Electronic Components Supplier | Transformers, Inductors, Inverters
PRODUCT PARAMETERS
Description
Overview of Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer
An oil-immersed transformer is a type of electrical transformer where the core and windings are submerged in an insulating oil. This oil serves two primary functions: it acts as a highly effective insulator between conductive parts and as a coolant to dissipate heat generated during operation. These transformers are robust, reliable, and highly efficient, making them the standard choice for high-voltage power distribution and transmission networks, typically installed outdoors in substations.
Features of Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer
- Effective Cooling: The insulating oil efficiently absorbs heat from the core and windings and transfers it to the radiator fins, allowing for natural or forced circulation and higher overload capacity.
- Superior Insulation: The oil provides much better dielectric strength than air, allowing for a more compact design for a given voltage rating and protecting against short circuits.
- Robust Construction: Designed for long-term, reliable operation (often 25-30 years) in harsh outdoor environments.
- Overload Capacity: Can handle temporary power overloads better than dry-type transformers due to the thermal mass and cooling properties of the oil.
- Protection System: Equipped with a conservator tank (to allow for oil expansion), breather (to absorb moisture from air), and protective relays (Buchholz relay) for internal fault detection.
- Cost-Effective: Generally more economical for high-power applications compared to dry-type transformers.
Specifications of Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer
This transformer handles heavy industrial power demands. It’s ranked for 4000 KVA or 4 MVA. This indicates it handles big electric lots reliably. The three-phase design fits manufacturing facilities and huge facilities.
It utilizes oil for insulation and air conditioning. The oil circulates normally around the core and windings. This maintains temperatures safe during procedure. The air conditioning type is ONAN (Oil Natural Air Natural). This is simple and trustworthy.
The core utilizes top-quality silicon steel. This lowers power losses significantly. The windings are copper for reliable power transfer. They are very carefully scheduled stability. The entire assembly rests inside a solid, welded steel tank. This storage tank holds the protecting oil safely.
Common voltage ratings prevail. Main might be 11kV, 15kV, 22kV, or 33kV. Secondary could be 0.415 kV, 3.3 kV, 6.6 kV, or 11kV. Other voltages are possible. Resistance is normally around 6%, but it can be adjusted. This regulates fault currents efficiently.
Power losses are an essential emphasis. The layout lessens no-load loss and tons loss. This conserves cash over the transformer’s long life. Insulation course is generally Class A. The BIL (Basic Impulse Level) is high. This shields against voltage rises.
The transformer runs quietly. Sound levels are maintained low. Temperature level surge is limited. It stays well below safety margins. The tank consists of functions for easy upkeep. There’s an oil conservator, a rest, and a Buchholz relay. The relay identifies inner faults swiftly.
Extensive testing guarantees top quality. Each system passes regular checks. Type examinations and special examinations are also executed. Requirements like IEC 60076 or IEEE C57.12.00 are adhered to. This guarantees security and efficiency.
Applications of Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer
3 phase oil submersed 4000 KVA (4 MVA) power transformers deal with big electrical loads accurately. They are vital devices where substantial power distribution or voltage change is needed. Utilities use these transformers thoroughly. They step down high transmission voltages to much safer, reduced levels for neighborhood distribution networks feeding communities, industrial parks, or large business complexes. This makes certain power reaches end-users efficiently and safely.
Industries depend on these durable transformers. Manufacturing facilities, chemical plants, mines, and huge manufacturing centers need steady, high-capacity power. The 4000 KVA system supplies the necessary change point within their interior electric systems. It powers hefty equipment, huge electric motors, and substantial handling lines without disturbance. Oil immersion successfully cools the transformer windings and core during continual durable procedure.
Renewable energy tasks also utilize these transformers. Solar farms and wind installments create power, usually at tool voltage levels. The 4000 KVA transformer boosts this voltage for efficient transmission over longer ranges to the primary grid connection factor. This reduces power losses during transportation.
Huge facilities jobs require trustworthy power circulation. Airport terminals, ports, health centers, university schools, and significant information facilities all have considerable electricity needs. These transformers develop vital nodes within their dedicated electric circulation grids, making certain constant power circulation to vital systems and structures. They are frequently set up in substations on-site.
Their robust oil-immersed layout makes them ideal for requiring environments. They offer excellent security against overloads and supply steady operation over extended periods. This reliability is vital for mission-critical procedures. They likewise function as crucial parts in backup power systems for necessary centers.
Company Profile
PDDN Photoelectron Technology Co., Ltd. is one of the leading enterprises in power electronics technology and power products, which is fully involved in developing solar inverters, transformers, voltage regulators, distribution cabinets, thyristors, modules, diodes, heaters, and other electronic devices or semiconductors. We will be committed to providing users with high-quality, efficient products and considerate service.
It accepts payment via Credit Card, T/T, West Union, and Paypal. PDDN will ship the goods to customers overseas through FedEx, DHL, by sea, or by air. If you want high-quality Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer, please send us inquiries; we will be here to help you.
Payment Methods
L/C, T/T, Western Union, Paypal, Credit Card etc.
Shipment
By sea, by air, by express, as customers request.
Storage Conditions
1) Store in a dry environment at room temperature.
2) Avoid damp and high temperature.
3) Use immediately after opening the inner packing bag.
5 FAQs of Three Phase Oil Immersed 4000 KVA 4 MVA Power Transformer
What does this transformer do?
This 4000 KVA oil-filled transformer handles large amounts of electricity. It steps voltage up or down. This is vital for efficient power transmission over long distances or supplying factories.
Why is it filled with oil?
The oil serves two main jobs. It cools the transformer’s core and windings during operation. The oil also acts as a powerful electrical insulator. This prevents dangerous short circuits inside the unit.
Where is this transformer typically used?
You find this transformer in demanding industrial settings. Large factories, major mining operations, and big infrastructure projects need its high capacity. Utility substations also use it within power distribution grids.
How safe is the oil inside?
The oil is highly refined mineral oil. It’s stable and non-explosive under normal conditions. The transformer tank is welded steel. It is built strong to contain the oil safely. Pressure relief devices protect against extreme internal faults.
What maintenance does it need?
Regular checks are essential. Technicians monitor oil levels and test oil quality for breakdown. They inspect bushings, connections, and cooling radiators. External cleaning keeps surfaces free from dirt. Internal inspections require specialized service.