Penyimpanan Tenaga Transformer Rendam Minyak Khusus

PARAMETER PRODUK

  • taip: Transformer Rendam Minyak
  • Perkhidmatan: Perkhidmatan Tersuai
  • Voltan Ternilai: 10kV, 35kV
  • Fungsi: Energy Storage Transformer
  • Sifat Perniagaan: Pengeluar
Penerangan
MINTA SEBUT HARGA

Penerangan

Penyimpanan Tenaga Transformer Rendam Minyak Khusus
Penyimpanan Tenaga Transformer Rendam Minyak Khusus

Structural Advantages:

1. The transformer core adopts a quasi-circular cross-section, which results in a more compact structure and significantly improved short-circuit withstand capability compared to traditional elongated designs. It successfully passed the short-circuit withstand test at the Shenbei Substation.

2. High-density electrical grade laminated wood is used for transformer core clamping components, creating a more compact overall structure and providing some suppression of stray losses caused by leakage magnetic fields.

3. By altering the internal body positioning and switch installation method, the high-voltage raising platform has been redesigned to have a structure without hand holes, reducing the risk of oil leakage.

Quality Control Advantages:

1. The transformers consider the losses caused by harmonic currents, avoiding exceeding the temperature rise limits of the transformer oil and windings. Selain itu, it takes into account the increased capacity demand resulting from harmonic currents to ensure the transformer’s service life.

2. For products of the same model and batch, 10% (>1 unit) are selected for lightning impulse tests and temperature rise tests to further ensure the product’s electrical and mechanical performance.

3. While the national standard GB/T 1094.3 does not specify partial discharge tests for 35kV oil-immersed power transformers, from a product quality perspective, the assessment has been intensified. According to the testing method specified in GB/T 7354, partial discharge tests are conducted on each new energy transformer to ensure that the partial discharge level is <50pC at 1.2Ur and ≤100pC at 1.4Ur (Ur is the rated voltage of the transformer).

Pematuhan Piawaian:

GB/T 1094.1 Pengubah Kuasa – Part 1: Umum

GB/T 1094.3 Pengubah Kuasa – Part 3: Insulation Levels, Insulation Tests, and External Clearances in Air

GB/T 1094.5 Pengubah Kuasa – Part 5: Ability to Withstand Short-Circuit

GB/T 1094.14 Pengubah Kuasa – Part 16: Transformers for Wind Turbine Generators

GB/T 6451 Technical Parameters and Requirements for Oil-Immersed Power Transformers

GB20052 Limits and Grades for Energy Efficiency of Power Transformers

IEC60076-20 Power TransformersPart 20: Kecekapan Tenaga.