Fornitore di componenti elettronici | Trasformatori, Induttori, Invertitori
PARAMETRI DEL PRODOTTO
- Tipo: Trasformatore immerso nell'olio
- Service: Customized Service
- Tensione nominale: 10kV, 35kV
- Funzione: Energy Storage Transformer
- Nature of Business: Manufacturer
Descrizione

Trasformatori immersi in olio specializzati nello stoccaggio dell'energia
Structural Advantages:
1. The transformer core adopts a quasi-circular cross-section, which results in a more compact structure and significantly improved short-circuit withstand capability compared to traditional elongated designs. It successfully passed the short-circuit withstand test at the Shenbei Substation.
2. High-density electrical grade laminated wood is used for transformer core clamping components, creating a more compact overall structure and providing some suppression of stray losses caused by leakage magnetic fields.
3. By altering the internal body positioning and switch installation method, the high-voltage raising platform has been redesigned to have a structure without hand holes, reducing the risk of oil leakage.
Quality Control Advantages:
1. The transformers consider the losses caused by harmonic currents, avoiding exceeding the temperature rise limits of the transformer oil and windings. Additionally, it takes into account the increased capacity demand resulting from harmonic currents to ensure the transformer’s service life.
2. For products of the same model and batch, 10% (>1 unità) are selected for lightning impulse tests and temperature rise tests to further ensure the product’s electrical and mechanical performance.
3. While the national standard GB/T 1094.3 does not specify partial discharge tests for 35kV oil-immersed power transformers, from a product quality perspective, the assessment has been intensified. According to the testing method specified in GB/T 7354, partial discharge tests are conducted on each new energy transformer to ensure that the partial discharge level is <50pC at 1.2Ur and ≤100pC at 1.4Ur (Ur is the rated voltage of the transformer).
Standards Compliance:
GB/T 1094.1 Trasformatori di potenza – Part 1: Generale
GB/T 1094.3 Trasformatori di potenza – Part 3: Insulation Levels, Insulation Tests, and External Clearances in Air
GB/T 1094.5 Trasformatori di potenza – Part 5: Ability to Withstand Short-Circuit
GB/T 1094.14 Trasformatori di potenza – Part 16: Transformers for Wind Turbine Generators
GB/T 6451 Technical Parameters and Requirements for Oil-Immersed Power Transformers
GB20052 Limits and Grades for Energy Efficiency of Power Transformers
IEC60076-20 Power Transformers – Part 20: Efficienza energetica.

Production scene diagram of transformer workshop
RICHIEDI UN PREVENTIVO
PRODOTTI CORRELATI

Trasformatore elettrico a bagno d'olio trifase di distribuzione elettrica di alta qualità con approvazione UL

Trasformatore in olio ad alta tensione con slot per carta Materiali ed elementi isolanti del trasformatore

Trasformatori elettrici a bagno d'olio ad alta capacità Pratica tensione di ingresso trifase 35KV/10KV 50HZ/60HZ MV&Trasformatori AT

45-6800kVA 12kV 15kV 24kV 36kV Ingresso personalizzato Sottostazione compatta con trasformatore elettrico ad alta potenza montato su pad certificato UL

500Trasformatore di potenza a bagno d'olio kv 630kva 3 Conversione di fase ad alta tensione Uscita 220v Ingresso 35kv Compatibile 50Hz 60Hz