Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

PRODUCTPARAMETERS

Beschrijving
VRAAG EEN OFFERTE AAN

Beschrijving

Overview of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer is an enclosed, elektrische distributietransformator op grondniveau die gewoonlijk ondergronds wordt gebruikt (En) energiesystemen. Het verlaagt de primaire hoogspanningselektriciteit (bijv., 15kV of 25 kV) naar een lagere secundaire spanning (bijv., 120/240V of 480V) voor een veilige distributie naar woonwijken, commerciële gebouwen, en industrieparken. Het is robuust, afsluitbare stalen behuizing maakt het veilig voor openbare ruimtes.

Features of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Behuizing op grondniveau: Een vergrendeld, fraudebestendig, weerbestendige stalen kast die de interne componenten beschermt en de openbare veiligheid garandeert.

Ondergrondse kabelverbindingen: Ontworpen voor eenvoudige aansluiting op ondergrondse primaire aansluitingen (hoogspanning) en secundair (laagspanning) kabels via compartimenten met ingebouwde bussen.

Compartimentering: Verschillend, geïsoleerde compartimenten voor hoogspannings- en laagspanningscomponenten, het vergroten van de veiligheid tijdens onderhoud.

Ventilatie: Ontworpen met lamellen of andere ventilatiesystemen om een ​​goede warmteafvoer van de transformatorkern en spoelen mogelijk te maken.

Hijsogen: Geïntegreerde hijsogen voor eenvoudige en veilige installatie en vervanging met behulp van een kraan of takel.

Fraudebestendige hardware: Afsluitbare deuren met speciale grendels om ongeautoriseerde toegang te voorkomen.

Gezekerde schakelaars: Bevat vaak gezekerde scheidingsschakelaars voor circuitbescherming en veilige isolatie.

Stichting Pad: Geïnstalleerd op een betonnen pad (“op pad gemonteerd”) een stal te bieden, vlakke basis.

Specifications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad-mounted transformers provide trusted power for commercial and industrial requirements. These systems tip down higher circulation voltages to functional degrees. Common options consist of 13.2 kV, 23kV, and 35kV main voltages. Standard abilities are 75kVA, 112.5 kVA, 160kVA, and as much as 500kVA. This range covers several applications properly.

The transformer sits firmly inside a durable, weatherproof steel unit. This unit is developed for ground-level setup straight on a concrete pad. It safeguards the core and coil assembly inside. This configuration maintains the transformer risk-free outdoors. It withstands extreme weather conditions year-round.

Veiligheid is van cruciaal belang. These transformers feature tamper-proof styles. Locking doors avoid unapproved accessibility to live components. This shields people and building. The rooms likewise fulfill certain security standards. They are developed difficult for public areas near structures or car park.

Performance issues for cost financial savings. Modern pad-mounted transformers use top notch core steel and windings. This reduces power losses during operation. Reduced losses mean reduced electrical power costs over the transformer’s lengthy lifespan. They operate reliably for several years.

De installatie is eenvoudig. The pad-mounted layout removes the need for posts or devoted frameworks. It conserves area and streamlines website preparation. Energies and services appreciate this functional service. Upkeep gain access to is additionally practical through the enclosure doors. Specialists can perform assessments and service quickly.

These transformers connect cleanly to underground power line. They develop a vital web link in between the utility grid and the end-user’s electric system. Typical uses include shopping mall, hogescholen, fabrieken, and workplace parks. They give the needed power step-down successfully. The specific voltage and kVA ranking is chosen based upon the tons requirements. Correct sizing ensures optimal efficiency and durability.

Applications of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Pad installed transformers deal with important power tasks. They tip down greater voltage electrical energy to levels risk-free for everyday use. You see them commonly in communities. They provide power to groups of homes or apartment. These systems prevail. They sit on concrete pads right at ground level. This makes them protected and easy to reach for solution. Their hard steel cases shield the equipment inside from climate and people touching them. They are built for outside use.

Services rely on these transformers also. Winkelcentra maken er gebruik van. Office buildings require them. They supply the appropriate power for lights, computer systems, and machines. Manufacturing facilities set up pad placed transformers. They power heavy devices dependably. Medical facilities depend upon them for important treatment locations. Places requiring constant power pick these systems. They are dependable.

Various sizes exist for different requirements. Smaller systems, like 75kVA or 112.5 kVA, typically serve tiny industrial buildings or a couple of houses. Larger sizes, like 160kVA or 500kVA, deal with larger loads. They power bigger shops, bigger groups of homes, or commercial devices. The voltage issues. Systems rated for 13.2 kV, 23kV, or 35kV link to various power lines located in different locations. Deze flexibiliteit is cruciaal.

Renewable resource jobs use pad installed transformers. Ze koppelen zonneparken of windturbines aan het elektriciteitsnet. The power produced needs transforming. These devices do that work well. They match limited areas conveniently. Their small layout is a big advantage. They maintain the power streaming securely. They are a vital part of the electric system.

Bedrijfsprofiel

PDDN Foto-elektron Technologie Co., Ltd. is een van de toonaangevende ondernemingen op het gebied van vermogenselektronicatechnologie en energieproducten, dat volledig betrokken is bij de ontwikkeling van omvormers voor zonne-energie, transformatoren, spanningsregelaars, verdeelkasten, thyristoren, modules, diodes, verwarmers, en andere elektronische apparaten of halfgeleiders. We zullen ons inzetten om gebruikers hoogwaardige kwaliteit te bieden, efficiënte producten en attente service.

Het accepteert betaling via creditcard, T/T, Westelijke Unie, en PayPal. PDDN verzendt de goederen via FedEx naar klanten in het buitenland, DHL, over zee, of door de lucht. If you want high-quality Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer , Stuur ons alstublieft vragen; wij zullen hier zijn om u te helpen.


Betaalmethoden

L/C, T/T, Western Unie, Paypal, Creditcard enz.


Verzending

Over zee, door de lucht, per expresse, zoals klanten vragen.


Opslagomstandigheden

1) Bewaren in een droge omgeving bij kamertemperatuur.

2) Vermijd vocht en hoge temperaturen.

3) Gebruik onmiddellijk na het openen van de binnenverpakking.

5 FAQs of Pad Mounted Transformer 13.2kV/23kV/35kV 75kVA/112.5kVA/ 160kVA/500kVA Transformer Pad Mounted Transformer

Check your voltage first. Pad mounted transformers handle different primary voltages like 13.2kV, 23kV, of 35kV. You must pick the exact voltage your power line uses. These voltages are not interchangeable. Getting the voltage wrong causes major problems.

How big a transformer do you need? Sizes like 75kVA, 112.5kVA, 160kVA, and 500kVA are common. Choose based on your actual power demand. Don’t guess. Look at your peak electrical load. Picking a transformer too small overloads it. Picking one too big wastes money. Match the kVA rating to your measured load.

Safety matters. These units are built tough. They sit outside near people. Expect strong, fraudebestendige stalen behuizingen. Deuren vergrendelen veilig. Internal designs often resist electrical arcs. Good ventilation prevents overheating. The design keeps the public safe.

Maintenance is usually low. These transformers are sealed units. You don’t service them daily. Routinecontroles zijn essentieel. Zoek naar olielekken. Luister naar ongebruikelijke zoemende geluiden. Check cooling fins aren’t blocked. Monitor the temperature gauges. Houd het gebied rond de transformator vrij. Professional inspections every few years are smart.

Installatie vereist planning. The transformer sits on a solid concrete pad. The pad must be perfectly level. It must support the heavy weight. Leave enough space all around. Workers need room for safe cable connections. Workers need room for future checks. Follow the manufacturer’s spacing rules exactly. Proper clearances prevent accidents.

VRAAG EEN OFFERTE AAN