Soláthraí Comhpháirteanna Leictreonacha | Claochladáin, Ionduchtóirí, Inverters
Paraiméadair TÁIRGÍ
Glacann an comhlacht struchtúr inslithe nua, a fheabhsaíonn an cumas chun seasamh in aghaidh ciorcaid ghearr; Tá an croí iarainn déanta as leatháin chruach sileacain fuar-rollta ardchaighdeáin; Tá an foirceannadh ardvoltais déanta as sreang copar saor ó ocsaigine agus glacann sé struchtúr sorcóireach ilchiseal; Déileáiltear le gach comhábhar daingean le bearta speisialta frithscaoilte.
Cur síos
IARRATAS A CHUID
Cur síos
Reliable Structural Design
- Spiral windings with longitudinal oil channels for enhanced internal heat dissipation.
- Reinforced support at winding ends for increased short-circuit resistance.
- New lifting and positioning structures ensure safe long-distance transport and stable operation.
- Multiple proprietary structural designs deliver higher reliability and performance.
- Advanced engineering ensures superior technological performance across all models.
Premium Material Selection
- Oxygen-free copper wire with low resistivity and smooth, burr-free surface treatment reduces load loss and improves electrical reliability.
- High-quality silicon steel sheets with low unit loss minimize no-load loss.
- Laminated wood insulation components remain intact even under short-circuit conditions.
- Deep-filtered transformer oil with minimal water, gás, and impurity content.
- Durable rubber seals effectively prevent aging and oil leakage.
- All materials undergo strict quality inspection and supplier audits in compliance with ISO9001 standards.
Enhanced Technical & Economic Performance
- Compared to the S9 series, the S11 series offers:
- 30% reduction in average no-load loss
- 70–85% lower no-load current
- 10K lower average temperature rise
- Over double the service life
- Capable of continuous 20% overload operation
- 2–4 dB lower operating noise
Tógáil Séalaithe go hiomlán
- The “M” in model S11(M)R denotes a fully sealed tank design.
- Replaces conventional oil pipes with corrugated fins for heat dissipation, eliminating the need for an external oil conservator.
- Welded corrugated fins, made from high-quality cold-rolled steel, allow oil volume expansion while isolating the interior from the atmosphere.
- This design slows oil aging and prevents moisture absorption, ensuring maintenance-free operation.
- The tank undergoes degreasing, derusting, phosphating, and triple-protection coating, making it suitable for harsh environments such as metallurgical, peitriceimiceach, and mining applications.
Product Standards
Compliant with:
GB 1094.1-1996, GB 1094.2-1996, JB/T10088-2004,
GB 1094.3-2003, GB 1094.5-2003, GB/T 10237-1988,
GB/T 6451-2008, GB/T 7595-1987, JB/T 3837-2010
Operating Conditions
- Standard Conditions
- Altitude ≤ 1000 m
- Teocht Chomhthimpeallach:
- Maximum: +40°C
- Hottest Month Average: +30°C
- Annual Average: +20°C
- Minimum Outdoor: –25°C
- Special Conditions
- Altitude > 1000 m
- Teocht Chomhthimpeallach:
- Maximum: +40°C
- Minimum: –25°C
- Custom requirements available upon consultation at time of order.
IARRATAS A CHUID
Clibeanna
TÁIRGÍ GAOLMHARA

220kv Caillteanas Íseal ola-tumtha 200 Mva Trasfhoirmeoir Cumhachta

Oil Immersed Transformer 400KVA Three-phase Oil Immersed Transformer with 30kv Input Voltage

JLSW3-10 Trasfhoirmeoir Comhcheangailte Ola-tumtha Allamuigh, umar méadraithe

50Trasfhoirmeoir Cumhachta Trí phas atá tumtha le hola KVA

Trasfhoirmeoir Cumhachta Tumtha Ola Allamuigh Ardvoltais 200KVA/400KVA Ionchur Trí Chéim 15KV/6KV 415V/380V le haghaidh Feidhmchláir 208V