi brukerne høy kvalitet, effektive produkter og hensynsfull service.
Den aksepterer betaling med kredittkort, T/T, West Union, og Paypal. PDDN vil sende varene til kunder i utlandet gjennom FedEx, DHL, til sjøs, eller med fly. If you want high-quality Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers, vennligst send oss forespørsler; vi vil være her for å hjelpe deg.
Betalingsmetoder
L/C, T/T, Western Union, Paypal, Kredittkort etc.
Forsendelse
Ved sjøen, med fly, ved ekspress, som kundene ber om.
Oppbevaringsbetingelser
1) Oppbevares i et tørt miljø ved romtemperatur.
2) Unngå fuktighet og høy temperatur.
3) Brukes umiddelbart etter at den indre pakningsposen er åpnet.
5 FAQs of Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers
Her er 5 FAQs about Fiberglass Heat Insulation Sleeving with Silicone Coating for Motors and Transformers:
What is this sleeving? It’s a protective sleeve made from woven fiberglass. The fiberglass gets a silicone rubber coating. This combination shields wires and parts inside motors and transformers from intense heat.
Hvor varmt kan det bli? This sleeving handles very high temperatures. It works reliably up to 500°F (260°C). It protects components from heat damage in demanding electrical equipment.
Why the silicone coating? The silicone adds crucial benefits. It makes the sleeve flexible and easy to install. It seals the fiberglass, stopping moisture, støv, and chemicals from getting inside. This prevents corrosion and electrical problems. The coating also makes the sleeve tougher against abrasion and tearing.
How do you put it on? Installasjonen er enkel. Measure the length you need. Cut the sleeving with sharp scissors. Slide the sleeve directly over the wire or component. The silicone coating helps it slide smoothly into place. Ensure the fit is snug but not overly tight.
Hvordan velger jeg riktig størrelse? Choosing the correct inner diameter is vital. Measure the part you need to cover. Pick a sleeve size slightly larger than this measurement. This allows easy sliding. But avoid a size too big. A loose sleeve won’t stay put properly and offers less protection.
BE ET TILBUD
RELATERTE PRODUKTER

Beskyttelsesdeksel Silikongummitransformator Isolasjonskappe Transformatorbøssingsdeksel for transformator

Elektrisk isolasjonsbelagt glassfiberhylse Isolerende isolasjon Glassfiberhylse for elektrisk motorvikling

Strømtransformator eller motoromvikling isolerende glassfiberflettet hylse Pvc isolasjonsmateriale glassfiberhylse 2715

Varmebestandig 1,5 kv 2,5 kv elektrisk isolasjon Glassfiberbelagt PVC-fiberglasshylse 2715 Pvc-hylse for kabel

10kV epoksyharpiksisolasjonshylse for høyspent PT-håndvogn Potensial Transformator Isolator Isolasjonsmaterialer Elementer