A comprehensive guide to the selection and technical parameters of dry-type transformers: 10 key points that engineers and procurement are most likely to overlook

In practical projects, the problem of selecting the wrong model for 乾式変圧器 is very common.

The capacity is sufficient, but the temperature rise exceeds the standard;
Voltage matching, but noise is not qualified;
Parameter compliance, but overseas acceptance failed.

This article will delve into the most critical but easily overlooked technical details of dry-type transformers from the perspective of engineering selection.

乾式変圧器
乾式変圧器

1.容量の選択: You cannot just look at kVA

1.1 Continuous load and intermittent load

Dry-type transformers are highly sensitive to ambient temperature and require appropriate derating in the following scenarios:

  • high altitude
  • high temperature environment
  • Closed computer room

1.2 Overload Capacity Assessment

The short-term overload capacity of epoxy cast 乾式変圧器 is significantly weaker than that of oil immersed transformers, and the load curve needs to be evaluated in advance.

2.Voltage level and wiring group

Common combinations:

  • 10kV / 0.4kV
  • 20kV / 0.4kV

The wiring group should match the system protection logic, のような:

  • ダイナ11
  • はい0

3.Insulation level and temperature rise design

絶縁クラスTypical Temperature Rise
クラスF100K
クラスH125K

When choosing, consider long-term operating temperature rather than short-term limits.

4.Selection of cooling method

あん: 自然冷却, 低騒音
の: Forced air cooling, capacity can be increased by 30-40%

But the reliability and maintenance of the fan also need to be taken into consideration.

5.Partial discharge level

High quality dry-type transformers typically require:

  • Partial discharge ≤ 10 パソコン

This is one of the core indicators for overseas project acceptance.

6.Noise control

Noise often becomes a veto in data center and commercial building projects.
Attention should be paid to:

  • core structure
  • Shock absorption design
  • Installation foundation

7.Protection level and environmental adaptability

Common levels:

  • IP00 (indoor)
  • IP23/IP31 (anti drip, anti foreign object)

8.Energy efficiency and loss indicators

Critical loss parameters:

  • 無負荷損失
  • 負荷損失

The EU and North American markets have particularly strict requirements for this.

9.規格, certifications, and documents

Common requirements:

  • IEC / IEEE
  • CE
  • ISO system documents

10Hidden risks of export projects

Wooden crate packaging standard
Shipping moisture prevention
Technical document language

Dry-type transformers are not necessarilythe better the parameter table, the safer it is”, but rather highly coupled system equipment with application scenarios.
The truly professional selection is a comprehensive reflection of technical understanding, engineering experience, and standard awareness.

洛陽大唐能源科技有限公司, 株式会社. Rを統合したハイテク企業です&D, 変圧器などの電力機器の製造・供給, 新しいエネルギー成分, 配電盤とインバータ. 技術革新を核に, 私たちは、世界中の顧客にサービスを提供するために、高信頼性と高性能の電源ソリューションの開発に注力しています。. 厳格な品質管理システムと国際規格認証を取得しています。, これからも優れた製品を世に送り出し、お客様の安全・安定した電力システムの構築をお手伝いします.

ニュースレターの更新情報

以下にメールアドレスを入力してニュースレターを購読してください