Proveedor de componentes electrónicos | Transformadores, Inductores, Inversores
PARÁMETROS DEL PRODUCTO
Descripción
Overview of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer
Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer is an enclosed, Transformador de distribución eléctrica a nivel del suelo comúnmente utilizado en el subsuelo. (y) sistemas de energía. Reduce la electricidad primaria de alto voltaje (p.ej., 15kV o 25kV) a un voltaje secundario más bajo (p.ej., 120/240V o 480V) para una distribución segura en barrios residenciales, edificios comerciales, y parques industriales. Es robusto, El recinto de acero con cerradura lo hace seguro para áreas públicas.
Features of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer
Cerramiento a nivel del suelo: un cerrado, resistente a manipulaciones, Gabinete de acero resistente a la intemperie que protege los componentes internos y garantiza la seguridad pública..
Conexiones de cables subterráneos: Diseñado para una fácil conexión a la primaria subterránea (de alta tensión) y secundaria (bajo voltaje) cables a través de compartimentos con pasatapas incorporados.
Compartimentación: Separado, Compartimentos aislados para componentes de alto y bajo voltaje., mejorar la seguridad durante el mantenimiento.
Ventilación: Diseñado con rejillas u otros sistemas de ventilación para permitir una disipación de calor adecuada desde el núcleo del transformador y las bobinas..
Orejas de elevación: Orejas de elevación integradas para una instalación y sustitución fáciles y seguras mediante una grúa o un polipasto.
Hardware a prueba de manipulaciones: Puertas con cerradura con pernos especiales para evitar el acceso no autorizado..
Interruptores fusionados: A menudo incluye interruptores de desconexión con fusibles para protección del circuito y aislamiento seguro..
Base de almohadilla: Instalado sobre una plataforma de concreto. (“montado en plataforma”) para proporcionar un establo, base de nivel.
Specifications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer
Pad-mounted transformers provide trusted power for commercial and industrial requirements. These systems tip down higher circulation voltages to functional degrees. Common options consist of 13.2 kV, 23kV, and 35kV main voltages. Standard abilities are 75kVA, 112.5 kVA, 160kVA, and as much as 500kVA. This range covers several applications properly.
The transformer sits firmly inside a durable, weatherproof steel unit. This unit is developed for ground-level setup straight on a concrete pad. It safeguards the core and coil assembly inside. This configuration maintains the transformer risk-free outdoors. It withstands extreme weather conditions year-round.
La seguridad es crítica. These transformers feature tamper-proof styles. Locking doors avoid unapproved accessibility to live components. This shields people and building. The rooms likewise fulfill certain security standards. They are developed difficult for public areas near structures or car park.
Performance issues for cost financial savings. Modern pad-mounted transformers use top notch core steel and windings. Esto reduce las pérdidas de energía durante el funcionamiento.. Reduced losses mean reduced electrical power costs over the transformer’s lengthy lifespan. They operate reliably for several years.
La configuración es sencilla. The pad-mounted layout removes the need for posts or devoted frameworks. It conserves area and streamlines website preparation. Energies and services appreciate this functional service. Upkeep gain access to is additionally practical through the enclosure doors. Specialists can perform assessments and service quickly.
These transformers connect cleanly to underground power line. They develop a vital web link in between the utility grid and the end-user’s electric system. Typical uses include shopping mall, colegios, fábricas, and workplace parks. They give the needed power step-down successfully. The specific voltage and kVA ranking is chosen based upon the tons requirements. Correct sizing ensures optimal efficiency and durability.
Applications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer
Pad installed transformers deal with important power tasks. They tip down greater voltage electrical energy to levels risk-free for everyday use. You see them commonly in communities. They provide power to groups of homes or apartment. These systems prevail. They sit on concrete pads right at ground level. This makes them protected and easy to reach for solution. Their hard steel cases shield the equipment inside from climate and people touching them. They are built for outside use.
Services rely on these transformers also. Los centros comerciales los utilizan. Office buildings require them. They supply the appropriate power for lights, sistemas informáticos, and machines. Manufacturing facilities set up pad placed transformers. They power heavy devices dependably. Medical facilities depend upon them for important treatment locations. Places requiring constant power pick these systems. son confiables.
Various sizes exist for different requirements. Smaller systems, like 75kVA or 112.5 kVA, typically serve tiny industrial buildings or a couple of houses. Larger sizes, like 160kVA or 500kVA, deal with larger loads. They power bigger shops, bigger groups of homes, or commercial devices. The voltage issues. Systems rated for 13.2 kV, 23kV, or 35kV link to various power lines located in different locations. This flexibility is crucial.
Renewable resource jobs use pad installed transformers. They link solar farms or wind turbines to the grid. The power produced needs transforming. These devices do that work well. They match limited areas conveniently. Their small layout is a big advantage. They maintain the power streaming securely. They are a vital part of the electric system.
Perfil de la empresa
PDDN Photoelectron Technology Co., Limitado. es una de las empresas líderes en tecnología de electrónica de potencia y productos de energía., que participa plenamente en el desarrollo de inversores solares, transformadores, reguladores de voltaje, gabinetes de distribución, tiristores, módulos, diodos, calentadores, y otros dispositivos electrónicos o semiconductores. Nos comprometeremos a proporcionar a los usuarios alta calidad., Productos eficientes y servicio considerado..
Acepta pago mediante Tarjeta de Crédito, T/T, Unión Oeste, y paypal. PDDN enviará los productos a clientes en el extranjero a través de FedEx, DHL, por mar, o por aire. If you want high-quality Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer , por favor envíenos sus consultas; estaremos aquí para ayudarte.
Métodos de pago
carta de crédito, T/T, Western Union, PayPal, Tarjeta de crédito, etc..
Envío
Por mar, en avión, por expreso, como los clientes lo solicitan.
Condiciones de almacenamiento
1) Almacenar en un ambiente seco a temperatura ambiente..
2) Evite la humedad y las altas temperaturas..
3) Úselo inmediatamente después de abrir la bolsa de embalaje interior..
5 FAQs of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer
Check your voltage first. Pad mounted transformers handle different primary voltages like 13.2kV, 23kV, or 35kV. You must pick the exact voltage your power line uses. These voltages are not interchangeable. Getting the voltage wrong causes major problems.
How big a transformer do you need? Sizes like 75kVA, 112.5kVA, 160kVA, and 500kVA are common. Choose based on your actual power demand. Don’t guess. Look at your peak electrical load. Picking a transformer too small overloads it. Picking one too big wastes money. Match the kVA rating to your measured load.
La seguridad importa. Estas unidades están construidas de manera resistente. They sit outside near people. Expect strong, tamper-proof steel enclosures. Las puertas se cierran de forma segura. Internal designs often resist electrical arcs. Good ventilation prevents overheating. The design keeps the public safe.
Maintenance is usually low. These transformers are sealed units. You don’t service them daily. Los controles de rutina son esenciales. Busque fugas de aceite. Listen for unusual humming sounds. Check cooling fins aren’t blocked. Monitorear los medidores de temperatura.. Mantenga despejada el área alrededor del transformador.. Professional inspections every few years are smart.
Installation needs planning. The transformer sits on a solid concrete pad. The pad must be perfectly level. It must support the heavy weight. Leave enough space all around. Workers need room for safe cable connections. Workers need room for future checks. Follow the manufacturer’s spacing rules exactly. Proper clearances prevent accidents.
SOLICITAR COTIZACIÓN
PRODUCTOS RELACIONADOS

25Ideal duradero confiable del diseño montado en cojín del transformador monofásico de KVA para las áreas rurales

Transformador montado en plataforma de distribución, frecuencia de 50 Hz y 60 Hz, la mejor

Transformadores eléctricos s, transformador reductor montado en almohadilla de 300kva, transformador de baja frecuencia de 220v a 110v 2000w

Transformador montado en plataforma para exteriores, 100kva, 200kva, tanque de aceite, 30kv/33kv/34,5kv/35kv, transformador de 250kva

Transformador monofásico de aluminio o cobre, transformador de distribución montado en almohadilla IEEE personalizado de 50kVA y 60Hz